Gas Purification

Click-On In-Line Super Clean Big Trap Replacement Filters

More Details
  • Largest-capacity traps available—run longer without replacing.
  • Maximum operating pressure of 11 bar (160 psig).
  • High-purity output ensures 99.9999% pure gas (maximum flow of 8 L/min).
  • Triple gas trap is ideal for purifying carrier gas.
  • Helium-specific triple gas trap is made for GC-MS—ready to use within 15 minutes of installation.
  • Hydrocarbon trap removes hydrocarbon contamination from carrier gas to help eliminate ghost peaks.
Note: Replacement filter only—fittings sold separately.

Click-On In-Line Super Clean Big Trap Filter Kits

More Details
  • Largest-capacity traps available—run longer without replacing.
  • "Quick connect" fittings with spring-loaded check valves allow filter replacement in seconds without tools or contamination.
  • Maximum operating pressure of 11 bar (160 psig).
  • High-purity output ensures 99.9999% pure gas (maximum flow of 8 L/min).
  • Triple gas trap is ideal for purifying carrier gas.
  • Helium-specific triple gas trap is made for GC-MS—ready to use within 15 minutes of installation.
  • Hydrocarbon trap removes hydrocarbon contamination from carrier gas to help eliminate ghost peaks.

Dynamic Duo (Restek Leak Detector and ProFLOW 6000 Flowmeter)

More Details
Protect your instrument and improve data quality with this powerful pair from Restek. Checking for leaks and verifying flows before you start running help you avoid costly problems later.

Click-On In-line Super Clean Ultra-High Capacity Oxygen Trap

More Details
Note: Replacement trap only—fittings sold separately.

Click-On In-line Super Clean Ultra-High Capacity Moisture Trap

More Details
Note: Replacement trap only—fittings sold separately.

Click-On In-line Super Clean Ultra-High Capacity Hydrocarbon Trap

More Details
Note: Replacement trap only—fittings sold separately.

Restek ProFLOW 6000 Electronic Flowmeter

More Details

Flowmeters that can measure flammable gases are becoming mandatory due to the increased use of hydrogen in chromatography. With its Ex rating, the Restek ProFLOW 6000 meter is designed specifically with explosive and flammable gases in mind.

The Restek ProFLOW 6000 is the only flowmeter you need for any type of chromatography gas measurement because of its wide range of capabilities. The ProFLOW 6000 is an electronic meter capable of measuring volumetric flow for most gases. Real-time measurements can be made for various types of flow paths, including continually changing gas types. This portable unit is designed for easy handheld use, and the stand adds benchtop convenience.


Restek Electronic Leak Detector

New and improved! Prevent small leaks from causing big problems with a Restek leak detector.

More Details
  • Detects a broad range of gases and indicates leak severity with both an LED display and audible tone.
  • No more waiting for a full charge—can be operated during charging or used up to 12 hours between charges.
  • Charging kit includes both universal AC power adaptor and USB charging cable so you can charge anywhere, anytime.
  • Pinpoint very small gas leaks quickly and accurately before they cause damage and downtime.
  • Compact, handheld unit is easy to operate and convenient to use anywhere you need to check for leaks.

Click-On In-Line Super Clean Indicator

More Details
  • Oxygen: green to grey
  • Moisture: beige to clear

Click-On In-Line Super Clean Replacement Gas Traps

More Details
Note: Replacement trap only—fittings sold separately.

Restek Click-On In-Line Super Clean Gas Traps and Connector Kits

More Details
  • High-purity output ensures 99.9999% pure gas.
  • Click-On fittings for easy, leak-tight cartridge changes; brass or stainless steel, 1/4" or 1/8".
  • Triple gas trap is ideal for purifying carrier gas—it contains oxygen, moisture, and hydrocarbon scrubbers in one cartridge.
  • Fuel gas trap is ideal for purifying flame ionization detector (FID) fuel gases, removing both moisture and hydrocarbons.
  • Helium-specific triple gas trap is ideal for GC-MS—it contains oxygen, moisture, and hydrocarbon scrubbers in one cartridge.

Helium-Specific Super Clean Filter and Kit

More Details
  • Specifically designed for purification of helium in GC-MS systems.
  • Traps are packed and conditioned using helium.
  • Uses standard single-position baseplate.

Carbon Dioxide Trap

More Details
  • Removes carbon dioxide from inert gases He, Ar, N2, H2, and clean dry air (CDA) to low ppb levels.
  • Functions by consuming carbon dioxide in a reaction with highly dispersed NaOH on a silicate support (reaction produces water which remains adsorbed in the purifier).
  • In highly critical applications, consider using an additional moisture trap after the CO2 trap as a safety measure.

Indicating Detector Gas Purifier

More Details
  • Removes moisture and hydrocarbons (C5 and heavier) from dry air or inert gases.
  • Indicator signals breakthrough by changing from yellowish green to blue at low relative humidity to warn of leaks in the gas stream.
  • The inner glass tube contains activated carbon, moisture indicator, and molecular sieve.
  • 10 μm frits at both ends of the filter.
  • Heavy-walled inner glass tube is protected by a sealed outer plastic tube to further protect against leaks.

Indicating Carrier Gas Purifier

More Details
  • Removes multiple impurities such as O2, H2O, CO2, CO, halogenated compounds, siloxanes, hydrocarbons (heavier than butane), sulfur-containing molecules, and ammonia from inert gases (He, Ar, N2, and H2).
  • Can be used with other filters to provide endpoint detection.
  • Contains highly sensitive visual indicators for oxygen and water contamination. The oxygen indicator signals breakthrough when the adsorbent changes from green to grey, and the moisture indicator signals breakthrough by changing from blue to brown.
  • Heavy-walled inner glass tube is protected by a sealed outer plastic tube to further protect against leaks.

Electronic Maintenance Indicators for Gas Filters

More Details
  • Audiovisual warning system ensures maintenance is done on time.
  • Progressively displays gas filter status, preventing unplanned downtime for maintenance.
  • Can be custom configured to your replacement/maintenance schedule.

Restek Super Clean Ultra-High Capacity Oxygen Filter

More Details

Restek Super Clean ultra-high capacity oxygen filter cartridges feature easy-to-read indicators.

The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.


Restek Super Clean Ultra-High Capacity Moisture Filter

More Details

Restek Super Clean ultra-high capacity moisture filter cartridges feature easy-to-read indicators.

The indicator code is shown on every trap so there is no confusion determining when a trap needs to be replaced.


Click-On In-Line Super Clean Double Connector

More Details
Connects any Click-On trap to a Click-On indicator.

Click-On In-Line Super Clean Connectors

More Details
Click-On connectors allow you to change traps quickly, without introducing oxygen into your system.

Wall Mounting Bracket

More Details
Baseplates can be mounted by using screws and the mounting holes on the baseplate, or by using this optional wall mounting bracket.

Restek Super Clean Gas Trapping System for LC-MS

More Details
A Super Clean quick-change cartridge system efficiently removes hydrocarbons from nitrogen!
  • Designed for easy, hassle-free cartridge changes.
  • Up to 20 L of hydrocarbon-free nitrogen per minute.
  • Filters connected in parallel to handle high flows for LC-MS.

Gas Pressure Gauge Kit

More Details
  • Use an in-line pressure gauge to indicate when a thermal gas purifier getter tube should be replaced.
  • Includes 1/8" tee and 0–100 psi (0-689k Pa) gauge.

1/8-Inch to 1/4-Inch Tube End Reducer

More Details
To adapt 1/8" Super Clean baseplate fittings to 1/4" tubing, use 1/8" to 1/4" tube end reducers.

Replacement O-Rings for Cartridge Baseplates

More Details
Pack includes 10 large O-rings and 10 small O-rings.

Restek Super Clean Gas Filter Kits

More Details
  • High-purity output ensures 99.9999% pure gas (at max. flow of 2 L/min).
  • Designed for easy, hassle-free cartridge changes.
  • Glass inside to prevent diffusion; polycarbonate housing outside for safety.

Restek Filter Baseplates

More Details
  • End fittings available in brass or stainless steel.
  • Baseplates fit all stand-alone Super Clean gas filters offered.

Hydrocarbon S-Trap

More Details
  • Removes hydrocarbons and other contaminants.
  • Reduces organics to 0.1 ppm (assuming 100 ppm input).
  • Each individually activated to ensure maximum efficiency.
  • Fits in GC oven for easy thermal recharging.
  • Maximum operating pressure: 60 psi (414 kPa).

ECD Vent Trap

More Details
  • Reduces the release of hazardous materials from the ECD vent into the lab.
  • Includes connecting lines and mounting kit.

VICI Mat/Sen Gas-Specific Purifier Modules

More Details
  • Replace separate traps for removing impurities (e.g., moisture and hydrocarbons) with one multiple-bed purifier that is designed specifically for purifying helium, hydrogen, nitrogen, or air.
  • Reduce gas impurities from ppm to low ppb levels.
  • Decrease baseline noise and increase GC-MS sensitivity.
  • Pre-purged with the specified gas to shorten downtime.

High-Capacity Split Vent Trap

More Details
  • Reduces the release of hazardous materials from the capillary split vent into the lab.
  • Includes connecting lines and mounting kit.

Refillable Hydrocarbon Trap

More Details
  • Removes trace impurities from carrier gas.
  • Reduces organics to 0.1 ppm (assuming 100 ppm input).
  • 60 µm frit prevents gas contamination by purifier particles.
  • Good for purge-and-trap systems.
  • Refillable and rechargeable.
  • Maximum operating pressure: 125 psig (862 kPa).
  • Maximum flow: 5 L/min.

Capillary-Grade Hydrocarbon Trap

More Details
  • Packed with an extremely high surface area, baked coconut shell–based activated carbon.
  • Purged with ultra-high-purity helium; ready to use with any carrier gas including hydrogen.
  • Reduces organics to 0.1 ppm (assuming 100 ppm input).
  • Maximum operating pressure: 250 psi (1,724 kPa).

Indicating Moisture Trap

More Details
  • Reduces water to less than 10 ppb. Indicator changes from yellowish green to blue at 5% relative humidity (suitable for general use).
  • Pre-purged for fast stabilization.
  • Reduces noise from high-sensitivity detectors.
  • Heavy-walled glass body prevents oxygen and water infusion.
  • 10 μm frit prevents microparticulate damage to needle valves and flow controllers.
  • Maximum operating pressure: 100 psi (689 kPa).

High-Capacity Moisture Trap

More Details
  • Purged with ultra-high-purity helium; ready to use with any carrier gas including hydrogen.
  • Reduces water to less than 15 ppb.
  • Maximum operating pressure: 250 psi (1,724 kPa).
  • Maximum flow: 1.25 L/min.

Molecular Sieve S-Trap

More Details
  • Traps water vapor; increases column and oxygen trap lifetime.
  • Reduces baseline noise from sensitive detectors such as ECDs and mass spectrometers.
  • Activated and ready to use.
  • Reduces water to less than 1 ppm.
  • Maximum flow: 1 L/min.

High-Capacity Oxygen Trap

More Details
  • Removes up to 135 ml of oxygen or 2 g of water.
  • Long life—typically purifies more than 480 cu ft of inert gas.
  • Reduces oxygen to 15 ppb.
  • Maximum operating pressure: 250 psi (1,724 kPa).
  • Flow: 3 L/min @ 32 psi (221 kPa).

Replacement Chemical Traps and Parts

for Agilent GCs

More Details
  • Easy to install.
  • Attach to same fittings as original manufacturer's equipment.

Indicating Oxygen Trap

More Details
  • Removes oxygen to low ppb levels from He, Ar, N2, or methane.
  • Indicator changes from green to gray when adsorption capacity is depleted.
  • Can be used with nonoxidizing gases such as He, Ar, N2, H2, or CH4.
  • Heavy-walled inner glass tube is protected by a sealed outer plastic tube to prevent oxygen and water infusion.
  • Prepurged for fast stabilization.
  • 100 psi (689 kPa) maximum operating pressure.
  • Reduces oxygen to 100 ppb.
  • 10 µm frits at inlet and outlet.
  • Optimal flow rate: < 150 mL/min.

Restek Gas Management System

More Details
  • Removes moisture, hydrocarbons, and oxygen from carrier gas, extending column lifetime.
  • Produces high-purity carrier gas for most applications.
  • Includes one each: moisture, hydrocarbon, and indicating oxygen trap.
  • Replacing traps is safe and easy.
  • Maximum flow: 150 cc/min for optimal performance.

Charging Accessories for Restek Electronic Leak Detector (cat.# 28500)

More Details
For current leak detector model only (cat.# 28500); not compatible with legacy model (cat.# 22655).

Small Probe Adaptor for Restek Electronic Leak Detector

More Details
Compatible with both current (cat.# 28500) and legacy (cat.# 22655) leak detector models.

Replacement Gas Filters for Restek Super Clean Gas Filter Kits

More Details
  • High-purity output ensures 99.9999% pure gas (at max. flow of 2 L/min).
  • Designed for easy, hassle-free cartridge changes.
  • Glass inside to prevent diffusion; polycarbonate housing outside for safety.
  • All traps measure 10 5/8" x 1 3/4" (27 x 4.4 cm).

Soft-Sided Storage Case for Restek Leak Detector or ProFLOW 6000 Electronic Flowmeter

More Details

Optional soft-sided storage case is ideal for storing your leak detector or flowmeter in smaller spaces, such as your toolbox.

Compatible with both current (cat.# 28500) and legacy (cat.# 22655) leak detector models.


Power Adaptors for Legacy Restek Electronic Leak Detector (cat.# 22655)

More Details
For legacy leak detector model only (cat.# 22655); not compatible with current model (cat.# 28500).

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us