Reference Standards: Other

Looking for a Specific Compound?
Enter a compound name, synonym, or CAS # below.

Silylation Derivatization Reagents

More Details
  • Replace active hydrogen, reducing polarity and making the compounds more volatile.
  • Increase stability of derivatives.

Alkylation Derivatization Reagents

More Details
  • Add alkyl groups to functional hydrogens (H).
  • Decrease polarity on compounds containing acidic hydrogens, i.e., phenols, carboxylic acids.
  • Form an ester.

Acylation Derivatization Reagents

More Details
  • Most commonly used for electron capture detection.
  • React with alcohols, amines, and phenols.
  • Frequently used for drugs of abuse confirmation.

Weathered Diesel Fuel #2 Kit

More Details
Contains 1 mL each of these 5000 µg/mL in methylene chloride mixtures.
31233: Diesel Fuel #2 Standard
31234: Diesel Fuel #2 Standard: 25% Weathered
31235: Diesel Fuel #2 Standard: 50% Weathered
31236: Diesel Fuel #2 Standard: 75% Weathered

Weathered Kerosene Kit

More Details
Contains 1 mL each of these mixtures.
31229: Kerosene Standard
31230: Kerosene Standard: 25% Weathered
31231: Kerosene Standard: 50% Weathered
31232: Kerosene Standard: 75% Weathered

Weathered Gasoline Kit #2

More Details
Contains 1 mL each of these mixtures.
30096: Unleaded Gasoline Standard
30097: Unleaded Gasoline Standard: 25% Weathered
30098: Unleaded Gasoline Standard: 50% Weathered
30099: Unleaded Gasoline Standard: 75% Weathered
30436: Unleaded Gasoline Standard: 99% Weathered

Mineral Spirits

More Details
There are four general types of mineral spirits, classified according to boiling point range (BPR):
  • Type I (Stoddard solvent), BPR 149–182 °C
  • Type II (high flash point), BPR 177–196 °C
  • Type III (odorless), BPR 149–196 °C
  • Type IV (low dry point), BPR 149–174 °C

    This standard is manufactured using the Type 1 mineral spirit.

    Note: Cat.#s 31260 and 31261 are produced with CAS# 64475-85-0, a Type 1 Mineral Spirit containing the proper ratio of n-alkanes (higher proportion) and isoparaffins/cycloalkanes (lower proportion). Lots produced prior to March 2017 contained CAS# 8030-30-6, a C10-C13 isoparaffins odorless Mineral Spirit with >98% isoparaffins (branched alkanes/aromatics) and minimal n-alkanes.

Diesel Fuel #2 (ASTM Class 5 Accelerant)

More Details
Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

Kerosene (ASTM Class 4 Accelerant)

More Details
Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

Unleaded Gasoline (ASTM Class 2 Accelerant)

More Details
Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

Stoddard Solvent Standard

More Details
We offer this certified reference material for those who need to calibrate Stoddard solvent separately. This standard is dissolved in methanol for analysis by either direct injection or purge and trap.