Fused Silica Capillary

Rxi-5Sil MS Columns (fused silica)

low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane

More Details
  • Engineered to be a low-bleed GC-MS column.
  • Excellent inertness for active compounds.
  • General-purpose columnsideal for GC-MS analysis of semivolatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine pesticides, organophosphorus pesticides, drugs, solvent impurities, and hydrocarbons.
  • Temperature range: -60 °C to 350 °C.

Rxi-1ms Columns (fused silica)

nonpolar phase; Crossbond dimethyl polysiloxane

More Details
  • General-purpose columns for arson accelerants, essential oils, hydrocarbons, pesticides, PCB congeners (e.g., Aroclor mixes), sulfur compounds, amines, solvent impurities, simulated distillation, oxygenates, gasoline range organics (GRO), refinery gases.
  • Tested and guaranteed for ultra-low bleed; improved signal-to-noise ratio for better sensitivity and mass spectral integrity.
  • Temperature range: -60 °C to 330/350 °C.
  • Equivalent to USP G1, G2, and G38 phases.

Stabilwax Columns (fused silica)

polar phase; Crossbond polyethylene glycol

More Details
  • Low-bleed PEG column ensures long column lifetimes.
  • Temperature range: 40 °C to 260 °C.
  • Equivalent to USP G14, G15, G16, G20, and G39 phases.

Rxi-624Sil MS Columns (fused silica)

midpolarity Crossbond phase

More Details
  • Low-bleed, high-thermal stability columnmaximum temperatures up to 300320 °C.
  • Inertexcellent peak shape for a wide range of compounds.
  • SelectiveG43 phase highly selective for volatile organics and residual solvents, great choice for USP<467>.
  • Manufactured for column-to-column reproducibilitywell suited for validated methods.

Rxi-17Sil MS Columns (fused silica)

midpolarity Crossbond phase

More Details
  • Excellent inertness and selectivity for active environmental compounds, such as PAHs.
  • Low bleed for use with sensitive detectors, such as MS.
  • 340/360 °C upper temperature limits.
  • Equivalent to USP phase G3.

Stabilwax-DA Columns (fused silica)

polar phase; Crossbond acid-deactivated Carbowax polyethylene glycolfor acidic compounds

More Details
  • Application-specific columns for free (underivatized) acids, some inorganic acids.
  • Resistant to oxidative damage.
  • Equivalent to USP G25, G35 phases.
  • Ideal for analyzing distilled liquor and other alcoholic beverages.

Stabilwax-DB Columns (fused silica)

polar phase; Crossbond base-deactivated Carbowax polyethylene glycolfor amines and basic compounds

More Details
  • Application-specific columns for underivatized amines and other basic compounds, including alkylamines, diamines, triamines, nitrogen-containing heterocyclics. No need for column priming.
  • Temperature range: 40 °C to 220 °C.

Rxi-17 Columns (fused silica)

midpolarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols.
  • Temperature range: 40 °C to 320 °C.

Stabilwax-MS Columns (fused silica)

More Details
  • High-polarity, stable polyethylene glycol (PEG) stationary phase.
  • Low bleed and rugged enough to withstand repeated temperature cycles without retention time shifting.
  • Ideal for food, flavor, fragrance, and industrial chemical and solvent analysis.
  • Temperature range: 40 °C to 250/260 °C.
  • Equivalent to USP G14, G15, G16, G20, and G39 phases.

Rxi-1301Sil MS Columns (fused silica)

midpolarity Crossbond phase

More Details
  • Highest thermal stability in the industry ensures dependable, accurate MS results and increased uptime.
  • Stabilized cyano phase selectivity improves the performance of existing methods. Ideal for solvents, glycols, and other polar compounds.
  • Rigorous QC testing ensures inertness and accurate, reliable data for multiple compound classes.
  • Maximum temperature: 320 °C.

FAMEWAX Columns (USP G16) (fused silica)

polar phase; Crossbond polyethylene glycol

More Details
  • Application-specific columns for FAMEs, specially tested with a FAME mixture.
  • Temperature range: 20 °C to 250 °C.

Rtx-1 Columns (fused silica)

nonpolar phase; Crossbond dimethyl polysiloxane

More Details
  • General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates.
  • Long lifetime and very low bleed at high operating temperatures.
  • Equivalent to USP G1, G2, G38 phases.

Rtx-5 (G27) Columns (fused silica)

low-polarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General-purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles.
  • Equivalent to USP G27 and G36 phases.

Rt-CW20M F&F Columns (fused silica)

polar phase; Carbowax polyethylene glycolnot bonded

More Details
  • Application-specific columns for flavor and fragrance compounds, specially tested.
  • True nonbonded Carbowax 20M polarity.
  • Temperature range: 60 °C to 250 °C.

Rtx-G27 Column (fused silica with 5-meter Integra-Guard guard column)

Crossbond diphenyl dimethyl polysiloxane

More Details
  • Application-specific columns for residual solvents in pharmaceutical products.
  • Analytical column with Integra-Guard guard column eliminates connecting problems and leaks.
  • Rtx-G27 stable to 290 °C.

Rtx-G43 Column (fused silica with 5-meter Integra-Guard guard column)

Crossbond cyanopropylmethyl phenylmethyl polysiloxane

More Details
  • Application-specific columns for residual solvents in pharmaceutical products. Meet all requirements of USP <467>.
  • Analytical column with Integra-Guard guard column eliminates connecting problems and leaks.
  • Rtx-G43 stable to 240 °C.

Rtx-624 Columns (fused silica)

low- to midpolarity phase

More Details
  • Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants.
  • Temperature range: -20 °C to 240 °C.
  • Equivalent to USP G43 phase.

Rtx-35 Amine Columns (fused silica)

midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane

More Details
  • Application-specific columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.

Rtx-5 Amine Columns (fused silica)

low-polarity phase; Crossbond 5% diphenyl/95% dimethyl polysiloxane

More Details
  • Application-specific columns for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.
  • Stable to 315 °C.

Rtx-20 Columns (fused silica)

low- to midpolarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General-purpose columns for volatile compounds, flavor compounds, alcoholic beverages.
  • Temperature range: -20 °C to 320 °C.
  • Equivalent to USP G28, G32 phases.

Rtx-1301 (G43) Columns (fused silica)

low- to midpolarity phase

More Details
  • General-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds.
  • Equivalent to USP G43 phase.

Rtx-1701 Columns (fused silica)

midpolarity Crossbond phase

More Details
  • General-purpose columns for alcohols, oxygenates, PCB congeners (e.g., Aroclor mixes), pesticides, and fragrance compounds.
  • Equivalent to USP G46 phase.

Rtx-35 Columns (fused silica)

midpolarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General-purpose columns for organochlorine pesticides, PCB congeners (e.g., Aroclor mixes), herbicides, pharmaceuticals, sterols, rosin acids, phthalate esters.
  • Temperature range: 40 °C to 320 °C.
  • Equivalent to USP G42 phase.

Rtx-200 Columns (fused silica)

midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane

More Details
  • General-purpose columns for solvents, Freon fluorocarbons, alcohols, ketones, silanes, glycols, and drugs of abuse. Excellent confirmation column with an Rtx-5 column for phenols, nitrosamines, organochlorine pesticides, chlorinated hydrocarbons, and chlorophenoxy herbicides.
  • Equivalent to USP G6 phase.

Rtx-225 Columns (fused silica)

polar phase; Crossbond cyanopropylmethyl phenylmethyl polysiloxane

More Details
  • General-purpose columns for FAMEs, carbohydrates, sterols, flavor compounds.
  • Equivalent to USP G7, G19 phases.

Rtx-Wax Columns (fused silica)

polar phase; Crossbond polyethylene glycol

More Details
  • Best polyethylene glycol (PEG) phase for alkenols, glycols, and aldehydes.
  • Temperature range: 20 °C to 250 °C.
  • Equivalent to USP G14, G15, G16, G20, G39 phases.

Base-Deactivated Guard/Retention Gap Columns (fused silica)

More Details
  • Tested with a basic amine test mix.
  • Excellent inertness for basic compounds.
  • Recommended for use with Rtx-5 Amine, Rtx-35 Amine, Rtx-Volatile Amine, and Stabilwax-DB capillary columns.
  • Batch test chromatogram included.
  • Maximum temperature: 315 °C.

Rtx-5MSLow-Bleed GC-MS Columns (fused silica)

low-polarity phase; Crossbond diphenyl dimethyl polysiloxane

More Details
  • General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles.
  • Column specifically tested for low-bleed performance.
  • Temperature range: -60 °C to 350 °C.
  • Equivalent to USP G27 and G36 phases.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us