share:

Instruction Sheets
Ordering Notes
Selected Product See All Options
Cat.#:
List Price:$0.00
Unit:
Shopping Cart functionality available on Desktop Version of website.
Select a Product Show Selected
Catalog #Product NameLengthIDdfColumn ConfigUnits
Catalog #
71811
Product Name
MXT-1
Length
10 m
ID
0.18 mm
df
0.20 μm
Column Config
Units
ea.
Catalog #
71812
Product Name
MXT-1
Length
20 m
ID
0.18 mm
df
0.20 μm
Column Config
Units
ea.
Catalog #
71815
Product Name
MXT-1
Length
20 m
ID
0.18 mm
df
0.40 μm
Column Config
Units
ea.
Catalog #
70105
Product Name
MXT-1
Length
15 m
ID
0.25 mm
df
0.10 μm
Column Config
Units
ea.
Catalog #
70116
Product Name
MXT-1
Length
30 m
ID
0.25 mm
df
0.10 μm
Column Config
Units
ea.
Catalog #
70120
Product Name
MXT-1
Length
15 m
ID
0.25 mm
df
0.25 μm
Column Config
Units
ea.
Catalog #
70123
Product Name
MXT-1
Length
30 m
ID
0.25 mm
df
0.25 μm
Column Config
Units
ea.
Catalog #
70126
Product Name
MXT-1
Length
60 m
ID
0.25 mm
df
0.25 μm
Column Config
Units
ea.
Catalog #
70129
Product Name
MXT-1
Length
105 m
ID
0.25 mm
df
0.25 μm
Column Config
Units
ea.
Catalog #
70135
Product Name
MXT-1
Length
15 m
ID
0.25 mm
df
0.50 μm
Column Config
Units
ea.
Catalog #
70138
Product Name
MXT-1
Length
30 m
ID
0.25 mm
df
0.50 μm
Column Config
Units
ea.
Catalog #
70150
Product Name
MXT-1
Length
15 m
ID
0.25 mm
df
1.00 μm
Column Config
Units
ea.
Catalog #
70153
Product Name
MXT-1
Length
30 m
ID
0.25 mm
df
1.00 μm
Column Config
Units
ea.
Catalog #
70156
Product Name
MXT-1
Length
60 m
ID
0.25 mm
df
1.00 μm
Column Config
Units
ea.
Catalog #
70159
Product Name
MXT-1
Length
105 m
ID
0.25 mm
df
1.00 μm
Column Config
Units
ea.
Catalog #
70102
Product Name
MXT-1
Length
6 m*
ID
0.28 mm
df
0.10 μm
Column Config
Units
ea.
Catalog #
70106
Product Name
MXT-1
Length
15 m
ID
0.28 mm
df
0.10 μm
Column Config
Units
ea.
Catalog #
70109
Product Name
MXT-1
Length
30 m
ID
0.28 mm
df
0.10 μm
Column Config
Units
ea.
Catalog #
70121
Product Name
MXT-1
Length
15 m
ID
0.28 mm
df
0.25 μm
Column Config
Units
ea.
Catalog #
70124
Product Name
MXT-1
Length
30 m
ID
0.28 mm
df
0.25 μm
Column Config
Units
ea.
Catalog #
70139
Product Name
MXT-1
Length
30 m
ID
0.28 mm
df
0.50 μm
Column Config
Units
ea.
Catalog #
70139-273
Product Name
MXT-1
Length
30 m
ID
0.28 mm
df
0.50 μm
Column Config
3.5" Coil
Units
ea.
Catalog #
70142
Product Name
MXT-1
Length
60 m
ID
0.28 mm
df
0.50 μm
Column Config
Units
ea.
Catalog #
70151
Product Name
MXT-1
Length
15 m
ID
0.28 mm
df
1.00 μm
Column Config
Units
ea.
Catalog #
70154
Product Name
MXT-1
Length
30 m
ID
0.28 mm
df
1.00 μm
Column Config
Units
ea.
Catalog #
70154-600
Product Name
MXT-1
Length
30 m
ID
0.28 mm
df
1.00 μm
Column Config
Units
6-pk.
Catalog #
70157
Product Name
MXT-1
Length
60 m
ID
0.28 mm
df
1.00 μm
Column Config
Units
ea.
Catalog #
70181
Product Name
MXT-1
Length
15 m
ID
0.28 mm
df
3.00 μm
Column Config
Units
ea.
Catalog #
70184
Product Name
MXT-1
Length
30 m
ID
0.28 mm
df
3.00 μm
Column Config
Units
ea.
Catalog #
70187
Product Name
MXT-1
Length
60 m
ID
0.28 mm
df
3.00 μm
Column Config
Units
ea.
Catalog #
70101
Product Name
MXT-1 SimDist
Length
6 m
ID
0.53 mm
df
0.15 μm
Column Config
Units
ea.
Catalog #
70107
Product Name
MXT-1
Length
15 m
ID
0.53 mm
df
0.15 μm
Column Config
Units
ea.
Catalog #
70122
Product Name
MXT-1
Length
15 m
ID
0.53 mm
df
0.25 μm
Column Config
Units
ea.
Catalog #
70125
Product Name
MXT-1
Length
30 m
ID
0.53 mm
df
0.25 μm
Column Config
Units
ea.
Catalog #
70128
Product Name
MXT-1
Length
60 m
ID
0.53 mm
df
0.25 μm
Column Config
Units
ea.
Catalog #
70137
Product Name
MXT-1
Length
15 m
ID
0.53 mm
df
0.50 μm
Column Config
Units
ea.
Catalog #
70140
Product Name
MXT-1
Length
30 m
ID
0.53 mm
df
0.50 μm
Column Config
Units
ea.
Catalog #
70143
Product Name
MXT-1
Length
60 m
ID
0.53 mm
df
0.50 μm
Column Config
Units
ea.
Catalog #
70152
Product Name
MXT-1
Length
15 m
ID
0.53 mm
df
1.00 μm
Column Config
Units
ea.
Catalog #
70155
Product Name
MXT-1
Length
30 m
ID
0.53 mm
df
1.00 μm
Column Config
Units
ea.
Catalog #
70155-271
Product Name
MXT-1
Length
30 m
ID
0.53 mm
df
1.00 μm
Column Config
6" Coil
Units
ea.
Catalog #
70158
Product Name
MXT-1
Length
60 m
ID
0.53 mm
df
1.00 μm
Column Config
Units
ea.
Catalog #
70158-271
Product Name
MXT-1
Length
60 m
ID
0.53 mm
df
1.00 μm
Column Config
6" Coil
Units
ea.
Catalog #
70167
Product Name
MXT-1
Length
15 m
ID
0.53 mm
df
1.50 μm
Column Config
Units
ea.
Catalog #
70170
Product Name
MXT-1
Length
30 m
ID
0.53 mm
df
1.50 μm
Column Config
Units
ea.
Catalog #
70173
Product Name
MXT-1
Length
60 m
ID
0.53 mm
df
1.50 μm
Column Config
Units
ea.
Catalog #
70182
Product Name
MXT-1
Length
15 m
ID
0.53 mm
df
3.00 μm
Column Config
Units
ea.
Catalog #
70185
Product Name
MXT-1
Length
30 m
ID
0.53 mm
df
3.00 μm
Column Config
Units
ea.
Catalog #
70188
Product Name
MXT-1
Length
60 m
ID
0.53 mm
df
3.00 μm
Column Config
Units
ea.
Catalog #
70189
Product Name
MXT-1
Length
105 m
ID
0.53 mm
df
3.00 μm
Column Config
Units
ea.
Catalog #
70177
Product Name
MXT-1
Length
15 m
ID
0.53 mm
df
5.00 μm
Column Config
Units
ea.
Catalog #
70177-273
Product Name
MXT-1
Length
15 m
ID
0.53 mm
df
5.00 μm
Column Config
3.5" Coil
Units
ea.
Catalog #
70179
Product Name
MXT-1
Length
30 m
ID
0.53 mm
df
5.00 μm
Column Config
Units
ea.
Catalog #
70179-273
Product Name
MXT-1
Length
30 m
ID
0.53 mm
df
5.00 μm
Column Config
3.5" Coil
Units
ea.
Catalog #
70183
Product Name
MXT-1
Length
60 m
ID
0.53 mm
df
5.00 μm
Column Config
Units
ea.
Catalog #
70183-273
Product Name
MXT-1
Length
60 m
ID
0.53 mm
df
5.00 μm
Column Config
3.5" Coil
Units
ea.
Catalog #
70191
Product Name
MXT-1
Length
15 m
ID
0.53 mm
df
7.00 μm
Column Config
Units
ea.
Catalog #
70192
Product Name
MXT-1
Length
30 m
ID
0.53 mm
df
7.00 μm
Column Config
Units
ea.
Catalog #
70193
Product Name
MXT-1
Length
60 m
ID
0.53 mm
df
7.00 μm
Column Config
Units
ea.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us