share:

Gas Generators

Parker H2PEMPD Hydrogen Generators

More Details
  • Proton exchange membrane (PEM) cell eliminates the need for liquid electrolytes.
  • Maintenance-free palladium purifier removes oxygen to <0.01 ppm and moisture to <1.0 ppm.
  • Produces continuous supply of 99.99999+% pure hydrogen gas.
  • Does not require downstream gas filters.
  • Maximum outlet pressures of 100 or 175 psig (690 or 1,200 kPa).
  • Automatic safety feature shuts the generator down if a hydrogen leak is detected.
  • Compact unit, requires only one square foot of bench space.
  • Warranty: one year from date of purchase on system and three years from date of purchase on cell life.

Parker Nitrogen Gas Generators for LC-MS

More Details
  • Turn compressed air into ultra-pure nitrogen (up to 99.5%).
  • Flows from 1 to 44 L/min.
  • Models N2-04, N2-14, N2-22, and N2-35 require no electricity.
  • Safe, reliable, low maintenance.
  • Maintenance kits include replacement filters.
  • 12-month warranty from date of purchase.

Parker PEM Hydrogen Generators

More Details
  • Proton exchange membrane (PEM) cell eliminates the need for liquid electrolytes.
  • Reliably generate 99.9995% pure hydrogen—for better chromatography.
  • Eliminates high-pressure cylinders—greater convenience and improved lab safety.
  • Compact unit, requiring only one square foot of bench space.
  • Quick and easy to service and maintain; unique display lighting changes color for easy status checks and water level indication.
  • Comes with a set of universal power adapters for U.S., European, and Asian plug types.
  • Automatic safety feature shuts the generator down if a hydrogen leak is detected.
  • Warranty: one year from date of purchase on system and two years from date of purchase on cell life.

Parker Model FID-1000 and FID-2500 Gas Stations

More Details
  • Single unit produces UHP zero air from house compressed air and 99.9995% pure hydrogen from deionized water.
  • Ideal for supplying up to 5-6 FIDs.
  • Eliminates inconvenient and dangerous gas cylinders.
  • Silent operation, minimal operator attention required.
  • 12-month warranty from date of purchase.

Parker Nitrogen Gas Generators

More Details
  • Produces ultra-pure nitrogen (up to 99.9999%).
  • Requires only a compressed air source and 110 volt AC power.
  • Typical applications include GC carrier gas, make-up gas, and low-flow sample concentrators.
  • Maintenance kits include replacement filters.
  • 12-month warranty from date of purchase.

Parker Zero Air Generators

More Details
  • Turn in-house compressed air into ultra-pure air (<0.1 ppm total hydrocarbons).
  • Remove hydrocarbons to less than 0.1 ppm by catalytic oxidation.
  • Operate at 40–125 psi (276–862 kPa).
  • Typical payback is less than one year, based on cylinder costs.
  • Install easily and take up little bench space.*
  • Maintenance kits include a one-year supply of prefilters and final filter.

Parker HydroGen Mate DI Water System

More Details
  • Economical means of providing deionized water to hydrogen generators, or for other uses.
  • Quick and easy installation; minimal maintenance.
  • Removes organics, phosphates, chlorine, and essentially all ionizable constituents from your water supply.
  • Easy-fill dispensing gun.
  • Visual indication for cartridge changes.
  • 12-month warranty from date of purchase.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us