Reference Standards: Underground Storage Tank Monitoring (UST)

Qualitative Retention Time Index Standard (27 components)

More Details
  • Appropriate for a wide range of retention index systems.
  • Certified reference material (CRM) verified to be stable and accurate.
  • Qualitatively analyzed to confirm composition; certificate available for each CRM lot.

Diesel:Biodiesel (80:20) Blend Standard

More Details
The biodiesel component is methyl soyate.

Mineral Spirits

More Details
There are four general types of mineral spirits, classified according to boiling point range (BPR):
  • Type I (Stoddard solvent), BPR 149–182 °C
  • Type II (high flash point), BPR 177–196 °C
  • Type III (odorless), BPR 149–196 °C
  • Type IV (low dry point), BPR 149–174 °C

    This standard is manufactured using the Type 1 mineral spirit.

    Note: Cat.#s 31260 and 31261 are produced with CAS# 64475-85-0, a Type 1 Mineral Spirit containing the proper ratio of n-alkanes (higher proportion) and isoparaffins/cycloalkanes (lower proportion). Lots produced prior to March 2017 contained CAS# 8030-30-6, a C10-C13 isoparaffins odorless Mineral Spirit with >98% isoparaffins (branched alkanes/aromatics) and minimal n-alkanes.

MA VPH Matrix Spike Mix with Surrogate Rev. 1.1 (July 2004) (16 components)

More Details
  • For current Massachusetts VPH method: surrogate included.
  • Matrix spike mix at 50µg/mL, per updated method.

MA VPH Standard with Surrogate Rev. 1.1 (July 2004) (16 components)

More Details
  • Standard for current Massachusetts VPH method: surrogate included.
  • More analyses per ampulstandard with surrogate is 10,000µg/mL.

CA WIP VOA Standard (11 components)

More Details
For monitoring samples suspected of gasoline contamination, Los Angeles County requires laboratories to calibrate and report these compounds.

Certified Aromatics in Gasoline (16 components)

More Details
  • Confirm unleaded gasoline TPH, BTEX, and aromatics in a single analysis.
  • Certificate of Analysis includes concentration of TPH, and certified concentrations of BTEX and individual aromatics.
  • Complete data pack available.

Stoddard Solvent Standard

More Details
We offer this certified reference material for those who need to calibrate Stoddard solvent separately. This standard is dissolved in methanol for analysis by either direct injection or purge and trap.

Fuel Oil Degradation Mix (4 components)

More Details
Subsurface degradation of fuel oil spills can be estimated by examining the ratios of C17/pristane and C18/phytane.1 To assist in identifying these four compounds from the complex fuel oil analysis, we offer a product that contains these compounds for retention time determination.

Diesel Fuel #2 Standard

More Details
Prepared from a single-source (one-refinery) product.

Kerosene Standard

More Details
Prepared from a single-source (one-refinery) product.

Unleaded Gasoline Standard

More Details
Prepared from a single-source (one-refinery) product.

Hydraulic Oil Standard

More Details
  • For total petroleum hydrocarbon pattern recognition of hydraulic oil.
  • High concentration50,000 µg/mL in methylene chloride.

Creosote Oil Standard

More Details
Creosote oil is a coal tar derived distillate.

  • For total petroleum hydrocarbon pattern recognition of creosote oil.
  • High concentration50,000 µg/mL in methylene chloride.

Aviation Gas Standard

More Details
100-octane, low-lead fuel used in piston-type aircraft.

Fuel Oil #6 Standard

More Details
A high-viscosity residual type of heavy fuel oil requiring preheating to 104–127 °C. This material is also known as residual fuel oil (RFO) or Bunker C.

Fuel Oil #4 Standard

More Details
Fuel oil #4 is typically used in limited applications in which the fuel cannot be preheated prior to burning. The fuel is a blend of distillate (fuel oil #2) and residual (fuel oil #6).

Used Motor Oil Composite Standard

More Details
  • Prepared from an equal-volume blend from five gasoline-powered vehicles (belonging to Restek employees). After blending, a precisely weighed amount of the composite is added to a volumetric flask to produce the standard.
  • Motor oil standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Motor Oil Composite Standard

More Details
  • Prepared from an equal-volume blend of 5W30, 10W30, 10W40, and 20W50 motor oils. After blending, a precisely weighed amount of the composite is added to a volumetric flask to produce the standard.
  • Motor oil standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Kerosene Composite Standard

More Details
  • Kerosene composite standards are comprised of three separate sources blended in equal portions.
  • Kerosene standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Diesel Fuel #2 Composite Standard

More Details
  • Diesel Fuel composite standards are comprised of three separate sources blended in equal portions.
  • Diesel Fuel standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Unleaded Gasoline Composite Standard

More Details
  • Unleaded gasoline composite standards are comprised of three separate sources each of 87, 89, and 93 octane blended in equal portions.
  • Gasoline standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

    NOTE: BTEX content of catalog numbers 30081, 30205, and 30206 is not measured. Certified BTEX gasoline standards are available as catalog numbers 30237 and 30485.

TNRCC 1005 Retention Time Markers Mix (4 components)

More Details
  • Easily determine the retention time window for each boiling point range.
  • Prepared in n-pentane according to EPA requirements.

Massachusetts APH Mix (26 components)

More Details
Our high-quality air monitoring gas calibration standards are provided by Spectra/Linde and Airgas (formerly Scott/Air Liquide gas)meeting lab requirements for two separate sources of calibration standards.

Note: Actual cylinder pressure may vary due to loss from quality testing procedure.

To view compatible regulators, select your standard below and see Restek Recommends.

BTEX Gas Mix (6 components)

More Details
Our high-quality air monitoring gas calibration standards are provided by Spectra/Linde and Airgas (formerly Scott/Air Liquide gas)meeting lab requirements for two separate sources of calibration standards.

Note: Actual cylinder pressure may vary due to loss from quality testing procedure.

To view compatible regulators, select your standard below and see Restek Recommends.