Column Connectors

Show Filters

Defined PressFit Connectors

More Details
  • Defined fit: ID-specific ends for better sealability.
  • Color-coded for easy identification.
  • Deactivated borosilicate glass.
  • Connect a guard column to an analytical column.
  • Repair a broken column.
  • Connect a column outlet to a transfer line.

SilTite µ-Union Connectors

More Details
  • Reliably create permanent connections between fused silica analytical columns, guard columns, and retention gaps.
  • SilTite FingerTite technology provides easy installation and a permanent leak-tight connection.
  • Deactivated metal and zero-dead-volume design ensure optimal peak shapes.
  • Robust connection is stable through extreme temperature and pressure cycling, making it ideal for use with mass spectrometers.
  • Kits contain two SilTite µ-Union connectors, five double-taper ferrules, and installation tools.

Universal Press-Tight Connectors

More Details
  • Connect a guard column to an analytical column.
  • Repair a broken column.
  • Connect a column outlet to a transfer line.

Universal "Y" Press-Tight Connectors

More Details
  • Split sample flowperform dual-column confirmation analysis with a single injection.
  • Split column flow to two detectors.

Universal Angled "Y" Press-Tight Connectors

More Details
  • Split sample flowperform dual-column confirmation analysis with a single injection.
  • Split column flow to two detectors.
  • Inlet and outlet ends match column curvature to alleviate connection strain.

MXT "Y"-Union Connector Kits for Connecting Metal and/or Fused Silica GC Columns

More Details
  • Low-dead-volume, leak-tight connection.
  • Reusable.
  • Siltek treatment ensures maximum inertness.
  • Ideal for connecting a guard column or transfer line to an analytical column.
  • Use to oven temperatures of 350 °C.
  • Available in union and "Y" configurations.
  • Can also be used for connecting fused silica to metal.

Zero Dead Volume Valco Internal Union

More Details
Ends of tubing seat squarely at bottoms of fitting details. Made of 300-series stainless steel. For use with 1/16" OD tubing. Stainless steel ferrules included.

Vu2 Union Connectors

More Details
  • Connect a guard column to an analytical column.
  • Connect a column to a transfer line.
  • Connect two columns in series.
  • Repair a broken column.
  • Fit both Restek cage designs.

SeCure "Y" Connector Kits

More Details
  • Connect two analytical columns to a transfer line or guard column.
  • Use standard "Y" Press-Tight connectors and 1/16" graphite ferrules.
  • Reliable seal integritywill not unexpectedly disconnect during temperature-programmed analyses.
  • Open design allows visual confirmation of the seal for added confidence in the connection.
  • Fit both Restek cage designs.

MXT Low Dead Volume Connector Kits for Metal Columns

More Details
  • Connect a guard column/transfer line to an MXT stainless steel column.
  • Low thermal mass tracks rapid oven temperature programming.
  • Stainless steel ferrules and nuts.
  • Available in "Y" and union configurations.
  • Siltek treatment ensures ultimate inertness.

    Each kit contains the MXT union, two 1/32-inch ferrules and nuts.

MXT-Union Connector Kits for Connecting Metal and/or Fused Silica GC Columns

More Details
  • Low dead volume, leak-tight connection.
  • Reusable.
  • Siltek treatment ensures maximum inertness.
  • Ideal for connecting a guard column or transfer line to an analytical column.
  • Use to oven temperatures of 350 °C.
  • Available in union and "Y" configurations.
  • Can also be used for connecting fused silica to metal.

Zero-Dead-Volume Valco Internal Cross

More Details
Connect four lines. 300 series stainless steel; stainless steel ferrules included. For 1/16" OD tubing.

Zero-Dead-Volume Valco Internal Tee

More Details
Connect three lines. 300 series stainless steel; stainless steel ferrules included. For 1/16" OD tubing.

Zero-Dead-Volume Valco Internal Reducing Union

More Details
Connect two sizes of tubing, using zero-dead-volume fittings on each end. For 1/8" to 1/16" OD tubing. Stainless steel ferrules included.

MXT Low Dead Volume "Y" Connector Kits for Metal Columns

More Details
Connect two MXT columns to one inlet or one MXT column to two detectors.

Each kit contains the MXT union, three 1/32-inch ferrules and nuts.

Polyimide Resin

More Details
Securely connects a Press-Tight connector to a fused silica column.

Max Temp: 350 °C

GRAPHPACK 3D/2 Ferrules

More Details
GRAPHPACK technology provides a complete system that quickly and reliably makes a leak-tight, low-dead-volume connection. The central component is a metal-jacketed graphite ferrulethe ideal seal for GC applications.

GRAPHPACK 2M Ferrules

for Gerstel CIS 3 and CIS 4 PTV Inlets

Nuts & Ferrules for Valco Connectors (1/16-Inch Stainless Steel)

More Details
Restek offers a selected line of Valco fittings for connecting fused silica or 1/16- or 1/8-inch metal tubing. Valco fittings have been designed for the specific demands of instrumentation and manufactured with the tight tolerances and premium quality that analysts require. If you don’t see the Valco fitting you need, please request special ordering information.

1/16-Inch Valco Adaptor Ferrules

More Details
Fused silica adaptor ferrules are made from Valcon polyimide, a unique, graphite-reinforced composite specially prepared to maximize mechanical stability at temperatures up to 350 °C. The determining factor for selecting adaptor ferrule size is the fused silica tubing OD.

1/32-Inch Valco Adaptor Ferrules (Valcon Polyimide)

More Details
Fused silica adaptor ferrules are made from Valcon polyimide, a unique, graphite-reinforced composite specially prepared to maximize mechanical stability at temperatures up to 350 °C. The determining factor for selecting adaptor ferrule size is the fused silica tubing OD.

1/4-Inch3/16-Inch Open-End Wrenches

More Details
High-quality miniature wrenches to use with MXT low-dead-volume connectors.

Gerstel GRAPHPACK 3D/2 Connectors

More Details
GRAPHPACK technology provides a complete system that quickly and reliably makes a leak-tight, low-dead-volume connection. The central component is a metal-jacketed graphite ferrulethe ideal seal for GC applications.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us