ASTM Petrochemical Method Chromatography Product Guide
Proven, Integrated Solutions and Veteran
Expertise for Your Petrochemical &
Chemical Analyses
Restek is your ideal partner for integrated petrochemical solutions, and the following ASTM method product guide will help you quickly pick the right GC columns and reference standards for SimDist, DHA, finished gasoline, and other common petroleum analyses.
If you have any questions or need more information, visit www.restek.com/petro for additional resources or to contact one of our in-house petroleum experts for assistance.
(High-Temperature) Simulated Distillation (SimDist) | ||||
Method # |
Method Title |
Restek Column(s) |
Restek Reference |
Chromatogram# |
D2887 |
Standard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5–C44) |
MXT-2887, Siltek-treated stainless steel or MXT-1HT SimDist, Siltek-treated stainless steel or Rtx-2887 Column |
ASTM D2887-12 Calibration Standards Polywax Standards D2887 Calibration Mix |
|
D2887B Accelerated |
Standard Test Method for Boiling Range Distribution of Petroleum Fractions by Gas Chromatography (C5–C44) |
MXT-1HT SimDist Column or MXT-1HT SimDist Column |
ASTM D2887-12 Calibration Standards Polywax Standards D2887 Calibration Mix |
|
D7213 |
Standard Test Method for Boiling Range Distribution of Petroleum Distillates in the Boiling Range from 100 to 615 °C by Gas Chromatography (C5–C60) |
MXT-1HT SimDist, Siltek-treated stainless steel or MXT-1HT SimDist, Siltek-treated stainless steel or MXT-1HT SimDist, Siltek-treated stainless steel |
||
D6352 |
Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700 °C by Gas Chromatography (C10–C90) |
MXT-1HT SimDist, Siltek-treated stainless steel or MXT-1HT SimDist, Siltek-treated stainless steel |
Polywax Standards |
|
D7398 |
Standard Test Method for Boiling Range Distribution of Fatty Acid Methyl Esters (FAME) in the Boiling Range from 100 to |
MXT-1HT SimDist, Siltek-treated stainless steel |
Polywax Standards |
|
D7500 |
Standard Test Method for Determination of Boiling Range Distribution of Distillates and Lubricating Base Oils in Boiling Range from 100 to 735 °C by Gas Chromatography (C7–C110) |
MXT-1HT SimDist, Siltek-treated stainless steel or MXT-1HT SimDist, Siltek-treated stainless steel |
Polywax Standards |
|
D7169 |
Standard Test Method for Boiling Point Distribution of Samples with Residues Such as Crude Oils and Atmospheric and Vacuum Residues by High-Temperature Gas Chromatography |
MXT-1HT SimDist, Siltek-treated stainless steel or MXT-1HT SimDist, Siltek-treated stainless steel |
Polywax Standards |
|
D7096 (replaces D3710) |
Standard Test Method for Determination of the Boiling Range Distribution of Gasoline by Wide-Bore Capillary Gas Chromatography |
MXT-1, Siltek-treated stainless steel or MXT-1, Siltek-treated stainless steel |
or D3710-95 Calibration Mix |
|
Detailed Hydrocarbon Analysis (DHA) |
||||
Method # |
Method Title |
Restek Column(s) |
Restek Reference |
Chromatogram# |
D5134 |
Standard Test Method for Detailed Analysis of Petroleum Naphthas through n-Nonane by Capillary Gas Chromatography |
Rtx-DHA-50 |
||
D6729 |
Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100-Meter Capillary High-Resolution Gas Chromatography |
Rtx-DHA-100 |
DHA Standards |
|
D6730 |
Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 100–Meter Capillary (with precolumn) High-Resolution Gas Chromatography |
Rtx-DHA-100 and Rtx-5 DHA Tuning |
DHA Standards |
|
D6733 |
Standard Test Method for Determination of Individual Components in Spark Ignition Engine Fuels by 50-Meter Capillary High-Resolution Gas Chromatography |
Rtx-DHA-50 |
DHA Standards |
|
Finished Gasoline |
||||
Method # |
Method Title |
Restek Column(s) |
Restek Reference |
Chromatogram# |
D3606 |
Standard Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline by Gas Chromatography |
D3606 Application 2-Column Set Specified in the D3606 method addendum — includes: - Rtx-1 and - proprietary packing |
D3606 Standards |
|
D4815 |
Standard Test Method for Determination of MTBE, ETBE, TAME, DIPE, tertiary-Amyl Alcohol, and C1 to C4 Alcohols in Gasoline by Gas Chromatography (Oxygenates) |
Micropacked with 20% TCEP on 80/100 Chromosorb PAW and Rtx-1 |
||
D5580 |
Standard Test Method for Determination of Benzene, Toluene, Ethylbenzene, p/m-Xylene, o-Xylene, C9 and Heavier Aromatics, and Total Aromatics in Finished Gasoline by Gas Chromatography |
Micropacked with 20% TCEP on 80/100 Chromosorb PAW and Rtx-1 |
|
|
D5501 |
Standard Test Method for Determination of Ethanol Content of Denatured Fuel Ethanol by Gas Chromatography |
Rtx-DHA-150 or Rtx-DHA-100 |
||
D8071 |
Standard Test Method for Determination of Hydrocarbon Group Types and Select Hydrocarbon and Oxygenate Compounds in Automotive Spark-Ignition Engine Fuel Using Gas Chromatography with Vacuum Ultraviolet Absorption Spectroscopy Detection (GC-VUV) |
Rxi-1ms |
||
Biodiesel |
||||
Method # |
Method Title |
Restek Column(s) |
Restek Reference |
Chromatogram# |
D6584 |
Test Method for Determination of Free and Total Glycerin in B-100 Biodiesel Methyl Esters by Gas Chromatography |
MXT-Biodiesel TG, Siltek-treated stainless steel or MXT-Biodiesel TG, Siltek-treated stainless steel or Rtx-Biodiesel TG |
Biodiesel Standards |
|
Jet Fuel |
||||
Method # |
Method Title |
Restek Column(s) |
Restek Reference |
Chromatogram# |
D8267 |
Standard Test Method for Determination of Saturated Hydrocarbon, Aromatic, and Diaromatic Content of Aviation Turbine Fuels Using Gas Chromatography with Vacuum Ultraviolet Absorption Spectroscopy Detection (GC-VUV) |
Rxi-1ms |
||
Natural Gas |
||||
Method # |
Method Title |
Restek Column(s) |
Restek Reference |
Chromatogram# |
D1945 |
Standard Test Method for Analysis of Natural Gas by Gas Chromatography |
MXT-Msieve 5A, Siltek-treated stainless steel and MXT-Q-BOND, Siltek-treated stainless steel |
Natural Gas Standards |
|
Refinery Gas |
||||
Method # |
Method Title |
Restek Column(s) |
Restek Reference |
Chromatogram# |
D2163 |
Standard Test Method for Determination of Hydrocarbons in Liquefied Petroleum (LP) Gases and Propane/Propene Mixtures by Gas Chromatography |
Rt-Alumina BOND/Na2SO4 |
Refinery Gas Standards |
|
UOP 539 |
Standard Practice for Analysis of Reformed Gas by Gas Chromatography |
2abc Refinery Gas Packed Column Set or MXT-Msieve 5A, Siltek-treated stainless steel and MXT-Q-BOND, Siltek-treated stainless steel |
||
Impurities |
||||
Method # |
Method Title |
Restek Column(s) |
Restek Reference |
Chromatogram# |
D2593 |
Standard Test Method for Butadiene Purity and Hydrocarbon Impurities by Gas Chromatography |
Rt-Alumina BOND/MAPD |
Refinery Gas Standard #5 |
|
D2712 |
Standard Test Method for Hydrocarbon Traces in Propylene Concentrates by Gas Chromatography |
Rt-Alumina BOND/KCl |
Refinery Gas Standard #5 |
|
D6159 |
Standard Test Method for Determination of Hydrocarbon Impurities in Ethylene by Gas Chromatography |
Rt-Alumina BOND/KCl and Rtx-1 |
Refinery Gas Standard #5 |
|
D5441 |
Standard Test Method for Analysis of Methyl Tert-Butyl Ether (MTBE) by Gas Chromatography |
Rtx-DHA-100 or Rtx-DHA-50 or Rtx-DHA-150 |
||
Sulfur |
||||
Method # |
Method Title |
Restek Column(s) |
Restek Reference |
Chromatogram# |
D6228 |
Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Flame Photometric Detection |
Rtx-1 or MXT--1, Siltek-treated stainless steel or Rtx-1 |
||
D5623 |
Standard Test Method for Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection |
Rtx-1 |
||
Industrial Chemicals |
||||
Method # |
Method Title |
Restek Column(s) |
Restek Reference |
Chromatogram# |
D5917 |
Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and External Calibration |
Stabilwax |
||
D7266 |
Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (External Standard) |
Rtx-DHA-100 |
||
D7504 |
Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and Effective Carbon Number |
Stabilwax |
||
D7871 |
Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (Effective Carbon Number) |
Rtx-DHA-100 |
||
D7011 |
Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection |
Rtx-WAX |
||
D6144 |
Standard Test Method for Analysis of AMS (a-Methylstyrene) by Capillary Gas Chromatography |
Rtx-1 |
||
D7057 |
Standard Test Method for Analysis of Isopropylbenzene (Cumene) by Gas Chromatography (External Standard) |
Rtx-1 |
If you have any questions about Restek Refined or need more information, visit www.restek.com/petro for additional resources or to contact one of our in-house petroleum experts for assistance.