Personal Air Samplers

Aura Personal Air Sampler Kits

More Details
  • New personal air sampling technology designed to comply with NIOSH Method 3900 and OSHA requirements for industrial hygiene applications.
  • Quiet, robust sampler does not require a pump and manages variations in face velocity, temperature, and humidity better than traditional sampling approaches.
  • Easy to operatea simple, quick connection starts and stops flow; does not require flow calibration.
  • Whole air sampling approach affords multiple analyses of over 100 VOCs. Broader utility than analyte-specific sorbent techniques.
  • Wider effective range than sorbent tubes and badges. Sensitive down to pptv levels and not subject to sample breakthrough even at ppmv levels.
  • Green technology does not use electricity or solvents.
  • Fully adjustable for a comfortable, secure fit.

RAVEqc Quick-Connect Air Valves

More Details
  • Simplify your workflow—tool-free design makes it fast and easy for anyone to make consistent, quality connections.
  • Extend air canister and valve lifetime—no wrenches mean no overtightening or cross-threading damage.
  • Standalone or supporting roles—use alone or pair with a bellows/diaphragm valve for the ultimate in sample security and convenience.
  • Check status at a glance—if the parts are connected, the valve is open; if they’re apart, it’s closed.
  • Standard compression or tube end fittings accommodate a wide variety of air canisters and related devices.
  • Leak-free performance—each and every valve is helium leak tested to 1x10-6 mL/sec.
  • Compatible with Entech Micro-QT valves.

    Note: A RAVEqc valve bracket is required for use with Restek 1, 3, 6, and 15 L air sampling canisters when using the compression fitting mounted directly on the 1/4" canister tube stub. This bracket is not needed when using Restek miniature canisters or Entech canisters.

Miniature Air Sampling Canisters (Electropolished Stainless Steel & Siltek Treated)

More Details
  • Ideal for indoor air, personal, emergency response, or soil gas sampling.
  • Available with RAVEqc quick-connect fitting that is compatible with sampling and analysis instruments.

Digital Gauge with Quick-Connect Fitting

More Details
  • Measures vacuum to -30" Hg and pressure to 60 psi with ± 0.25% accuracy.
  • Includes a hard-sided carrying case.
  • Compatible with miniature air sampling canisters and Aura personal air samplers.

Tube End Reducer (Brass, Stainless Steel & Treated)

Swagelok

More Details
Restek is pleased to offer one of the premier lines of fittings available for chromatographers in the market today. We can supply the entire line of Swagelok fittings. Fittings are available in brass and stainless steel. Siltek/Sulfinert treated or Silcosteel-CR treated fittings are also available. If you don't see the exact product you're looking for, please call us for a quote.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us