HPLC & UHPLC Analytical Columns

Raptor ARC-18 LC Columns (USP L1)
More Details
- Ideal for high-throughput LC-MS/MS applications with minimal sample preparation.
- Well-balanced retention profile for better detection and integration of large, multiclass analyte lists.
- Sterically protected to endure low-pH mobile phases without sacrificing retention or peak quality.
- Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.

Raptor Biphenyl LC Columns (USP L11)
More Details
- Ideal for bioanalytical testing applications like drug and metabolite analyses.
- Heightened selectivity and retention for compounds that are hard to resolve or elute early on C18 and other phenyl chemistries.
- Limits ionization suppression and allows simple, MS-friendly mobile phases.
- Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.

Raptor FluoroPhenyl LC Columns (USP L43)
More Details
- Capable of both reversed-phase and HILIC separations.
- Ideal for increasing sensitivity and selectivity in LC-MS analyses.
- Offers increased retention for charged bases.
- Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.
- Switch to a Raptor FluoroPhenyl LC column when you need more retention and selectivity for basic and hydrophilic compounds than you can achieve on a C18.

Raptor HILIC-Si LC Columns (USP L3)
More Details
- HILIC silica column designed for increased retention of polar compounds without ion-pairing reagents.
- 2.7 µm Raptor core-shell particles provide the speed of SPP, with greater efficiency and capacity than 5 µm particles.
- Ideal for increasing sensitivity and selectivity in LC-MS analyses.
- Fully compatible with both HPLC and UHPLC when using low back-pressure HILIC mobile phases.
- Switch to a Raptor HILIC-Si LC column when you need more retention and resolution of hydrophilic, polar analytes.

Force FluoroPhenyl LC Columns (USP L43)
More Details
- Capable of both reversed-phase and HILIC separations.
- Ideal for increasing sensitivity and selectivity in LC-MS analyses.
- Offers increased retention for charged bases.

Force C18 LC Columns (USP L1)
More Details
- A traditional end-capped C18 ideal for general-purpose use in reversed-phase chromatography.
- Wide pH range (2–8) provides excellent data quality for many applications, matrices, and compounds.
- Offers high hydrophobic retention.

Force Biphenyl LC Columns (USP L11)
More Details
- Ideal for bioanalytical testing applications like drug and metabolite analyses.
- Heightened selectivity and retention for compounds that are hard to resolve or elute early on C18 and other phenyl chemistries.
- Limits ionization suppression and allows simple, MS-friendly mobile phases.
- Restek’s most popular LC stationary phase.

Ultra Biphenyl Columns (USP L11)
More Details
Stationary Phase Category: phenyl (L11)
Ligand Type: unique Biphenyl
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 15%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C
Ligand Type: unique Biphenyl
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 15%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Allure Silica Columns (USP L3)
More Details
Particle: 5 µm, spherical
Pore Size: 60 Å
Carbon Load: n/a
End-cap: n/a
Surface Area: 450 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C
Highly retentive phase for normal phase separations. Very high surface area, Type B silica packing.
Pore Size: 60 Å
Carbon Load: n/a
End-cap: n/a
Surface Area: 450 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C
Highly retentive phase for normal phase separations. Very high surface area, Type B silica packing.

Ultra C8 Columns (USP L7)
Excellent for a wide range of analyses
More Details
Stationary Phase Category: C8, octylsilane (L7)
Ligand Type: monomeric C8
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 12%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C
Ligand Type: monomeric C8
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 12%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra IBD Columns (USP L68)
Specialized Columns for Mixed Polar and Nonpolar Compounds
More Details
Stationary Phase Category: polar-embedded alkyl (L68)
Ligand Type: proprietary polar functional embedded alkyl
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 12%
End-Cap: no
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C
Ligand Type: proprietary polar functional embedded alkyl
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 12%
End-Cap: no
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Raptor EtG/EtS LC Column
More Details
- Proven performance for accurate, reliable ethyl glucuronide (EtG) and ethyl sulfate (EtS) analysis.
- Strong retention consistently resolves analytes from matrix interferences.
- Long column lifetime ensures consistent performance injection after injection.
- Fast, 4-minute, dilute-and-shoot LC-MS/MS analysis supports high sample throughput.

Ultra PFP Propyl Columns (USP L43)
More Details
Stationary Phase Category: fluorophenyl propyl (L43)
Ligand Type: pentafluorophenyl propyl
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 11%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C
Ligand Type: pentafluorophenyl propyl
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 11%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C