Reference Standards: Compounds & Classes

You've Selected:

Compounds & Classes:
Hydrocarbons
Clear All Selections
Show Filters
Looking for a Specific Compound?
Enter a compound name, synonym, or CAS # below.

Mineral Spirits

More Details

There are four general types of mineral spirits, classified according to boiling point range (BPR):

  • Type I (Stoddard solvent), BPR 149–182 °C
  • Type II (high flash point), BPR 177–196 °C
  • Type III (odorless), BPR 149–196 °C
  • Type IV (low dry point), BPR 149–174 °C

This standard is manufactured using the Type 1 mineral spirit.

Note: Cat.#s 31260 and 31261 are produced with CAS# 64475-85-0, a Type 1 Mineral Spirit containing the proper ratio of n-alkanes (higher proportion) and isoparaffins/cycloalkanes (lower proportion). Lots produced prior to March 2017 contained CAS# 8030-30-6, a C10-C13 isoparaffins odorless Mineral Spirit with >98% isoparaffins (branched alkanes/aromatics) and minimal n-alkanes.


418.1 Calibration Mix (3 components)

More Details
Method 418.1 is an infrared spectrophotometric method for determining Total Recoverable Petroleum Hydrocarbons (TRPH). Dilute this mixture 1:200 to make the stock mixture specified in section 6.5.2 of Method 418.1.

Weathered Gasoline Kit #2

More Details
Contains 1 mL each of these mixtures.
30096: Unleaded Gasoline Standard
30097: Unleaded Gasoline Standard: 25% Weathered
30098: Unleaded Gasoline Standard: 50% Weathered
30099: Unleaded Gasoline Standard: 75% Weathered
30436: Unleaded Gasoline Standard: 99% Weathered

EFSA PAH4 Standard (4 components)

More Details
  • European Food Safety Authority (EFSA) PAH4 compounds prepared in toluene solvent.
  • High 1,000 µg/mL concentration—dilute as needed to economically prepare custom mixes.
  • Low volatility—longer shelf life and more accurate results.
  • High miscibility—compatible with QuEChERS solvents.
  • Pair with Rxi-PAH GC column for easy separation of EFSA PAH4 compounds from common interferences in food and environmental samples.

Certified Aromatics in Gasoline (16 components)

More Details
  • Confirm unleaded gasoline TPH, BTEX, and aromatics in a single analysis.
  • Certificate of Analysis includes concentration of TPH, and certified concentrations of BTEX and individual aromatics.
  • Complete data pack available.

Weathered Kerosene Kit

More Details
Contains 1 mL each of these mixtures.
31229: Kerosene Standard
31230: Kerosene Standard: 25% Weathered
31231: Kerosene Standard: 50% Weathered
31232: Kerosene Standard: 75% Weathered

Hydraulic Oil Standard

More Details
  • For total petroleum hydrocarbon pattern recognition of hydraulic oil.
  • High concentration—50,000 µg/mL in methylene chloride.

Weathered Diesel Fuel #2 Kit

More Details
Contains 1 mL each of these 5000 µg/mL in methylene chloride mixtures.
31233: Diesel Fuel #2 Standard
31234: Diesel Fuel #2 Standard: 25% Weathered
31235: Diesel Fuel #2 Standard: 50% Weathered
31236: Diesel Fuel #2 Standard: 75% Weathered

Creosote Oil Standard

More Details

Creosote oil is a coal tar derived distillate.

For total petroleum hydrocarbon pattern recognition of creosote oil.

High concentration—50,000 µg/mL in methylene chloride.


CCME PHC Calibration Mix (3 components)

More Details
  • Meets CCME 2001 Petroleum Hydrocarbons in Soil Method—Tier 1.
  • Primary reference calibration standards for quantification of four fractions.

Unleaded Gasoline Composite Standard

More Details
  • Unleaded gasoline composite standards are comprised of three separate sources each of 87, 89, and 93 octane blended in equal portions.
  • Gasoline standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.
Note: BTEX content of catalog numbers 30081, 30205, and 30206 is not measured. Certified BTEX gasoline standards are available as catalog numbers 30237 and 30485.

Used Motor Oil Composite Standard

More Details
  • Prepared from an equal-volume blend from five gasoline-powered vehicles (belonging to Restek employees). After blending, a precisely weighed amount of the composite is added to a volumetric flask to produce the standard.
  • Motor oil standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Fuel Oil #4 Standard

More Details
Fuel oil #4 is typically used in limited applications in which the fuel cannot be preheated prior to burning. The fuel is a blend of distillate (fuel oil #2) and residual (fuel oil #6).

Diesel Fuel #2 Composite Standard

More Details
  • Diesel Fuel composite standards are comprised of three separate sources blended in equal portions.
  • Diesel Fuel standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Standard Mixture Stock Solution (2 components)

More Details
  • For GC analysis of total petroleum hydrocarbons (TPH) in water.
  • Calibration standard available as diesel #2/motor oil and diesel #2/mineral oil.

Fuel Oil Degradation Mix (4 components)

More Details
Subsurface degradation of fuel oil spills can be estimated by examining the ratios of C17/pristane and C18/phytane.1 To assist in identifying these four compounds from the complex fuel oil analysis, we offer a product that contains these compounds for retention time determination.

Motor Oil Composite Standard

More Details
  • Prepared from an equal-volume blend of 5W30, 10W30, 10W40, and 20W50 motor oils. After blending, a precisely weighed amount of the composite is added to a volumetric flask to produce the standard.
  • Motor oil standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Quality Control Standard Mixture, Revised (2 components)

More Details
  • Updated reference materials for GC analysis of TPH in water.
  • Determination of hydrocarbon oil index—applicable to drinking, surface, waste, and treated water.

TNRCC 1005 Retention Time Markers Mix (4 components)

More Details
  • Easily determine the retention time window for each boiling point range.
  • Prepared in n-pentane according to EPA requirements.

Stoddard Solvent Standard

More Details
We offer this certified reference material for those who need to calibrate Stoddard solvent separately. This standard is dissolved in methanol for analysis by either direct injection or purge and trap.

Fuel Oil #6 Standard

More Details
A high-viscosity residual type of heavy fuel oil requiring preheating to 104–127 °C. This material is also known as residual fuel oil (RFO) or Bunker C.

Quality Control Standard Mixture (2 components)

More Details
  • For GC analysis of total petroleum hydrocarbons (TPH) in water.
  • Environmentally safer than previous methods.
  • Calibration standard available as diesel #2/motor oil and diesel #2/mineral oil.

BTEX Gas Mix (6 components)

More Details

Our high-quality air monitoring gas calibration standards are provided by Spectra/Linde and Airgas (formerly Scott/Air Liquide gas)—meeting lab requirements for two separate sources of calibration standards.

Note: Actual cylinder pressure may vary due to loss from quality testing procedure.


SV Internal Standard Mix (6 components)

More Details
  • High purity for consistent results.
  • Free quality assurance data package available online.
  • Highest concentrations commercially available.

Diesel:Biodiesel (80:20) Blend Standard

More Details
The biodiesel component is methyl soyate.

Kerosene Composite Standard

More Details
  • Kerosene composite standards are comprised of three separate sources blended in equal portions.
  • Kerosene standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Aviation Gas Standard

More Details
100-octane, low-lead fuel used in piston-type aircraft.

Kerosene (ASTM Class 4 Accelerant)

More Details
Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

Unleaded Gasoline (ASTM Class 2 Accelerant)

More Details
Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

B/N Surrogate Mix (4/89 SOW) (3 components)

More Details
  • High purity for consistent results.
  • Free quality assurance data package available online.
  • Highest concentrations commercially available.
  • Convenient 1 mL, 5 mL, and 10 mL package sizes reduce cost per sample extract.

Diesel Fuel #2 (ASTM Class 5 Accelerant)

More Details
Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

Qualitative Retention Time Index Standard (27 components)

More Details
  • Appropriate for a wide range of retention index systems.
  • Certified reference material (CRM) verified to be stable and accurate.
  • Qualitatively analyzed to confirm composition; certificate available for each CRM lot.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us