Mobile Site Full Version
share:

Guard Cartridges & Hardware

Raptor EXP Guard Column Cartridges

More Details
  • Free-Turn architecture lets you change cartridges by hand without breaking inlet/outlet fluid connectionsno tools needed.
  • Patented titanium hybrid ferrules can be installed repeatedly without compromising high-pressure seal.
  • Auto-adjusting design provides ZDV (zero dead volume) connection to any 10-32 female port.

Force EXP Guard Column Cartridges

More Details
  • Free-Turn architecture lets you change cartridges by hand without breaking inlet/outlet fluid connectionsno tools needed.
  • Patented titanium hybrid ferrules can be installed repeatedly without compromising high-pressure seal.
  • Auto-adjusting design provides ZDV (zero dead volume) connection to any 10-32 female port.

EXP Direct Connect Holder

More Details
  • Free-Turn architecture lets you change cartridges by hand without breaking inlet/outlet fluid connectionsno tools needed.
  • Patented titanium hybrid ferrules can be installed repeatedly without compromising high-pressure seal.
  • Auto-adjusting design provides ZDV (zero dead volume) connection to any 10-32 female port.
  • EXP direct connect holder requires separate guard column cartridges; available from Restek in 2.1, 3.0, and 4.6 mm.

Trident LC Column Protection System

Redesigned to be more rugged and easier to use!

More Details
  • Match your needs with three levels of protection: filter only, cartridge only, or filter and cartridge.
  • Durable metal tip with replaceable PEEK ferrule means easy installation onto column without tools.
  • Improved thread design and materials create an optimal seal that releases and reseals easily, allowing multiple installations without galling and binding.
  • Easy-to-remove cap frit simplifies filter replacement.
  • Direct connection eliminates tubing and connectors that increase system volume and leak potential.
  • Low-dead-volume design has negligible effect on chromatography.

Roc LC Guard Column Cartridges

More Details
  • Protect your Roc LC columns with minimal effect on retention, peak shape, or efficiency.

Roc LC Guard Column Holder

More Details
  • Protect your Roc LC columns with minimal effect on retention, peak shape, or efficiency.
  • Requires separate guard column cartridges (available from Restek).

Ultra Guard Cartridges

More Details
Particle size: 5 µm spherical
Pore size: 100 Å

For a detailed description of the stationary phase in this guard cartridge, see the product page for an analytical column with the same silica and stationary phase (e.g., Ultra C18).

Pinnacle DB Guard Cartridges

More Details
Particle size: 5 µm spherical
Pore size: 140 Å

For a detailed description of the stationary phase in this guard cartridge, see the product page for an analytical column with the same silica and stationary phase (e.g., Pinnacle DB C18).

UltraShield UHPLC PreColumn Filter

More Details
  • Cost-effective protection for UHPLC systems.
  • Reliable way to filter out particulates and extend column lifetime.
  • Minimize extra column volume and maximize UHPLC sample throughput vs. guard cartridges.
  • Universal fitconnects easily to any brand column.
  • Leaktight to 15,000 psi (1,034 bar).
  • 0.5 µm or 0.2 µm stainless steel frit in a stainless steel body with PEEK ferrule.

UltraLine UHPLC In-Line Filter

More Details
  • In-line design installs easily with standard fittings.
  • Cost-effective protection for UHPLC systems.
  • Reliable way to extend column lifetime.
  • Leaktight to 15,000 psi (1,034 bar).
  • Replaceable 0.5 µm stainless steel frit in stainless steel body.

Pinnacle II PAH Guard Cartridges

More Details
Particle size: 4 µm spherical
Pore size: 110 Å

Allure Guard Cartridges

More Details
Particle Size: 5 µm spherical
Pore Size: 60 Å

For a detailed description of the stationary phase in this guard cartridge, see the product page for an analytical column with the same silica and stationary phase (e.g., Allure AK).

Viva Guard Cartridges

More Details
Particle size: 5 µm spherical
Pore size: 300 Å

For a detailed description of the stationary phase in this guard cartridge, see the product page for an analytical column with the same silica and stationary phase (e.g., Viva C18).

Trident HPLC In-Line Guard Cartridge Holders

More Details
A Trident in-line guard cartridge holder can be used with almost any HPLC column by connecting it with a short piece of 1/16" tubing, appropriate nuts and ferrules, or finger-tight fittings. The system can be used with Restek columns, or with columns from other manufacturers. Holders are available for 10 mm guard cartridges. Purchase with or without a prefilter, which provides added protection against the particles that can shorten the lifetime of the guard cartridge.

High-Pressure Frit-Type In-Line Filter

More Details
Restek’s high-pressure in-line filter is a stand-alone version of the Trident column protection system, specifically designed for ease of use, low dead-volume, and flexibility. The filter has a replaceable, PEEK encapsulated 316 stainless steel frit with a surface area of 12 mm2. The standard frit with 2.0 µm porosity may be replaced with an optional 0.5 µm porosity frit. Use of this filter can greatly extend column life, thereby reducing costs and saving maintenance time. Tubing 1/16" OD; connectorsCPI.

Replacement PEEK Ferrules for Roc LC Guard Column Holder

More Details
Replacement PEEK ferrules for use with the Roc LC guard column holder (sold separately).

Replacement Cap Frit Filters for Trident Guard Cartridges

More Details
Replacement guard cartridges can cost as much as an analytical column, so why not protect them, too? The removable cap frit filter in a Trident direct helps prevent clogged cartridges to extend the life of your column, your cartridge, and your budget.

  • Use 2 mm cap frit filters with 1.0–2.1 mm ID analytical columns.
  • Use 4 mm cap frit filters with 3.0–4.6 mm ID analytical columns.