Mobile Site Full Version
share:

Packed/Micropacked Column Inlet Supplies

Packed Column Inlet Adaptor Kit for 1/4" Injection Ports

More Details
  • Use 1/8" and 3/16" OD columns in 1/4" on-column injection ports.
  • Centers column perfectly in injection port to eliminate bent syringe needles.
  • Slotted design prevents carrier gas occlusion.
  • Vespel/graphite reducing ferrules make installation easy.
  • Includes all nuts & ferrules used to attach tubing to the injector or detector.

Micropacked Inlet Conversion Kits

More Details
  • Convert a capillary GC split/splitless inlet for use with 1/16" OD micropacked columns.
  • For use with Agilent 5890, 6890, and 7890 GCs.
  • Sample pathways deactivated for ultimate inertness.

Uniliner Liner

for 1/4-Inch Packed Injection Port Conversion

More Details
  • Reduces solvent tailing.
  • Versatile0.53 mm ID version can be used in the direct (DI) or on-column (OC) injection mode.
  • Incorporates a gentle taper that seals the column and reduces dead volume in direct injection mode.
  • Available in various designs.

Vu-Tight Installation Fittings Kit

More Details
Includes a 1/4-inch stainless steel nut and graphite ferrule for attaching the liner to the GC inlet and a 1/4 to 1/16-inch stainless steel reducer, plus a 1/4-inch and 0.5 mm ID graphite ferrule for attaching the column to the liner.

Dual Column mini-Lam Direct Injection Tee Kit

for 1/4-inch packed column inlets

More Details
  • Inverted cup design offers complete sample vaporization.
  • Permits larger sample volumes.
  • Incorporates a Press-Tight taper in each outlet leg, to make a perfect, dead-volume-free connection to each analytical column (ODs ranging from 0.4 to 0.8 mm).
  • Allows visual confirmation of the column connection.
  • Open-top design makes it easy to pack with glass wool, keeping sample residue from contaminating the cup.

Cyclo Vu-Tight DI Liners, 1/4-inch OD

More Details
  • Visually observe the Press-Tight connection between the column end and liner.
  • Fit 0.32 and 0.53 mm ID capillary columns (column ODs from 0.5 mm to 0.8 mm).
  • Slotted top prevents obstruction of carrier gas flow.
  • Operate in the direct injection mode.

Vu-Tight DI Liners

for 1/4-Inch Packed Injection Port Conversion

More Details
  • Visually observe the Press-Tight connection between the column end and liner.
  • Fit 0.32 and 0.53 mm ID capillary columns (column ODs from 0.5 mm to 0.8 mm).
  • Slotted top prevents obstruction of carrier gas flow.
  • Operate in the direct injection mode.

DI Liner Adaptor

for Agilent 5890 Packed Column GC

More Details
  • Uses standard 1/16-inch capillary nut and ferrules.
  • Convenient wrench pad at base.
  • Includes 1/4-inch graphite ferrule and stainless steel nut.
  • Use with Agilent or Restek DI glass inserts or Restek DI Uniliner liners for an Agilent 5890 packed column GC.

DI Uniliner Liners

for Agilent 5890 Packed Column GC

More Details
  • Press-Tight taper forms dead volume free connection to column.
  • Minimizes solvent and peak tailing.
  • Use with 0.25, 0.32, and 0.53 mm ID capillary columns.
  • Can be removed from the septum nut weldment.

DI Glass Inserts

for Agilent 5890 Packed Column GC

More Details
  • Tolerances closely controlled.
  • Can be removed from the septum nut weldment.

Dual Column Direct Injection Tee Kit

for 1/4-inch packed column inlets

More Details
  • Designed with a glass spiral to promote sample vaporization and provide even sample distribution to the two columns.
  • Traps sample residue and minimizes the need for guard columns.
  • Press-Tight taper in each outlet leg facilitates a perfect dead-volume-free connection to each analytical column (OD 0.4 to 0.8 mm) and allows visual confirmation of the column connection.