EXP Reusable Fittings for HPLC & UHPLC for 10-32 fittings and 1/16" tubing

EXP Hand-Tight Coupler

More Details
  • Hand-tight fitting style achieves effortless HPLC seals—no tools needed for a 8,700+ psi seal.
  • Both hand-tight and hex-head styles wrench tighten for reliable UHPLC use up to 20,000+ psi!
  • Patented ferrule can be installed repeatedly without compromising high-pressure seal.
  • Hybrid design combines the durability of titanium with the sealing ability of PEEK.
  • Cutting-edge system provides ZDV (zero dead volume) connection to any 10-32 female port.
  • Compatible with 1/16" PEEK and stainless steel tubing.

EXP Reusable Fittings for HPLC & UHPLC for 10-32 fittings and 1/16" tubing

EXP Hex-Head Fittings

More Details
  • Hand-tight fitting style achieves effortless HPLC sealsno tools needed for a 8,700+ psi seal.
  • Both hand-tight and hex-head styles wrench tighten for reliable UHPLC use up to 20,000+ psi!
  • Patented ferrule can be installed repeatedly without compromising high-pressure seal.
  • Hybrid design combines the durability of titanium with the sealing ability of PEEK.
  • Cutting-edge system provides ZDV (zero dead volume) connection to any 10-32 female port.
  • Compatible with 1/16" PEEK and stainless steel tubing.

EXP Reusable Fittings for HPLC & UHPLC for 10-32 fittings and 1/16" tubing

EXP Hand-Tight Fittings

More Details
  • Hand-tight fitting style achieves effortless HPLC seals—no tools needed for a 8,700+ psi seal.
  • Both hand-tight and hex-head styles wrench tighten for reliable UHPLC use up to 20,000+ psi!
  • Patented ferrule can be installed repeatedly without compromising high-pressure seal.
  • Hybrid design combines the durability of titanium with the sealing ability of PEEK.
  • Cutting-edge system provides ZDV (zero dead volume) connection to any 10-32 female port.
  • Compatible with 1/16" PEEK and stainless steel tubing.

EXP Reusable Fittings for HPLC & UHPLC for 10-32 fittings and 1/16" tubing

EXP Titanium Hybrid Replacement Ferrules

More Details
  • Hand-tight fitting style achieves effortless HPLC seals—no tools needed for a 8,700+ psi seal.
  • Both hand-tight and hex-head styles wrench tighten for reliable UHPLC use up to 20,000+ psi!
  • Patented ferrule can be installed repeatedly without compromising high-pressure seal.
  • Hybrid design combines the durability of titanium with the sealing ability of PEEK.
  • Cutting-edge system provides ZDV (zero dead volume) connection to any 10-32 female port.
  • Compatible with 1/16" PEEK and stainless steel tubing.

EXP2 Reusable Fittings for HPLC & UHPLC

for 10-32 fittings and 1/16" tubing

More Details
  • Unique nut driver allows easy 20,000+ psi seals without wrenches.*
  • Patented ferrule can be installed repeatedly without compromising high-pressure seal.
  • Precision design provides zero-dead-volume (ZDV) connection to any 10-32 port.
  • Compact design fits in tight spaces, perfect for small oven compartments and six-port injection valves.
  • Non-swaged ferrules mean vendor-specific tubing is not required.
  • Suitable for both HPLC and UHPLC.

    *Rated to 20,000+ psi (1,400 bar) and tested to 30,000 psi (2,068 bar).

PTFE Tubing

More Details
  • Chemically inert tubing available in 0.094" and 0.063" IDs.
  • 1/8" OD in 3- and 10-meter lengths.
  • Easily cut to length using Clean-Cut Tubing Cutter (cat.# 25069).
  • Maximum temperature: 100 °C.
  • 1/4-28 threads for use on Mobi-Cap or Hub-Cap bottle tops.

Flexible Premium Grade Stainless Steel Tubing

More Details
  • Ideal for all plumbing in UHPLC systems.
  • 1/32" OD tubing with 17 mm long, 1/16" laser-welded ends.
  • Color bands for easy identification.
  • 316 stainless steel.
  • Tolerances: +/– 0.05 mm (.002") OD & +/– 0.025 mm (.001") ID.

Stainless Steel Tubing

More Details
  • Ideal for all plumbing in UHPLC systems.
  • 1/16" OD in 3- and 10-meter coiled lengths.
  • 316 stainless steel.
  • Standard-grade tolerances: +/– 0.05 mm (.002") OD & ID; premium-grade tolerances: +/– 0.05 mm (.002") OD & +/– 0.025 mm (.001") ID.

Stainless Steel Unions, Tees, and Crosses for UHPLC

More Details
  • Ideal for quickly and reliably connecting stainless steel tubing in UHPLC systems.
  • For 1/16" tubing on all 10-32 ports.
  • Body made of 316 stainless steel.
  • Includes 303 stainless steel nuts and 316 stainless steel ferrules.
  • Low dead volume.
  • Rated to 20,000 psi (1,375 bar).
  • 1/4" head on all nuts.

Stainless Steel Fittings for UHPLC

More Details
  • Ideal for connecting stainless steel tubing in UHPLC systems.
  • For 1/16" tubing on all 10-32 ports.
  • Ferrules must be purchased separately.
  • 1/4" head on all nuts.

PEEK Tubing

More Details
  • Ideal for plumbing to and inside HPLC systems.
  • 1/16" OD in 3- and 10-meter lengths.
  • Less oxygen permeable and more temperature resistant than PTFE or Tefzel tubing.
  • Easily cut to length using Clean-Cut Tubing Cutter (cat.# 25069).
  • Use with PEEK finger-tight or flangeless fittings.
  • Use tubing 0.007" to 7,000 psi; tubing 0.010" ID to 5,000 psi.

PEEK Unions, Tees, and Crosses for HPLC

More Details
  • Ideal for quickly and reliably connecting PEEK tubing in HPLC systems.
  • One-piece, finger-tight fittings—no ferrules required.
  • Low dead volume.
  • Included end fittings and body made of biocompatible PEEK.
  • Available in 0.25, 0.50, and 0.75 mm bore sizes.
  • Maximum temperature: 100 °C.
  • Rated to 5,000 psi (350 bar).
  • For 1/16" tubing on all 10-32 ports.

PEEK-HT Hex-Head Fittings for HPLC and UHPLC

More Details
  • One-piece design; no ferrule required.
  • Use included driver for wrench-free, 10,000 psi connections.
  • For 1/16" tubing on all 10-32 ports.
  • Made of proprietary, high-pressure, biocompatible PEEK.
  • Rated to 10,000 psi (689 bar).

PEEK Hex-Head Fittings for HPLC

More Details
  • One-piece design; no ferrule required.
  • For 1/16" tubing on all 10-32 ports.
  • Made of biocompatible PEEK.
  • Rated to 5,000 psi (350 bar).

PPS Hex-Head Fittings for HPLC

More Details
  • One-piece design; no ferrule required.
  • For 1/16" tubing on all 10-32 ports.
  • Made of polyphenylene sulfide (PPS).
  • Rated to 5,000 psi (350 bar).

PEEK Column Couplers

More Details
  • Connect two columns, a guard holder to a column, or inline sample prep holders.
  • One-piece, finger-tight design.
  • Self-adjusting to accommodate all 10-32 port depths.
  • Made of biocompatible PEEK.
  • Available in three IDs: 0.13, 0.17, or 0.25 mm.
  • Rated to 5,000 psi (350 bar).

Fittings and Ferrules for 1/8" & 1/16" Tubing

More Details
  • Ideal for safely and securely connecting PTFE tubing to Mobi-Cap bottle tops.

LC Stainless Steel Capillary Tubing

More Details
  • 316-grade stainless steel.
  • Precise precut lengths.
  • Clean and smooth surface finish.
  • Color coded for easy identification.
  • Tight tolerance: OD and ID +/-0.001".

Capillary Stainless Steel Tubing Assemblies

for Agilent HPLC Systems

More Details
  • Precut, micro-polished tubing and pre-seated fittings for quick, easy maintenance of your Agilent HPLC systems.
  • Meet or exceed manufacturer's performance.

Secure-Fit Fittings (Two Connectors)

More Details
A good connection between HPLC components is necessary for trouble-free chromatography. Secure-Fit connectors from Restek and Selerity Technologies ensure a consistent, leak-free sealand they eliminate excess dead volume! An internal spring mechanism holds the capillary tubing at the proper depth in the female fitting. This seal is maintained while you finger-tighten the nut.

Secure-Fit Fittings (Single Connectors)

More Details
A good connection between HPLC components is necessary for trouble-free chromatography. Secure-Fit connectors from Restek and Selerity Technologies ensure a consistent, leak-free sealand they eliminate excess dead volume! An internal spring mechanism holds the capillary tubing at the proper depth in the female fitting. This seal is maintained while you finger-tighten the nut.

1/16-Inch Stainless Steel Tube Fittings

More Details
Restek offers stainless steel tube fittings to help you maintain your HPLC equipment. Parker’s A-Lok two-piece ferrule design, along with NPT fittings, are ideal for modifying existing instrumentation or replacing worn connections.

Tubing Dressing Tool

More Details
Opens stainless steel tubing bore and removes burrs.

Clean-Cut Tubing Cutter

More Details
  • Burr-free, perpendicular cuts that will not distort the tubing OD or close the ID.
  • Use on PEEK, PTFE, Tefzel, and other polymeric tubing.
  • Individual holes for cutting 1/16", 2 mm, 3 mm, 1/8", and 4 mm tubing.

Universal 10-32 PEEK Column Connectors and Plugs

More Details
Universal PEEK connectors allow easy installation of all 1/16" tubing, including stainless steel, up to 5,000 psi (350 bar).

PEEK Tubing Elbows

More Details
Tubing elbows (90° and 180°) are ideal for routing 1/16" PEEK tubing through your system. Simply snap the tubing into the elbow. Prevent pinching of PEEK tubing, which can cause high pressure.

Tubing Clip

More Details
Securely holds 1/16" or 1/8" tubing in beaker, flask, or bottle up to 4 mm thick.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us