share:

HPLC & UHPLC Analytical Columns

You've Selected:

Brand:
Pinnacle DB
Clear All Selections
Show Filters

Pinnacle DB Biphenyl Columns (USP L11)

More Details
Stationary Phase Category: phenyl (L11)
Ligand Type: unique Biphenyl
Particle: 1.9 µm, 3 µm, or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 8%
End-Cap: yes
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Pinnacle DB PFP Propyl Columns (USP L43)

More Details
Stationary Phase Category: fluorophenyl propyl (L43)
Ligand Type: pentafluorophenyl propyl
Particle: 1.9 µm, 3 µm, or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 6%
End-Cap: yes
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Pinnacle DB C8 Columns (USP L7)

More Details
Stationary Phase Category: C8, octylsilane (L7)
Ligand Type: monomeric C8
Particle: 3 µm or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 6%
End-Cap: yes
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Pinnacle DB Cyano Columns (USP L10)

More Details
Stationary Phase Category: cyano (L10)
Ligand Type: cyanopropylsilane
Particle: 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 4%
End-Cap: yes
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Pinnacle DB IBD UHPLC Columns (USP L68)

More Details
Stationary Phase Category: polar-embedded alkyl (L68)
Ligand Type: proprietary polar functional embedded alkyl
Particle: 1.9 µm, spherical
Pore Size: 140 Å
Carbon Load: proprietary
End-Cap: no
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Pinnacle DB PAH UHPLC Columns

More Details
Particle: 1.9 µm, spherical
Pore Size: 140 Å
Carbon Load: proprietary
End-Cap: no
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Pinnacle DB Silica Columns (USP L3)

More Details
Stationary Phase Category: bare silica (L3)
Ligand Type: none
Particle: 1.9 µm, 3 µm, or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: n/a
End-Cap: n/a
Surface Area: 150 m2/g
pH Range: 2.5 to 8.0
Maximum Temperature: 80 °C

Pinnacle DB C18 Columns (USP L1)

More Details
Stationary Phase Category: C18, octadecylsilane (L1)
Ligand Type: monomeric C18
Particle: 1.9 µm, 3 µm, or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 11%
End-Cap: yes
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Pinnacle DB Aqueous C18 Columns (USP L1)

More Details
Stationary Phase Category: modified C18 (L1)
Ligand Type: proprietary polar modified and functionally bonded C18
Particle: 1.9 µm, 3 µm, or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 6%
End-Cap: no
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us