Mobile Site Full Version
share:

Other Inlet Supplies

Show Filters

Flip Seal Dual Vespel Ring Inlet Seals

Restek Innovation! Patented.

More Details
Reversible Flip Seal Inlet SealSame Cost, Extended Lifetime
  • Reversible, two-sided design allows significantly more analyses than other seals, at the same pricesimply use, flip, then use again!
  • Vespel ring embedded in top and bottom surface eliminates need for a washer.
  • Highly inert gold seals reduce breakdown and adsorption of active compounds, maximizing component transfer to GC column.
  • Very little torque required to make sealreduces operator variability.

Dual Vespel Ring Inlet Seals

Washerless, Leak-Tight Seals for Agilent GCs

More Details
  • Does not require a separate washer.
  • Requires less torque to seal.
  • Does not require retightening of reducing nut after several oven cycles.
  • Extends column lifetime by preventing oxygen from reaching the column.
  • Same price as the regular inlet seals with washers.
  • Gold plating provides enhanced inertness versus stainless steel.

Inlet Maintenance Kit

for Agilent GCs

More Details
  • Includes the most common consumable GC supplies and tools.
  • All parts meet or exceed performance of instrument manufacturer’s parts.
  • Parts list makes reordering easy.

Capillary Column Nuts

for Agilent 5890/6850/6890/7890 GCs

More Details
Available in brass or stainless steel.

Finger-Tight Capillary Column Nuts

More Details
  • Allow wrench-free column installations.
  • Available for standard (1/16") and compact (Agilent-style) ferrules.
  • Made from high-quality stainless steel.

Finger-Tight Capillary Column Nuts

More Details
  • Rapidly tighten without wrenches; avoid stripped threads.
  • Either version can be used with 0.25, 0.32, or 0.53 mm ID columns.

Inlet Wrench

for Agilent 5890/6850/6890 GCs

More Details
  • Use to remove the septum nut and weldments during GC maintenance.
  • Use the smaller end to remove the septum nut.
  • Use the larger end to tighten the split/splitless weldment nut.
  • High-quality stainless steel construction.
  • Meets original equipment performance.

Septum Nuts

for use with Agilent 5890/6850/6890/7890 Split/Splitless Injectors

More Details
  • Needle guide allows easy penetration and prevents septum coring.
  • Manual injection septum nut allows use of 26-gauge needles for on-column injections.
  • Made of high-quality stainless steel.

Septum Nut Removal Tool

for Agilent 5890/6850/6890/7890 GCs

More Details
  • Easily remove the septum nut without touching the heated nutno more burned fingers!
  • Unique, ergonomic handleeasy to grip.
  • Nut remains in tool for quick reattachment.

1/16-Inch Capillary Inlet Adaptor Fitting Kit

Split/Splitless Fitting for Capillary Columns

More Details
  • 1/16-inch split/splitless fitting that accepts standard capillary ferrules.
  • Easier to install capillary columns because the nut protrudes farther from the insulated injection port chamber.
  • Same column insertion depth as the original manufacturer's equipment.
  • Kit includes adaptor fitting, capillary nut, gold plated 0.8 mm ID Dual Vespel Ring Inlet Seal, and one 0.4 mm ID ferrule.

Extended Capillary Column Nuts

for Agilent 5890/6850/6890/7890 GCs

More Details
  • Visible below inlet insulating cup for easy, breakage-free column installation without removing cup.
  • Finger-tight design to allow wrench-free use.
  • Available for standard (1/16") and compact (Agilent-style) ferrules.
  • Made from high-quality stainless steel.
  • Meets or exceeds original manufacturer's performance.

Viton O-Rings

for Shimadzu 17A, 2010, 2014, and 2030 GCs

Dual Vespel Ring Cross-Disk Inlet Seals

for Agilent GCs

More Details
  • Ideal for high-flow split applications >500 mL/min.
  • Washerless, leak-tight seals.

Fixing Nut for Capillary Column

for Split/Splitless Injector on Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL

More Details
Made of high-quality stainless steel.

Silver Seals

for Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL

Injector Adaptors

for PerkinElmer CAP Injector

More Details
  • Made of high-quality stainless steel.
  • Meet or exceed original manufacturer's performance.
  • Siltek-treated version available for increased inertness.

Restek Enhanced Capillary Nut

for Shimadzu 17A, 2010, 2014, and 2030 GCs

More Details
  • Restek’s design eliminates the slot, increasing lifetime and durability.
  • Meets or exceeds original manufacturer's performance.

Viton O-Rings

for PerkinElmer PSS Injector

More Details
Fits 4 mm OD liners.

Silicone O-Rings

for PerkinElmer Auto SYS XL or Clarus 580/680 GCs with CAP Injector

More Details
Fits 6.2 mm OD liners.

Capillary Nut

for Shimadzu 17A, 2010, 2014, and 2030 GCs

More Details
Meets original manufacturer's performance.

Liner Seals

for Bruker/Varian 1078/1079 GCs

Inlet Liner Seals

for Bruker/Varian 1177 Injectors

More Details
Meets or exceeds original manufacturer’s performance.

Graphite Sealing Ring

for Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL instruments; fits 8 mm OD liners

Siltek Treated Inlet Support Springs

for Bruker/Varian 1075/1077 Split Injectors

More Details
Siltek treated to eliminate sample adsorption.

Capillary Nuts

for Bruker/Varian GCs

More Details
Choose brass or stainless steel construction.

MS Interface Nut

for Thermo Scientific ISQ

More Details
1/16" x 1.2 mm hole (extended). Made of high-quality, nickel-plated brass.

Oven Shrouds

for Agilent 6890/7890 GCs

More Details
  • Includes heating coil and oven temperature sensor.
  • Available in 120 V and 220 V units.

Dual Vespel Ring Inlet Seals

Washerless, Leak-Tight Seals for Thermo TRACE 1300/1310 GCs

More Details
  • Does not require a separate washer.
  • Requires less torque to seal.
  • Does not require retightening of reducing nut after several oven cycles.
  • Extends column lifetime by preventing oxygen from reaching the column.
  • Same price as the regular inlet seals with washers.
  • Gold plating provides enhanced inertness versus stainless steel.

Viton O-Rings

For Agilent, Thermo TRACE 1300/1310, and Varian 1177 GCs

More Details
Fit split (6.3 mm OD) or splitless (6.5 mm OD) liners.

Cross-Disk Inlet Seals

for Thermo TRACE 1300/1310 GCs

More Details
All seals include washers. Ideal for high-flow split applications.

Replacement Inlet Seals

for Thermo TRACE 1300/1310 GCs

More Details
  • Gold plating provides inertness similar to fused silica.
  • All seals include washers.

Heater Block

for Agilent 6850/6890/7890 GC Split/Splitless Injector

More Details
Meets or exceeds original manufacturer’s performance.

Accessories

for ATAS LINEX DMI System

PTV Inlet Adaptor Kit

for Gerstel CIS 3 and CIS 4 PTV Inlets

More Details
  • Meets original manufacturer's performance.
  • Includes inlet adaptor, silver PTV seal, and slotted capillary nut.

Inlet Adaptor Kit for Dual Column Installation

for Agilent Capillary Injectors (Split/Splitless Fitting for Capillary Columns)

More Details
  • 1/16-inch split/splitless fitting that accepts standard, two-hole capillary ferrules.
  • Easier to install capillary columns due to the nut protruding farther from the insulated injection port chamber.
  • Same column insertion depth as the original manufacturer's equipment.
  • Kit includes adaptor fitting, 1/16" capillary nut, gold-plated 1.2 mm ID dual Vespel ring inlet seal, one 0.4 mm ID two-hole ferrule, and one 0.5 mm ID two-hole ferrule.

Hot Swap Capillary Column Nuts

for Agilent GCs

More Details
  • No more burned fingers!
  • No more downtime waiting for injector parts to cool down.

The Claw and The Claw Holder Kit

More Details
  • Easily removes hot liners from injection ports.
  • 4 mL vials (not included) can be replaced when dirty.

Gold-Plated Liner Cap

for Split/Splitless Injector on Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL

Nut for Terminal Fitting

for Thermo Scientific TRACE GCs

Septum Cap

for Split/Splitless Injector on Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL

Make Life Easier (MLE) Capillary Tool Kit

for PerkinElmer GCs

More Details
Everything you need in one complete kit!

Make Life Easier (MLE) Capillary Tool Kit

for Bruker/Varian GCs

More Details
Everything you need in one complete kit!

Make Life Easier (MLE) Capillary Tool Kit

for Thermo Scientific GCs

More Details
Everything you need in one complete kit!

Make Life Easier (MLE) Capillary Tool Kit

for Shimadzu GCs

More Details
Everything you need in one complete kit!

Make Life Easier (MLE) Capillary Tool Kit

for Agilent GCs

More Details
Everything you need in one complete kit!

Replacement Viton O-Rings

for use with the Agilent Flip Top Inlet Sealing System

Capillary Installation Gauge

for Shimadzu 17A, 2010, 2014, and 2030 GCs

More Details
  • Seats ferrule* onto column for consistent installations.
  • Prevents crushed column ends.
  • Made from high-quality stainless steel.

Capillary Installation Gauge

for Bruker/Varian GCs for use with 1/16" ferrules

More Details
  • Seats ferrule* onto column for consistent installations.
  • Prevents crushed column ends.
  • Made from high-quality stainless steel.

Liner Cap Removing Tool

for Thermo Scientific GCs: Focus GC, TRACE GC Ultra & TRACE GC x GC

More Details
  • Easily loosens the liner cap from the injector.
  • Unique, ergonomic handleeasy to grip.

Adapters for Capillary Columns

for Thermo Scientific TRACE & Focus SSL

More Details
  • Use same installation distance as manufacturer's adaptors.
  • Made of high-quality stainless steel.
  • Siltek-treated version available for additional inertness.

Capillary Installation Gauge

for Thermo Scientific TRACE & Focus SSL (M4 Ferrules)

More Details
  • Seats ferrule* onto column for consistent installations.
  • Prevents crushed column ends.
  • Made from high-quality stainless steel.

Heater Block Retaining Nuts

for Agilent GC Split/Splitless Injectors

More Details
  • Aluminum construction.
  • Meet or exceed manufacturer's performance.

EPC Test Kit

for Agilent 6890 GCs

More Details
Kit includes three O-rings, two plugs, one mounting screw, and one test block.

Graphite O-Rings

for Shimadzu 2010, 2014, and 2030 GCs

Septum Nut

for Shimadzu 17A, 2010, 2014, and 2030 GCs

More Details
  • One-piece design for ease of installation and removal.
  • Made of clear anodized aluminum and high-quality stainless steel.

Graphite O-Rings

for PerkinElmer Auto SYS XL or Clarus 580/680 GCs with PSS Injector

More Details
Fits 4 mm OD liners.

Inlet Wrench

for Shimadzu 17A, 2010, 2014, and 2030 GCs

More Details
  • Designed specifically for removing Shimadzu injection ports.
  • High-quality stainless steel construction.

Heat Sink

for Agilent 5890 GC Split/Splitless Injector

More Details
Meets or exceeds original manufacturer’s performance.

Viton O-Rings

for Apex Liners

Liner Seals

for CIS4 and PTV

Heater Cartridge & Platinum Resistance Thermometer (PRT) Sensor

for Agilent 5890 GCs

More Details
  • Use with 5890 FID and split/splitless weldments.
  • Meets or exceeds original manufacturer's performance.

Capillary Installation Gauge

for Agilent 5973/5975/5977 MS

More Details
  • Seats ferrules onto column for consistent installations.
  • Made from high-quality stainless steel.

    Note: Do not use on a 5975/5977 MS with an EI source (inert or SS). Doing so will extend the column too far into the ion source. This installation gauge is compatible with the 5975 MS with a CI source and the 5977 MS with the extractor or high-efficiency sources.

Injection Port Repair Tool

for Agilent Split/Splitless Injection Ports

More Details
  • Remove contaminants, achieve a better seal.
  • Cleans critical inlet seal areas.

Inlet Liner Seals

for Thermo Scientific TRACE PTV

Rethreading Tool

for Agilent Split/Splitless Injection Ports

More Details
Worn and damaged threads can allow oxygen into the systemcompromising analytical results and destroying columns. The built-in guide helps prevent cross-threading.

Inlet Liner Packing Tool

More Details
  • Position wool reproducibly every time.
  • Accurate to a specific, measured depth.
  • Can be used with all manufacturers' liners.

Inlet Liner Removal Tool

More Details
  • Easily remove liner from injectorno more burned fingers.
  • Made from high-temperature silicone.
  • Won’t chip or crack the liner.

Capillary Installation Gauge

for Agilent GCs

More Details
  • Seats graphite* ferrules onto column for consistent installations.
  • Prevents crushed column ends.
  • Made from high-quality stainless steel.

CarboFrit Puller/Inserter Tool

More Details
  • Hook end for removing CarboFrit inserts.
  • Bent end (90°) for inserting CarboFrit inserts.

Backpressure Gas Regulator

More Details
Capillary GC inlet systems have backpressure regulators to maintain a constant upstream pressure and rapidly respond to catastrophic leaks. The 060 psig (0-414 kPa) operating range is sufficient to operate a 105 m, 0.25 mm ID column at its optimum flow rate.

Injector Nut Kit

for Shimadzu 17A, 2010, 2014, and 2030 GCs

More Details
Includes 17A injector nut, 0.4 mm graphite ferrule, and 1/16-inch stainless steel capillary nut.

Graphite O-Rings

for Agilent and Bruker/Varian 1177 Injectors

More Details
Excellent thermal stability at injection port temperatures up to 450 °C!

Injector/Detector Plug Nuts

More Details
  • Use to cap off an injector to isolate leaks.
  • Use to cap off a detector for thermal cleaning.
  • Use to check a detector or make-up gas flow rate.
  • Use to cap off a detector and prevent hydrogen from accidentally diffusing into the oven from an unused detector base.

Siltek Septum Packed Purge Port Weldment

for Agilent 5890 GCs

More Details
Siltek treatment makes weldment inert and eliminates adsorption of sensitive compounds (e.g., DDT and Endrin). Order Viton O-rings and appropriate septa separately.

1/8-Inch Capillary Inlet Adaptor Fitting Kit

Split/Splitless Fitting for 0.53 mm ID Capillary Columns

More Details
  • 1/8-inch split/splitless fitting accepts standard two-hole capillary ferrules and a standard 1/8-inch nut.
  • Makes column installation easy due to the nut protruding farther from the insulated injection port chamber.
  • The column insertion depth is the same as the original equipment.
  • Kit includes adaptor fitting, capillary nut, stainless steel inlet seal, washer, and one 0.8 mm ID two-hole ferrule.
  • Use recessed taper liners with this adaptor.

Direct Replacement Reducing Nut

for Agilent 5890/6850/6890/7890 GCs

More Details
  • Made from high-quality stainless steel.
  • Meets original manufacturer's equipment performance.

Replacement Chemical Traps and Parts

for Agilent GCs

More Details
  • Easy to install.
  • Attach to same fittings as original manufacturer's equipment.

60 psig Backpressure Regulator Kit

for Agilent GCs

More Details
Increase the versatility of your Agilent 5890 GC by replacing the existing 30 psig (207 kPa) backpressure regulator and gauge with our 60 psig (414 kPa) regulator. Enables you to use longer 60 m and 105 m columns as well as shorter 10 m columns. Includes complete instructions.

Cross-Disk Inlet Seals

for Agilent GCs

More Details
  • Ideal for high-flow split applications >500 mL/min on Agilent 5890 GCs.
  • Gold plating provides enhanced inertness versus stainless steel.
  • All seals include washers.

Replacement Inlet Seals

for Agilent GCs

More Details
  • Gold plating provides enhanced inertness versus stainless steel.
  • All seals include washers.

Mini Wool Puller/Inserter

More Details
Insert and remove wool plugs easily. Order a spare pack so you’ll always have one available.

Septum Puller

More Details
  • Use hooked end for removing septa and O-rings; pointed end works well for removing stuck ferrules or debris.
  • Keep several on hand in your laboratory for other uses, too.

PTV Liner Seal Pre-Seat Tool

for Gerstel CIS 3 and CIS 4 PTV Inlets

PTV Slotted Capillary Column Nut

for Gerstel CIS 3 and CIS 4 PTV Inlets

Replacement Parts for Injection Port Repair Tool

for Agilent Split/Splitless Injection Ports

Silver PTV Seals

for Agilent 6890 GCs

Septa Holder Kits

for Thermo Scientific TRACE, 8000, 8000 TOP & Focus SSL

More Details
  • Includes septum support and holder.
  • Made from high-quality stainless steel.
  • Silcosteel-AC-treated version helps with septum removal.