Topaz GC Inlet Liners Page

The next level of True Blue Performance

Welcome
  • Deactivation—unbelievably low breakdown for accurate and precise low-level GC analyses.
  • Reproducibility—unbeatable manufacturing controls and QC testing for superior reliability across compound classes.
  • Productivity—unparalleled cleanliness for maximized GC uptime and lab throughput.

Patented

Topaz Inlet Liners
100% Satisfaction—if your Topaz GC inlet liner doesn't perform
to your expectations, we will replace it or credit your account.
All Topaz inlet liners are produced with proprietary Restek processes and apply some of the tightest testing specifications in the industry. The exceptionally inert Topaz liners analysts want most are in stock now and are guaranteed to deliver outstanding performance that exceeds your expectations.
Overview

Topaz GC inlet liners feature revolutionary technology and inertness to deliver the next level of True Blue Performance:

Deactivation

As the demand for lower detection limits continues to grow, even the smallest amount of activity in your GC inlet liner can cause analyte breakdown and impact your results—tailing peaks, loss of response, and other issues we’ve all experienced. In developing Topaz inlet liners, our chemists created a new deactivation that yields unbelievably low breakdown.

Figure 1: High inertness is important, especially when using wool. Comparatively testing GC inlet liners with wool using highly reactive 2,4-DNP shows that the competition simply can’t compete.

Comparatively testing GC inlet liners image

With deactivated Topaz GC inlet liners, you prevent unwanted chemical interactions and minimize breakdown, which improves your data quality and dependability and reduces instrument downtime. Even for extremely low-level GC analysis of highly sensitive compounds—like 2,4-DNP, carbaryl, endrin, and DDT—these highly inert liners provide high-quality results that you’ll have to see for yourself to believe.

Learn More

Reproducibility

New Topaz GC inlet liners are made under strict manufacturing controls, followed by a battery of industry-specific QC tests, to prove that every lot we produce maintains superior reliability and outstanding inertness across a broad range of compound classes. By ensuring the utmost reproducibility in our liners, we help eliminate frustration and uncertainty in your work.

Figure 2: As shown with the low breakdown of notoriously reactive compounds like endrin and DDT, you can expect the same great results from one lot to the next with Topaz GC inlet liners.

breakdown of notoriously reactive compounds

In the end, we don’t test Topaz inlet liners to exceed method requirements. We don’t test Topaz liners to exceed industry norms. We manufacture and QC test Topaz liners to exceed your expectations and bring you the peace of mind that you can always depend on the quality and consistency of your data.

Learn More

Productivity

Any time spent with your instrument offline—like when changing your GC inlet liner or conditioning it afterward—directly ties to increased cost per analysis and decreased revenue for your lab... and raises the odds of yet another evening at the bench catching up on backlogged work for you. It is imperative to keep running samples as long as possible and, when you do need to perform maintenance, to get back up and running as quickly as possible.

With the stability and inertness of a Topaz GC inlet liner, you can analyze more samples before your data quality declines and you have to stop to replace your liner.

Figure 3: The stability of a Topaz liner shines compared to leading competitors. Breakdown of a reactive compound like endrin starts low and stays low, even after 40 injections.

EndrinBreakdown
Blisterpack

Topaz inlet liners also feature blister packaging developed for superior cleanliness. The cleaner the liner, the less time you spend conditioning after a maintenance changeout.

Greater instrument uptime translates into more samples being run and more profit for your lab. Get it all with the unparalleled stability and cleanliness of Topaz inlet liners.

Turn to the Ultimate in Deactivation, Reproducibility, and Productivity

Give yourself, your lab, and your customers the confidence you need in the data you generate—and the ability to keep your instruments running longer. Order your Topaz GC inlet liners today.

Send me a sample!
Resources

Warm Up Before You Run - Why conditioning your inlet parts after maintenance is good practice

Background noise in a gas chromatography system can be eliminated by conditioning the system prior to sample analysis. In this article, we discuss warm-up procedures and use liners and liner installation to demonstrate the importance of conditioning the system to remove background peaks. Investing a little time in warming-up the system pays big dividends by preventing costly coelutions and avoidable reanalyses.

Liner Anatomy Bench Companion

This handy GC liner selection guide provides easy-to-read, informative comparisons of packing options, geometries, and dimensions, as well as types of injections and how they relate to liner choice. Keep this guide at your fingertips to make finding the right inlet liner a quick and easy decision. (PDF - 0MB)

Topaz GC Inlet Liners Sales Sheet

Topaz GC inlet liners feature revolutionary technology and inertness to deliver the next level of True Blue Performance. Turn to the ultimate in deactivation, reproducibility, and productivity with Topaz inlet liners. (PDF - 4MB)

Topaz GC Inlet Liners Brochure

Topaz GC inlet liners feature revolutionary technology and inertness to deliver the next level of True Blue Performance. Turn to the ultimate in deactivation, reproducibility, and productivity with Topaz inlet liners. (PDF - 5MB)