HPLC & UHPLC Analytical Columns

Raptor C18 LC Columns (USP L1)

More Details
  • A traditional end-capped C18 ideal for general-purpose use in reversed-phase chromatography.
  • Wide pH range (2–8) provides excellent data quality for many applications, matrices, and compounds.
  • Offers the highest hydrophobic retention of any Raptor phase.
  • Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.

Raptor Biphenyl LC Columns (USP L11)

More Details
  • Ideal for bioanalytical testing applications like drug and metabolite analyses.
  • Heightened selectivity and retention for compounds that are hard to resolve or elute early on C18 and other phenyl chemistries.
  • Limits ionization suppression and allows simple, MS-friendly mobile phases.
  • Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.

Raptor FluoroPhenyl LC Columns (USP L43)

More Details
  • Capable of both reversed-phase and HILIC separations.
  • Ideal for increasing sensitivity and selectivity in LC-MS analyses.
  • Offers increased retention for charged bases.
  • Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 µm SPP core-shell silica.
  • Switch to a Raptor FluoroPhenyl LC column when you need more retention and selectivity for basic and hydrophilic compounds than you can achieve on a C18.

Raptor HILIC-Si LC Columns (USP L3)

More Details
  • HILIC silica column designed for increased retention of polar compounds without ion-pairing reagents.
  • 2.7 µm Raptor core-shell particles provide the speed of SPP, with greater efficiency and capacity than 5 µm particles.
  • Ideal for increasing sensitivity and selectivity in LC-MS analyses.
  • Fully compatible with both HPLC and UHPLC when using low back-pressure HILIC mobile phases.
  • Switch to a Raptor HILIC-Si LC column when you need more retention and resolution of hydrophilic, polar analytes.

Raptor Polar X LC Columns

More Details
  • Reliably analyze a wide variety of polar analytes (acidic, basic, and neutral) without time-consuming derivatization or complex ion pairing.
  • Switch between HILIC and ion-exchange retention modes with simple mobile phase changes and short equilibration times.
  • 2.7 μm Raptor core-shell particles provide UHPLC-like speed and efficiency on all makes and models of LC systems.
  • Ideal for increasing sensitivity and selectivity in LC-MS analyses.

Storage Conditions: When not in use, Raptor Polar X columns must be kept in 100% acetonitrile. If using a buffered mobile phase, first flush thoroughly with 50:50 water:acetonitrile, then fill with acetonitrile for storage.


Force FluoroPhenyl LC Columns (USP L43)

More Details
  • Capable of both reversed-phase and HILIC separations.
  • Ideal for increasing sensitivity and selectivity in LC-MS analyses.
  • Offers increased retention for charged bases.

Force C18 LC Columns (USP L1)

More Details
  • A traditional end-capped C18 ideal for general-purpose use in reversed-phase chromatography.
  • Wide pH range (2–8) provides excellent data quality for many applications, matrices, and compounds.
  • Offers high hydrophobic retention.

Force Biphenyl LC Columns (USP L11)

More Details
  • Ideal for bioanalytical testing applications like drug and metabolite analyses.
  • Heightened selectivity and retention for compounds that are hard to resolve or elute early on C18 and other phenyl chemistries.
  • Limits ionization suppression and allows simple, MS-friendly mobile phases.
  • Restek’s most popular LC stationary phase.

Ultra Biphenyl Columns (USP L11)

More Details
Stationary Phase Category: phenyl (L11)
Ligand Type: unique Biphenyl
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 15%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Roc C8 HPLC Columns (USP L7)

More Details
  • Conventional HPLC column built to be the cornerstone for your lab; pressure rated for any 400 bar HPLC system.
  • Solid and reliable—delivers the peak shape, reproducibility, ruggedness, and performance you demand.
  • Exceptional value for routine analyses and large-volume workflows—high-purity, fully porous silica backed by quality manufacturing features a variety of phases to fit most HPLC methods.
  • Ideal for a wide range of applications from food to pharma;
    5 phases cover 98% of USP methods.

Roc C18 HPLC Columns (USP L1)

More Details
  • Conventional HPLC column built to be the cornerstone for your lab; pressure rated for any 400 bar HPLC system.
  • Solid and reliable—delivers the peak shape, reproducibility, ruggedness, and performance you demand.
  • Exceptional value for routine analyses and large-volume workflows—high-purity, fully porous silica backed by quality manufacturing features a variety of phases to fit most HPLC methods.
  • Ideal for a wide range of applications from food to pharma;
    5 phases cover 98% of USP methods.

Roc Phenyl-Hexyl HPLC Columns (USP L11)

More Details
  • Conventional HPLC column built to be the cornerstone for your lab; pressure rated for any 400 bar HPLC system.
  • Solid and reliable—delivers the peak shape, reproducibility, ruggedness, and performance you demand.
  • Exceptional value for routine analyses and large-volume workflows—high-purity, fully porous silica backed by quality manufacturing features a variety of phases to fit most HPLC methods.
  • Ideal for a wide range of applications from food to pharma;
    5 phases cover 98% of USP methods.

Roc Cyano HPLC Columns (USP L10)

More Details
  • Conventional HPLC column built to be the cornerstone for your lab; pressure rated for any 400 bar HPLC system.
  • Solid and reliable—delivers the peak shape, reproducibility, ruggedness, and performance you demand.
  • Exceptional value for routine analyses and large-volume workflows—high-purity, fully porous silica backed by quality manufacturing features a variety of phases to fit most HPLC methods.
  • Ideal for a wide range of applications from food to pharma;
    5 phases cover 98% of USP methods.

Roc Silica HPLC Columns (USP L3)

More Details
  • Conventional HPLC column built to be the cornerstone for your lab; pressure rated for any 400 bar HPLC system.
  • Solid and reliable—delivers the peak shape, reproducibility, ruggedness, and performance you demand.
  • Exceptional value for routine analyses and large-volume workflows—high-purity, fully porous silica backed by quality manufacturing features a variety of phases to fit most HPLC methods.
  • Ideal for a wide range of applications from food to pharma;
    5 phases cover 98% of USP methods.

Pinnacle DB Cyano Columns (USP L10)

More Details
Stationary Phase Category: cyano (L10)
Ligand Type: cyanopropylsilane
Particle: 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 4%
End-Cap: yes
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Viva Biphenyl Columns (USP L11)

More Details
Stationary Phase Category: phenyl (L11)
Ligand Type: Biphenyl
Particle: 5 µm, spherical
Pore Size: 300 Å
Carbon Load: 7%
End-Cap: yes
Surface Area: 100 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Pinnacle DB IBD UHPLC Columns (USP L68)

More Details
Stationary Phase Category: polar-embedded alkyl (L68)
Ligand Type: proprietary polar functional embedded alkyl
Particle: 1.9 µm, spherical
Pore Size: 140 Å
Carbon Load: proprietary
End-Cap: no
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Viva C18 Columns (USP L1)

More Details
Stationary Phase Category: C18, octadecylsilane (L1)
Ligand Type: monomeric C18
Particle: 3 µm or 5 µm, spherical
Pore Size: 300 Å
Carbon Load: 9%
End-Cap: yes
Surface Area: 100 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Viva C4 Columns (USP L26)

More Details
Stationary Phase Category: C4, butylsilane (L26)
Ligand Type: monomeric C4
Particle: 5 µm, spherical
Pore Size: 300 Å
Carbon Load: 3.5%
End-Cap: yes
Surface Area: 100 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Pinnacle DB Silica Columns (USP L3)

More Details
Stationary Phase Category: bare silica (L3)
Ligand Type: none
Particle: 1.9 µm, 3 µm, or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: n/a
End-Cap: n/a
Surface Area: 150 m2/g
pH Range: 2.5 to 8.0
Maximum Temperature: 80 °C

Viva C8 Columns (USP L7)

More Details
Stationary Phase Category: C8, octylsilane (L7)
Ligand Type: monomeric C8
Particle: 5 µm, spherical
Pore Size: 300 Å
Carbon Load: 5%
End-Cap: yes
Surface Area: 100 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Viva PFP Propyl Columns (USP L43)

More Details
Stationary Phase Category: fluorophenyl propyl (L43)
Ligand Type: pentafluorophenyl propyl
Particle: 5 µm, spherical
Pore Size: 300 Å
Carbon Load: 5%
End-Cap: yes
Surface Area: 100 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Viva Silica Columns (USP L3)

More Details
Stationary Phase Category: bare silica (L3)
Ligand Type: none
Particle: 5 µm, spherical
Pore Size: 300 Å
Carbon Load: n/a
End-Cap: n/a
Surface Area: 100 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra Silica Columns (USP L3)

More Details
Stationary Phase Category: bare silica (L3)
Ligand Type: none
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: n/a
End-Cap: n/a
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra PFP Propyl Columns (USP L43)

More Details
Stationary Phase Category: fluorophenyl propyl (L43)
Ligand Type: pentafluorophenyl propyl
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 11%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra Aromax Columns (USP L11)

More Details
Stationary Phase Category: phenyl (L11)
Ligand Type: proprietary phenyl ligand
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 17%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Allure Silica Columns (USP L3)

More Details

Particle: 5 µm, spherical
Pore Size: 60 Å
Carbon Load: n/a
End-cap: n/a
Surface Area: 450 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Highly retentive phase for normal phase separations. Very high surface area, Type B silica packing.

Performing MOSH/MOAH analysis? Use cat.# 9160572 below.


Ultra Amino Columns (USP L8)

More Details
Stationary Phase Category: amino (L8)
Ligand Type: aminopropylsilane
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 2%
End-Cap: no
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra Aqueous C18 Columns (USP L1)

More Details
Stationary Phase Category: modified C18 (L1)
Ligand Type: proprietary polar modified and functionally bonded C18
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 15%
End-Cap: no
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Allure AK Columns

More Details
Particle: 5 µm, spherical
Pore Size: 60 Å
Carbon Load: proprietary
End-Cap: yes
Surface Area: 450 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra C1 Columns (USP L13)

More Details
Stationary Phase Category: trimethylsilane (L13)
Ligand Type: monomeric C1
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 5%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra C18 Columns (USP L1)

Excellent for a wide range of analyses

More Details
Stationary Phase Category: C18, octadecylsilane (L1)
Ligand Type: monomeric C18
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 20%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra C4 Columns (USP L26)

More Details
Stationary Phase Category: C4, butylsilane (L26)
Ligand Type: monomeric C4
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 9%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra C8 Columns (USP L7)

Excellent for a wide range of analyses

More Details
Stationary Phase Category: C8, octylsilane (L7)
Ligand Type: monomeric C8
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 12%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra Cyano Columns (USP L10)

More Details
Stationary Phase Category: cyano (L10)
Ligand Type: cyanopropylsilane
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 8%
End-Cap: yes
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Ultra IBD Columns (USP L68)

Specialized Columns for Mixed Polar and Nonpolar Compounds

More Details
Stationary Phase Category: polar-embedded alkyl (L68)
Ligand Type: proprietary polar functional embedded alkyl
Particle: 3 µm or 5 µm, spherical
Pore Size: 100 Å
Carbon Load: 12%
End-Cap: no
Surface Area: 300 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Allure Organic Acids Columns

More Details
Particle: 5 µm, spherical
Pore Size: 60 Å
Carbon Load: proprietary
End-Cap: no
Surface Area: 450 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Pinnacle DB Aqueous C18 Columns (USP L1)

More Details
Stationary Phase Category: modified C18 (L1)
Ligand Type: proprietary polar modified and functionally bonded C18
Particle: 1.9 µm, 3 µm, or 5 µm, spherical
Pore Size: 140 Å
Carbon Load: 6%
End-Cap: no
Surface Area: 150 m2/g
pH Range: 2.5 to 8
Maximum Temperature: 80 °C

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us