Reference Standards: Test Mixes

Show Filters
Looking for a Specific Compound?
Enter a compound name, synonym, or CAS # below.

SPME Performance Test Mix (2 components)

More Details
  • Essential mix for establishing the performance of SPME fibers and SPME Arrows.
  • Verified composition and stability.

Dimethyldichlorosilane (DMDCS) Deactivating Agent

More Details
  • Easy deactivation of liners and other glass surfaces.
  • Convenient25 mL bottle deactivates 60 inlet liners.
  • Tested to ensure consistent quality and effectiveness.

LC OQ Standards Kit

More Details
This kit contains one ampul of each of the following items (unless otherwise specified):
30012: LC OQ gradient standard, 1 mL
31053: LC OQ wavelength accuracy standard, 5 mL
31068: LC OQ linearity kit, six 1 mL ampuls (contents detailed below)*

*Components of the LC linearity kit (cat.# 31068) are not available for individual sale.

Silylation Derivatization Reagents

More Details
  • Replace active hydrogen, reducing polarity and making the compounds more volatile.
  • Increase stability of derivatives.

Alkylation Derivatization Reagents

More Details
  • Add alkyl groups to functional hydrogens (H).
  • Decrease polarity on compounds containing acidic hydrogens, i.e., phenols, carboxylic acids.
  • Form an ester.

Acylation Derivatization Reagents

More Details
  • Most commonly used for electron capture detection.
  • React with alcohols, amines, and phenols.
  • Frequently used for drugs of abuse confirmation.

LC Performance Test Mix (5 components)

More Details
  • Highly effective for characterizing LC column parameters.
  • Simple, easy, reliable approach to quality control (QC) evaluations or column classification.
  • Monitor column performance over time.

Carbohydrate LC Performance Check Mix (5 components)

More Details
  • For simple sugar analysis by LC with refractive index/light scattering detection.
  • Use with a silica column with amino functionality, as recommended by AOAC International.
  • Use as a calibration standard for AACC Method 80-04.
  • Offered dry for enhanced stability.

LC OQ Linearity Test Mix Kit

More Details
Contains 1 mL each of these mixtures.
31804: Caffeine (caffeine at 5 µg/mL in water)
31803: Caffeine (caffeine at 25 µg/mL in water)
31802: Caffeine (caffeine at 125 µg/mL in water)
31801: Caffeine (caffeine at 250 µg/mL in water)
31800: Caffeine (caffeine at 500 µg/mL in water)

LC Reversed Phase Test Mix #1 (4 components)

More Details
Routine analysis using this mix can assist in determining the need to perform column and/or system maintenance.

LC Normal Phase Test Mix #1 (4 components)

More Details
Routine analysis using this mix can assist in determining the need to perform column and/or system maintenance.

Amine Column Test Mix (GC) (8 components)

More Details
For Stabilwax-DB, Rtx-5 Amine, Rtx-35 Amine, and Rtx-Volatile Amine columns.

Grob Test Mix (Capillary GC) (12 components)

More Details
For use with temperature-programmed conditions.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us