ASTM Petrochemical Method Chromatography Product Guide

Proven, Integrated Solutions and Veteran
Expertise for Your Petrochemical &
Chemical Analyses

Restek is your ideal partner for integrated petrochemical solutions, and the following ASTM method product guide will help you quickly pick the right GC columns and reference standards for SimDist, DHA, finished gasoline, and other common petroleum analyses.

If you have any questions or need more information, visit www.restek.com/petro for additional resources or to contact one of our in-house petroleum experts for assistance.

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

(High-Temperature) Simulated Distillation (SimDist)

D2887

Standard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5–C44)

MXT-2887, Siltek-treated stainless steel
10 m x 0.53 mm x 2.65 µm
- cat.# 70199

or

MXT-1HT SimDist, Siltek-treated stainless steel
10 m x 0.53 mm x 2.65 µm
- cat.# 70132

ASTM D2887-12 Calibration Standards
- cat.# 31674
- cat.# 31675

Polywax Standards
- cat.# 36224–36227

D2887 Calibration Mix
- cat.# 31222

D7213

Standard Test Method for Boiling Range Distribution of Petroleum Distillates in the Boiling Range from 100 to 615 °C by Gas Chromatography (C5–C60)

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
- cat.# 70112

or

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
- cat.# 70115

or

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.88 µm
- cat.# 70131

Request today

D6352

Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700 °C by Gas Chromatography (C10–C90)

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
- cat.# 70112

or

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
- cat.# 70115

Polywax Standards
- cat.# 36224–36227

D7398

Standard Test Method for Boiling Range Distribution of Fatty Acid Methyl Esters (FAME) in the Boiling Range from 100 to
615 °C by Gas Chromatography

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.88 µm
- cat.# 70131

Polywax Standards
- cat.# 36224–36227

D7500

Standard Test Method for Determination of Boiling Range Distribution of Distillates and Lubricating Base Oils in Boiling Range from 100 to 735 °C by Gas Chromatography (C7–C110)

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
- cat.# 70112

or

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
- cat.# 70115

Polywax Standards
- cat.# 36224–36227

D7169

Standard Test Method for Boiling Point Distribution of Samples With Residues Such as Crude Oils and Atmospheric and Vacuum Residues by High-Temperature Gas Chromatography

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.10 µm
- cat.# 70112

or

MXT-1HT SimDist, Siltek-treated stainless steel
5 m x 0.53 mm x 0.20 µm
- cat.# 70115

Polywax Standards
- cat.# 36224–36227

D7096

(replaces D3710)

Standard Test Method for Determination of the Boiling Range Distribution of Gasoline by Wide-Bore Capillary Gas Chromatography

MXT-1, Siltek-treated stainless steel
15 m x 0.53 mm x 5.00 µm
- cat.# 70177

or

MXT-1, Siltek-treated stainless steel
30 m x 0.53 mm x 5.00 µm
- cat.# 70179

Request today

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Detailed Hydrocarbon Analysis (DHA)

D5134

Standard Test Method for Detailed Analysis of Petroleum Naphthas through n-Nonane by Capillary Gas Chromatography

Rtx-DHA-50
50 m x 0.20 mm x 0.50 µm
- cat.# 10147

Request today

D6729

Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100-Meter Capillary High-Resolution Gas Chromatography

Rtx-DHA-100
100 m x 0.25 mm x 0.50 µm
- cat.# 10148

DHA Standards
- cat.# 33034
- cat.# 30725–30731

D6730

Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100–Meter Capillary (with pre-column) High-Resolution Gas Chromatography

Rtx-DHA-100
100 m x 0.25 mm x 0.50 µm
- cat.# 10148

and

Rtx-5 DHA Tuning
5 m x 0.25 mm x 1.00 µm
- cat.# 10165

DHA Standards
- cat.# 33034
- cat.# 30725–30731

D6733

Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 50-Meter Capillary High-Resolution Gas Chromatography

Rtx-DHA-50
50 m x 0.20 mm x 0.50 µm
- cat.# 10147

DHA Standards
- cat.# 33034
- cat.# 30725–30731

D5501

Standard Test Method for Determination of Ethanol Content of Denatured Fuel Ethanol by Gas Chromatography

Rtx-DHA-150
150 m x 0.25 mm x 1.00 µm
- cat.# 10149

Request today

Finished Gasoline

D3606

Standard Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline by Gas Chromatography

D3606 Application 2-Column Set
- cat.# 83606—

Specified in the D3606 method addendum - includes:

- Rtx-1
6' (1.8 m), 1/8" OD, 2.0 mm ID

and

- proprietary packing
16' (4.9 m), 1/8" OD, 2.0 mm ID

D3606 Standards
- cat.# 30647–30674

D4815

Standard Test Method for Determination of MTBE, ETBE, TAME, DIPE, tertiary-Amyl Alcohol, and C1 to C4 Alcohols in Gasoline by Gas Chromatography (Oxygenates)

Micropacked with 20% TCEP on 80/100 Chromosorb PAW
0.56 m x 0.75 mm ID x 1/16" OD
- cat.# 19040

and

Rtx-1
30 m x 0.53 mm x 3.00 µm
- cat.# 10185

Request today

D5580

Standard Test Method for Determination of Benzene, Toluene, Ethylbenzene, p/m-Xylene, o-Xylene, C9 and Heavier Aromatics, and Total Aromatics in Finished Gasoline by Gas Chromatography

Micropacked with 20% TCEP on 80/100 Chromosorb PAW
0.56 m x 0.75 mm ID x 1/16" OD
- cat.# 19040

and

Rtx-1
30 m x 0.53 mm x 5.00 µm
- cat.# 10179

Request today

Method #

Method Title

Restek Column(s)

Restek Reference
Standard(s)

Biodiesel

D6584

Test Method for Determination of Free and Total Glycerin in B-100 Biodiesel Methyl Esters by Gas Chromatography

MXT-Biodiesel TG
14 m x 0.53 mm x 0.16 µm
with 2 m Integra-Gap
- cat.# 70289

or

MXT-Biodiesel TG, Siltek-treated stainless steel
10 m x 0.32 mm x 0.10 µm
with 2 m x 0.53 mm retention gap
- cat.# 70290

or

Rtx-Biodiesel TG
10 m x 0.32 mm x 0.10 µm
with 2 m x 0.53 mm retention gap
- cat.# 10291

Biodiesel Standards
- cat.# 31880
- cat.# 33020–33026
- cat.# 33032–33033

Natural Gas

D1945

Standard Test Method for Analysis of Natural Gas by Gas Chromatography

MXT-Msieve 5A, Siltek-treated stainless steel
30 m x 0.53 mm x 50 µm
- cat.# 79723-273

and

MXT-Q-BOND, Siltek-treated stainless steel
30 m x 0.53 mm x 20 µm
- cat.# 79716-273

Natural Gas Standards
- cat.# 34438–34440

Refinery Gas

D2163

Standard Test Method for Determination of Hydrocarbons in Liquefied Petroleum (LP) Gases and Propane/Propene Mixtures by Gas Chromatography

Rt-Alumina BOND/Na2SO4
50 m x 0.53 mm x 10 µm
- cat.# 19756

Refinery Gas Standards
- cat.# 34441–34443

D1946

(UOP 539)

Standard Practice for Analysis of Reformed Gas by Gas Chromatography

2abc Refinery Gas Packed Column Set
- cat.# 88000-875

or

MXT-Msieve 5A, Siltek-treated stainless steel
30 m x 0.53 mm x 50 µm
- cat.# 79723-273

and

MXT-Q-BOND, Siltek-treated stainless steel
30 m x 0.53 mm x 20 µm
- cat.# 79716

Request today

Impurities

D2593

Standard Test Method for Butadiene Purity and Hydrocarbon Impurities by Gas Chromatography

Rt-Alumina BOND/MAPD
50 m x 0.53 mm x 10 µm
- cat.# 19778

Refinery Gas Standard #5
- cat.# 34443

D2712

Standard Test Method for Hydrocarbon Traces in Propylene Concentrates by Gas Chromatography

Rt-Alumina BOND/Na2SO4
50 m x 0.53 mm x 10 µm
- cat.# 19756

Refinery Gas Standard #5
- cat.# 34443

D6159

Standard Test Method for Determination of Hydrocarbon Impurities in Ethylene by Gas Chromatography

Rt-Alumina BOND/KCl
50 m x 0.53 mm x 10 µm
- cat.# 19760

and

Rtx-1
30 m x 0.53 mm x 5.00 µm
- cat.# 10179

Refinery Gas Standard #5
- cat.# 34443

Sulfur

D6228

Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Flame Photometric Detection

Rtx-1
60 m x 0.53 mm x 7.00 µm
- cat.# 10193

or

MXT--1, Siltek-treated stainless steel
60 m x 0.53 mm x 7.00 µm
- cat.# 70193

Request today

D5623

Standard Test Method for Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection

Rtx-1
30 m x 0.32 mm x 4.00 µm
- cat.# 10198

Request today


If you have any questions about Restek Refined or need more information, visit www.restek.com/petro for additional resources or to contact one of our in-house petroleum experts for assistance.