Fused Silica Capillary

Rxi-5Sil MS Columns (fused silica)

low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane

More Details
  • Engineered to be a low-bleed GC-MS column.
  • Excellent inertness for active compounds.
  • General-purpose columnsideal for GC-MS analysis of semivolatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons.
  • Temperature range: -60 °C to 350 °C.

Rxi-5ms Columns (fused silica)

low-polarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General-purpose columns for semivolatiles, phenols, amines, residual solvents, drugs of abuse, pesticides, PCB congeners (e.g., Aroclor mixes), solvent impurities.
  • Most inert column on the market.
  • Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
  • Temperature range: -60 °C to 330/350 °C.
  • Equivalent to USP G27 and G36 phases.

Rxi-1ms Columns (fused silica)

nonpolar phase; Crossbond dimethyl polysiloxane

More Details
  • General-purpose columns for arson accelerants, essential oils, hydrocarbons, pesticides, PCB congeners (e.g., Aroclor mixes), sulfur compounds, amines, solvent impurities, simulated distillation, oxygenates, gasoline range organics (GRO), refinery gases.
  • Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
  • Temperature range: -60 °C to 330/350 °C.
  • Equivalent to USP G1, G2, and G38 phases.

Stabilwax Columns (fused silica)

polar phase; Crossbond polyethylene glycol

More Details
  • Low-bleed PEG column ensures long column lifetimes.
  • Temperature range: 40 °C to 260 °C.
  • Equivalent to USP G14, G15, G16, G20, and G39 phases.

Rxi-624Sil MS Columns (fused silica)

midpolarity Crossbond phase

More Details
  • Low-bleed, high-thermal stability columnmaximum temperatures up to 300320 °C.
  • Inertexcellent peak shape for a wide range of compounds.
  • SelectiveG43 phase highly selective for volatile organics and residual solvents, great choice for USP<467>.
  • Manufactured for column-to-column reproducibilitywell suited for validated methods.

Rxi-17Sil MS Columns (fused silica)

midpolarity Crossbond phase

More Details
  • Excellent inertness and selectivity for active environmental compounds, such as PAHs.
  • Low bleed for use with sensitive detectors, such as MS.
  • 340/360 °C upper temperature limits.
  • Equivalent to USP phase G3.

Rt-2560 Column (fused silica)

highly polar phase; biscyanopropyl polysiloxanenot bonded

More Details
  • Stationary phase selectivity optimized for isomer separation to ensure accurate quantification of critical cis/trans FAMEs.
  • Application-specific QC test guarantees consistent, reliable performance for AOAC 996.06 and AOCS Ce 1j-07 methods.
  • Excellent sample capacity; no peak distortion means easy, accurate peak integration.
  • Temperature range: 20–250 °C.

Rtx-DHA Columns (fused silica)

Crossbond 100% dimethyl polysiloxaneoptimized for hydrocarbon analysis

More Details
  • Columns meet or exceed all ASTM D6730-01 and CAN/CGSB 3.0 No. 14.3-99 method guidelines; test report for method D6730 supplied with each column.
  • Excellent responses and peak symmetry for polar oxygenates.
  • Stable to 340 °C.

Rtx-Biodiesel TG Columns (fused silica)

More Details
  • Linearity for all reference compounds exceeds method requirements.
  • Columns with retention gaps feature Alumaseal connectors to prevent leaks and extend column life.
  • Low column bleed at high temperatures.
  • For glycerin and glycerides analysis, according to ASTM D6584 and EN 14105 methods.
  • Stable to 350 °C.

Stabilwax-DA Columns (fused silica)

polar phase; Crossbond acid-deactivated Carbowax polyethylene glycolfor acidic compounds

More Details
  • Application-specific columns for free (underivatized) acids, some inorganic acids.
  • Resistant to oxidative damage.
  • Equivalent to USP G25, G35 phases.
  • Ideal for analyzing distilled liquor and other alcoholic beverages.

Stabilwax-DB Columns (fused silica)

polar phase; Crossbond base-deactivated Carbowax polyethylene glycolfor amines and basic compounds

More Details
  • Application-specific columns for underivatized amines and other basic compounds, including alkylamines, diamines, triamines, nitrogen-containing heterocyclics. No need for column priming.
  • Temperature range: 40 °C to 220 °C.

Rxi Guard/Retention Gap Columns (fused silica)

More Details
  • Extend column lifetime.
  • Excellent inertnessobtain lower detection limits for active compounds.
  • Sharper chromatographic peaks by utilizing retention gap technology.
  • Maximum temperature: 360 °C.

Rtx-BAC Plus 1 Columns (fused silica)

More Details
  • Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences.
  • Robust and reproducible column chemistry ensures longer column lifetime and consistent results.
  • Stable to 260 °C.

Rtx-BAC Plus 2 Columns (fused silica)

More Details
  • Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences.
  • Robust and reproducible column chemistry ensures longer column lifetime and consistent results.
  • Stable to 260 °C.

Innovative Integra-Guard Columns

Get the protection without the connection!

More Details
  • These innovative columns incorporate both guard column and analytical column in a continuous length of tubing, eliminating the connection and all connection-associated problems!
  • The guard column section is marked separately from the analytical column, using high-temperature string.
  • A wide variety of our Integra-Guard capillary columns are available.

Rxi-PAH Columns (fused silica)

midpolarity proprietary phase

More Details
  • Ideal for EFSA PAH4 analysisseparates all priority compounds: benz[a]anthracene, chrysene, benzo[b]fluoranthene, and benzo[a]pyrene.
  • Best resolution of chrysene from interfering PAHs, triphenylene, and cyclopenta[cd]pyrene.
  • Complete separation of benzo [b], [k], [ j], and [a] fluoranthenes.
  • 360 °C thermal stability allows analysis of low-volatility dibenzo pyrenes.

Rxi-5HT Columns (fused silica)

low-polarity phase; diphenyl dimethyl polysiloxane

More Details
  • Columns processed for high-temperature applications, such as mineral oil.
  • Temperature range: -60 to 400 °C.

Rxi-35Sil MS Columns (fused silica)

midpolarity Crossbond phase

More Details
  • Special selectivity and excellent inertness for substituted polar compounds, such as drugs, pesticides, herbicides, PCBs, phenols, etc.
  • Provides superior separation for cannabinoids.
  • Very low-bleed phase for GC-MS analysis.
  • Extended temperature range: 50 °C up to 360 °C.

Rxi-1301Sil MS Columns (fused silica)

midpolarity Crossbond phase

More Details
  • Highest thermal stability in the industry ensures dependable, accurate MS results and increased uptime.
  • Stabilized cyano phase selectivity improves the performance of existing methods. Ideal for solvents, glycols, and other polar compounds.
  • Rigorous QC testing ensures inertness and accurate, reliable data for multiple compound classes.
  • Maximum temperature: 320 °C.

Stabilwax-MS Columns (fused silica)

More Details
  • High-polarity, stable polyethylene glycol (PEG) stationary phase.
  • Low bleed and rugged enough to withstand repeated temperature cycles without retention time shifting.
  • Ideal for food, flavor, fragrance, and industrial chemical and solvent analysis.
  • Temperature range: 40 °C to 250/260 °C.
  • Equivalent to USP G14, G15, G16, G20, and G39 phases.

GCxGC Selectivity Kit, 0.25 mm

More Details
  • Wide range of stationary phases offers orthogonal separations.
  • High thermal stability increases system ruggedness.
  • Unrivaled column inertness for accurate analysis of active compounds.
  • 0.15, 0.18, or 0.25 mm ID formats accommodate varying sample capacities, speeds, and detectors.
  • Secondary columns come in convenient 2 m lengths for economical methods development.

GCxGC Selectivity Kit, 0.18 mm

More Details
  • Wide range of stationary phases offers orthogonal separations.
  • High thermal stability increases system ruggedness.
  • Unrivaled column inertness for accurate analysis of active compounds.
  • 0.15, 0.18, or 0.25 mm ID formats accommodate varying sample capacities, speeds, and detectors.
  • Secondary columns come in convenient 2 m lengths for economical methods development.

GCxGC Selectivity Kit, 0.15 mm

More Details
  • Wide range of stationary phases offers orthogonal separations.
  • High thermal stability increases system ruggedness.
  • Unrivaled column inertness for accurate analysis of active compounds.
  • 0.15, 0.18, or 0.25 mm ID formats accommodate varying sample capacities, speeds, and detectors.
  • Secondary columns come in convenient 2 m lengths for economical methods development.

Rxi-1HT Columns (fused silica)

nonpolar phase; dimethyl polysiloxane

More Details
  • Columns processed for high-temperature applications, such as high molecular weight hydrocarbons.
  • Temperature range: -60 to 400 °C.

Rtx-5 DHA Tuning Column (fused silica)

Crossbond 5% diphenyl/95% dimethyl polysiloxaneoptimized for hydrocarbon analysis

Rtx-1614 Columns (fused silica)

5% diphenyl, 95% dimethyl polysiloxane

More Details
  • Optimized for PBDE analysis by EPA Method 1614.
  • Short column option resolves BDE-209 3 times faster, with less thermal breakdown.
  • Unique deactivation gives higher BDE-209 response than competitor columns, for greater analytical sensitivity.
  • Exceeds EPA Method 1614 resolution criteria for BDE-49 and BDE-71.
  • Stable to 360 °C.

Rxi-XLB Columns (fused silica)

low-polarity proprietary phase

More Details
  • General-purpose columns exhibiting extremely low bleed. Ideal for many GC-MS applications, including pesticides, PCB congeners (e.g., Aroclor mixes), PAHs.
  • Unique selectivity.
  • Temperature range: 30 °C to 360 °C.

Rtx-CLPesticides Column Kit, 0.32 mm ID

proprietary Crossbond phases

More Details
  • Application-specific columns for organochlorine pesticides and herbicides.
  • Low bleedideal for high sensitivity GC-ECD or GC-MS analyses.
  • Baseline separations in less than 10 minutes.

    Note: Columns are not preconnected in this kit.

Rxi-17 Columns (fused silica)

midpolarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols.
  • Temperature range: 40 °C to 320 °C.

Rtx-PCB Columns (fused silica)

proprietary Crossbond phase

More Details
  • Unique polymer for PCBs analysis by GC-ECD or GC-MS.
  • Good results for other semivolatiles.
  • Low polarity; inert to active compounds.
  • Stable to 340 °C.

Rtx-Dioxin2 Columns (fused silica)

proprietary Crossbond phase

More Details
  • Isomer specificity for 2,3,7,8-TCDD and 2,3,7,8-TCDF achieved with one GC column.
  • Thermally stable to 340 °C for longer lifetime.
  • Unique selectivity for toxic dioxin and furan congeners allows use as a confirmation GC column.

Rtx-OPPesticides2 Columns (fused silica)

proprietary Crossbond phase

More Details
  • Application-specific columns for organophosphorus pesticides; best column combination for U.S. EPA Method 8141.
  • Low bleedideal for GC-FPD, GC-NPD, or GC-MS analyses.
  • Stable to 330 °C.

Rtx-CLPesticides Column Kit, 0.25 mm ID

proprietary Crossbond phases

More Details
  • Application-specific columns for organochlorine pesticides and herbicides.
  • Low bleedideal for high sensitivity GC-ECD or GC-MS analyses.
  • Baseline separations in less than 10 minutes.

    Note: Columns are not preconnected in this kit.

Rtx-CLPesticides Column Kit, 0.53 mm ID

proprietary Crossbond phases

More Details
  • Application-specific columns for organochlorine pesticides and herbicides.
  • Low bleedideal for high sensitivity GC-ECD or GC-MS analyses.
  • Baseline separations in less than 10 minutes.

    Note: Columns are not preconnected in this kit.

Rtx-VMS Columns (fused silica)

proprietary Crossbond phase

More Details
  • Application-specific columns for analyzing volatile organic pollutants by GC-MS including Methods TO-15, TMS, and EPA 8260.
  • Complete separation of U.S. EPA Method 8260 compounds in less than 10 minutes.
  • Stable to 260 °C.
  • No known equivalent phases.

Rtx-CLPesticides2 Columns (fused silica)

proprietary Crossbond phase

More Details
  • Application-specific columns for organochlorine pesticides and herbicides.
  • Low bleedideal for high sensitivity GC-ECD or GC-MS analyses.
  • Baseline separations in less than 10 minutes.
  • Stable to 320340 °C.
  • Analyze EPA Method 8081B, 8082A, 8151A, 504.1, 515, 508.1, and 552.2 compounds without time-consuming column changes.

Rtx-CLPesticides Columns (fused silica)

proprietary Crossbond phase

More Details
  • Application-specific columns for organochlorine pesticides and herbicides.
  • Low bleedideal for high sensitivity GC-ECD or GC-MS analyses.
  • Baseline separations in less than 10 minutes.
  • Stable to 320340 °C.
  • Analyze EPA Method 8081B, 8082A, 8151A, 504.1, 515, 508.1, and 552.2 compounds without time-consuming column changes.

FAMEWAX Columns (USP G16) (fused silica)

polar phase; Crossbond polyethylene glycol

More Details
  • Application-specific columns for FAMEs, specially tested with a FAME mixture.
  • Temperature range: 20 °C to 250 °C.

Rt-CW20M F&F Columns (fused silica)

polar phase; Carbowax polyethylene glycolnot bonded

More Details
  • Application-specific columns for flavor and fragrance compounds, specially tested.
  • True nonbonded Carbowax 20M polarity.
  • Temperature range: 60 °C to 250 °C.

Rtx-65TG Columns (fused silica)

high-polarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • Application-specific columns, specially tested for triglycerides.
  • Stable to 370 °C.

Rt-TCEP Columns (fused silica)

highly polar phase; 1,2,3-tris[2-cyanoethoxy]propanenot bonded

More Details
  • General-purpose columns, ideal for aromatics and oxygenates in gasoline.
  • Temperature range: 0 °C to 150 °C.

Rtx-G43 Column (fused silica with 5-meter Integra-Guard guard column)

Crossbond cyanopropylmethyl phenylmethyl polysiloxane

More Details
  • Application-specific columns for residual solvents in pharmaceutical products. Meet all requirements of USP <467>.
  • Analytical column with Integra-Guard guard column eliminates connecting problems and leaks.
  • Rtx-G43 stable to 240 °C.

Rtx-G27 Column (fused silica with 5-meter Integra-Guard guard column)

Crossbond diphenyl dimethyl polysiloxane

More Details
  • Application-specific columns for residual solvents in pharmaceutical products.
  • Analytical column with Integra-Guard guard column eliminates connecting problems and leaks.
  • Rtx-G27 stable to 290 °C.

Rtx-5 (G27) Columns (fused silica)

low-polarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General-purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles.
  • Equivalent to USP G27 and G36 phases.

Rtx-1 Columns (fused silica)

nonpolar phase; Crossbond dimethyl polysiloxane

More Details
  • General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates.
  • Long lifetime and very low bleed at high operating temperatures.
  • Equivalent to USP G1, G2, G38 phases.

Rxi-XLB Secondary Columns for GCxGC (fused silica)

low polarity proprietary phase

More Details
  • Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses.
  • General purpose columns exhibiting extremely low bleed.
  • Unique selectivity.
  • Temperature range: 30 °C to 360 °C.

Rtx-200 Secondary Columns for GCxGC (fused silica)

midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane

More Details
  • Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses.
  • General purpose column.
  • Temperature range: -20 °C to 340 °C.

Stabilwax Secondary Columns for GCxGC (fused silica)

polar phase; Crossbond polyethylene glycol

More Details
  • Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses.
  • Low-bleed polyethylene glycol (PEG) phase.
  • Temperature range: 40 °C to 260 °C.

Rxi-1ms Secondary Columns for GCxGC (fused silica)

nonpolar phase; Crossbond dimethyl polysiloxane

More Details
  • Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses.
  • General purpose columns.
  • Temperature range: -60 °C to 330/350 °C (bleed tested temperature/maximum operating temperature).

Rxi-5Sil MS Secondary Columns for GCxGC (fused silica)

low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane

More Details
  • Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses.
  • Engineered to be a low bleed GC/MS column.
  • Excellent inertness for active compounds.
  • General purpose columns.
  • Temperature range: -60 °C to 350 °C.

Rxi-17Sil MS Secondary Columns for GCxGC (fused silica)

midpolarity Crossbond phase

More Details
  • Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses.
  • 340/360 °C upper temperature limits.
  • Excellent inertness and selectivity for active environmental compounds, such as PAHs.
  • Low-bleed for use with sensitive detectors, such as MS.

Rtx-Volatile Amine Columns (fused silica)

More Details
  • Unique selectivity for baseline resolution of all volatile amines.
  • Excellent inertness assures accuracy and sensitivity for volatile amines, including free ammonia.
  • Highly robust phase withstands repeated water injections, resulting in longer column lifetime.
  • High temperature stability (290 °C) ensures elution of amines up to C16 and allows contaminants to be removed by “baking out” the column.

Rtx-Mineral Oil Columns (fused silica)

More Details
  • Application specific columns meet DIN EN ISO 9377-2:2000 requirements.
  • Optimized column dimensions for fast mineral oil screening.
  • Surface linked phase guarantees long lifetime, robustness, and stability to 400 °C.

Rtx-440 Columns (fused silica)

midpolarity proprietary Crossbond phase

More Details
  • General-purpose columns with unique selectivity for pesticides, PAHs, or other semivolatiles. Ideal for low/trace-level analyses.
  • Low-bleed, high-resolution columns with unique selectivity.
  • Wide temperature range: 20 °C to 340 °C.

Rtx-35 Amine Columns (fused silica)

midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane

More Details
  • Application-specific columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.

Rtx-624 Columns (fused silica)

low- to midpolarity phase

More Details
  • Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants.
  • Temperature range: -20 °C to 240 °C.
  • Equivalent to USP G43 phase.

Rtx-502.2 Columns (fused silica)

proprietary Crossbond diphenyl/dimethyl polysiloxane phase

More Details
  • Application-specific columns with unique selectivity for volatile organic pollutants. The Rtx-502.2 column is cited in U.S. EPA Method 502.2 and in many gasoline range organics (GRO) methods for monitoring underground storage tanks.
  • Excellent separation of trihalomethanes; ideal polarity for light hydrocarbons and aromatics.
  • Stable to 270 °C.

Rtx-VRX Columns (fused silica)

proprietary Crossbond phase

More Details
  • Application-specific columns for volatile organic pollutants.
  • Excellent for U.S. EPA Method 8021 compounds.
  • Stable to 260 °C.

Rtx-OPPesticides Columns (fused silica)

proprietary Crossbond phase

More Details
  • Application-specific columns for organophosphorus pesticides; best column combination for U.S. EPA Method 8141.
  • Low bleedideal for GC-FPD, GC-NPD, or GC-MS analyses.
  • Stable to 330340 °C.

Rtx-2330 Columns (fused silica)

highly polar phase; biscyanopropyl cyanopropylphenyl polysiloxane

More Details
  • General-purpose columns for cis/trans FAMEs, dioxin isomers.
  • Temperature range: 0 °C to 275 °C.
  • Equivalent to USP G8 and G48 phase.

Rtx-Wax Columns (fused silica)

polar phase; Crossbond polyethylene glycol

More Details
  • Best polyethylene glycol (PEG) phase for alkenols, glycols, and aldehydes.
  • Temperature range: 20 °C to 250 °C.
  • Equivalent to USP G14, G15, G16, G20, G39 phases.

Rtx-225 Columns (fused silica)

polar phase; Crossbond cyanopropylmethyl phenylmethyl polysiloxane

More Details
  • General-purpose columns for FAMEs, carbohydrates, sterols, flavor compounds.
  • Equivalent to USP G7, G19 phases.

Rtx-65 Columns (fused silica)

mid- to high-polarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General-purpose columns for phenols, fatty acids, triglycerides.
  • Temperature range: 50 °C to 300 °C.

Rtx-200 Columns (fused silica)

midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane

More Details
  • General-purpose columns for solvents, Freon fluorocarbons, alcohols, ketones, silanes, glycols, and drugs of abuse. Excellent confirmation column with an Rtx-5 column for phenols, nitrosamines, organochlorine pesticides, chlorinated hydrocarbons, and chlorophenoxy herbicides.
  • Equivalent to USP G6 phase.

Rtx-50 Columns (fused silica)

midpolarity phase; Crossbond phenyl methyl polysiloxane

More Details
  • General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, sterols.
  • Equivalent to USP G3 phase.

Rtx-35 Columns (fused silica)

midpolarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General-purpose columns for organochlorine pesticides, PCB congeners (e.g., Aroclor mixes), herbicides, pharmaceuticals, sterols, rosin acids, phthalate esters.
  • Temperature range: 40 °C to 320 °C.
  • Equivalent to USP G42 phase.

Rtx-1701 Columns (fused silica)

midpolarity Crossbond phase

More Details
  • General-purpose columns for alcohols, oxygenates, PCB congeners (e.g., Aroclor mixes), pesticides, and fragrance compounds.
  • Equivalent to USP G46 phase.

Rtx-1301 (G43) Columns (fused silica)

low- to midpolarity phase

More Details
  • General-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds.
  • Equivalent to USP G43 phase.

Rtx-20 Columns (fused silica)

low- to midpolarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General-purpose columns for volatile compounds, flavor compounds, alcoholic beverages.
  • Temperature range: -20 °C to 320 °C.
  • Equivalent to USP G28, G32 phases.

Rtx-5 Amine Columns (fused silica)

low-polarity phase; Crossbond 5% diphenyl/95% dimethyl polysiloxane

More Details
  • Application-specific columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.
  • Stable to 315 °C.

Intermediate-Polarity Deactivated Guard/Retention Gap Columns/Transfer Lines (fused silica)

More Details
  • Tested with a comprehensive test mix to ensure high inertness.
  • Useful for a wide range of applications.
  • Use with most common solvents.
  • Maximum temperature: 325 °C.

Rt-γDEXsa Columns (fused silica)

2,3-di-acetoxy-6-O-tert-butyl dimethylsilyl gamma cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane

More Details
Uses: Larger organic molecules. Also useful for flavor compounds in fruit juices.

Rt-βDEXcst Columns (fused silica)

Proprietary cyclodextrin material added into 14% cyanopropylphenyl/86% dimethyl polysiloxane

More Details
Uses: Proprietary stationary phase, developed specifically for the fragrance industry. Also used for pharmaceutical applications.

Rt-βDEXsa Columns (fused silica)

2,3-di-acetoxy-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane

More Details
Uses: Unique selectivity for esters, lactones, and other fruit flavor components.

Rt-βDEXsp Columns (fused silica)

2,3-di-O-propyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane

More Details
Uses: Often useful in dual-column configurations, with the Rt-βDEXsm column, for complex enantiomeric separations.

Rtx-Volatiles Columns (fused silica)

proprietary Crossbond diphenyl/dimethyl polysiloxane phase

More Details
  • Application-specific columns for volatile organic pollutants.
  • Stable to 280 °C.

Rtx-2887 Column (fused silica)

nonpolar phase; Crossbond 100% dimethyl polysiloxanefor simulated distillation

More Details
  • Application-specific column for simulated distillation.
  • Stable to 360 °C.

Rtx-200MSLow-Bleed GC-MS Columns (fused silica)

midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane

More Details
  • General purpose columns for solvents, Freon fluorocarbons, alcohols, ketones, silanes, glycols. Excellent confirmation column with an Rtx-5 column for phenols, nitrosamines, organochlorine pesticides, chlorinated hydrocarbons, and chlorophenoxy herbicides.
  • Equivalent to USP G6 phase.

Rtx-5MSLow-Bleed GC-MS Columns (fused silica)

low-polarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles.
  • Column specifically tested for low-bleed performance.
  • Temperature range: -60 °C to 350 °C.
  • Equivalent to USP G27 and G36 phases.

Rtx-BAC2 Columns (fused silica)

proprietary Crossbond phase

More Details
  • Application-specific columns for blood alcohol analysisachieve baseline resolution in less than 3 minutes. Also excellent for abused inhalant anesthetics, γ-hydroxybutyrate (GHB)/γ-butyrolactone (GBL), glycols, and common industrial solvents.
  • Rtx-BAC2 confirmation column provides four elution order changes under the same conditions.
  • Stable to 260 °C.

Rtx-BAC1 Columns (fused silica)

proprietary Crossbond phase

More Details
  • Application-specific columns for blood alcohol analysisachieve baseline resolution in less than 3 minutes. Also excellent for abused inhalant anesthetics, γ-hydroxybutyrate (GHB)/γ-butyrolactone (GBL), glycols, and common industrial solvents.
  • Rtx-BAC2 confirmation column provides four elution order changes under the same conditions.
  • Stable to 260 °C.

Siltek-Deactivated Guard/Retention Gap Columns/Transfer Lines (fused silica)

More Details
  • Tested with a comprehensive test mix, to ensure high inertness.
  • Revolutionary deactivation process for superior inertness.
  • Analyze active samples accurately; ideal for chlorinated pesticide analysis (reduces endrin breakdown to less than 1%).
  • Maximum temperature: 380 °C.

Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines (fused silica)

More Details
  • Extend analytical column lifetime by preventing degradation from harsh “steam-cleaning” water injections.
  • Tested with a comprehensive test mix, to ensure high inertness.
  • Maximum temperature: 325 °C.

Base-Deactivated Guard/Retention Gap Columns (fused silica)

More Details
  • Tested with a basic amine test mix.
  • Excellent inertness for basic compounds.
  • Recommended for use with Rtx-5 Amine, Rtx-35 Amine, Rtx-Volatile Amine, and Stabilwax-DB capillary columns.
  • Batch test chromatogram included.
  • Maximum temperature: 315 °C.

Polar-Deactivated Guard/Retention Gap Columns (fused silica)

polar polyethylene glycol deactivation

More Details
  • Tested with a comprehensive test mix to ensure high inertness.
  • Polyethylene glycol deactivation layer provides optimum wettability for polar compounds.
  • Minimize peak splitting when using polar solvents such as methanol or water.
  • Compatible with Stabilwax, Rtx-225, and Rt-2330 capillary columns.
  • Maximum temperature: 280 °C.

Rt-βDEXse Columns (fused silica)

2,3-di-O-ethyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane

More Details
Uses: Similar in performance to Rt-βDEXsm but provides better resolution for limonene, linalool, linalyl acetate, ethyl-2-methylbutyrate, 2,3-butane diol, and styrene oxides.

Rt-βDEXsm Columns (fused silica)

2,3-di-O-methyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane

More Details
Uses: Excellent column for most chiral compounds in essential oils.

Rt-βDEXm Columns (fused silica)

permethylated beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane

More Details
Uses: General-purpose chiral phase with many published applications.

Deactivated Fused Silica Tubing (Nonpolar)

More Details
  • Useful as guard columns, transfer lines, or long retention gaps
  • Inertness-tested with the Grob test mix includes test chromatogram.
  • 5-meter banded sections mounted in a Restek cage.
  • Maximum temperature: 325 °C.

Fused Silica Tubing (Undeactivated, Untreated)

More Details
  • Strength-tested.
  • Inexpensive.
  • Coiled in 7-inch diameters, banded in 5-meter sections, and mounted in a Restek cage.

Stx-CLPesticides Column Kit

proprietary Crossbond phases

More Details
  • Application-specific columns for organochlorine pesticides and herbicides.
  • Baseline separations in less than 10 minutes.
  • Siltek surface deactivation enhances responses for endrin, DDT, methoxychlor.
  • Stable to 330 °C.

    Note: Columns are not preconnected in this kit.

Stx-CLPesticides Column Kit, 0.25mm ID

proprietary Crossbond phases

More Details
  • Application-specific columns for organochlorine pesticides and herbicides.
  • Baseline separations in less than 10 minutes.
  • Siltek surface deactivation enhances responses for endrin, DDT, methoxychlor.
  • Stable to 330 °C.

    Note: Columns are not preconnected in this kit.

Stx-CLPesticides2 Columns (fused silica with Siltek deactivation)

proprietary Crossbond phase

More Details
  • Application-specific columns for organochlorine pesticides and herbicides.
  • Baseline separations in less than 10 minutes.
  • Siltek surface deactivation enhances responses for endrin, DDT, methoxychlor.
  • Stable to 330 °C.

Stx-CLPesticides Columns (fused silica with Siltek deactivation)

proprietary Crossbond phase

More Details
  • Application-specific columns for organochlorine pesticides and herbicides.
  • Baseline separations in less than 10 minutes.
  • Siltek surface deactivation enhances responses for endrin, DDT, methoxychlor.
  • Stable to 330 °C.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us