Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set

GC_EV1498

Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141-051), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324-051), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with universal angled “Y” Press-Tight connector (cat.# 20403-261)
Injector: Splitless
Detector: Micro-ECD

Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set

GC_EV1496

Column: Rtx-CLPesticides 30 m, 0.25 mm ID, 0.25 µm (cat.# 11123-051), and Rtx-CLPesticides2 30 m, 0.25 mm ID, 0.20 µm (cat.# 11323-051), using Rxi guard column 5 m, 0.25 mm ID (cat.# 10029), with universal angled “Y” Press-Tight connector (cat.# 20403-261)
Injector: Splitless
Detector: Micro-ECD

7-Minute Analysis of Organochlorine Pesticides (EPA Method 8081) on Rtx-CLPesticides and Rtx-CLPesticides2 Using Hydrogen

GC_EV1325

Column: Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), and Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with universal “Y” Press-Tight connector (cat.# 20406-261)
Injector: Splitless
Detector: Micro-ECD

Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides

GC_EV00636

Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.50 µm (cat.# 11139), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324)
Injector: Direct
Detector: ECD

Organochlorine Pesticides US EPA Method 8081 on Rtx-1701

GC_EV00409

Column: Rtx-1701, 30 m, 0.53 mm ID, 0.25 µm (cat.# 12025)
Injector: Direct
Detector: ECD

Organochlorine Pesticides US EPA Method 8081 on Rtx-440

GC_EV00733

Column: Rtx-440, 30 m, 0.32 mm ID, 0.50 µm (cat.# 12939), using IP Deactivated Guard Column 5 m, 0.32 mm ID (cat.# 10044)
Injector: Splitless
Detector: ECD

Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2 (0.32mm ID)

GC_EV00075A

Column: Rtx-CLPesticides2, 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324)
Injector: Direct
Detector: ECD

Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides (0.32mm ID)

GC_EV00075

Column: Rtx-CLPesticides, 30 m, 0.32 mm ID, 0.50 µm (cat.# 11139)
Injector: Direct
Detector: ECD

Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2 (0.53mm ID)

GC_EV00547B

Column: Rtx-CLPesticides2, 30 m, 0.53 mm ID, 0.42 µm (cat.# 11340)
Injector: Direct
Detector: ECD

Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides (0.53mm ID)

GC_EV00547A

Column: Rtx-CLPesticides, 30 m, 0.53 mm ID, 0.50 µm (cat.# 11140)
Injector: Direct
Detector: ECD

Organochlorine Pesticides US EPA Method 8081 on Rtx-35

GC_EV00079

Column: Rtx-35, 30 m, 0.32 mm ID, 0.50 µm (cat.# 10439)
Injector: Direct
Detector: ECD

Organochlorine Pesticides US EPA Method 8081 on Rtx-440

GC_EV00751

Column: Rtx-440, 30 m, 0.32 mm ID, 0.50 µm (cat.# 12939)
Injector: Splitless
Detector: ECD

Organochlorine Pesticides US EPA Method 8081 on Rtx-440

GC_EV00776

Column: Rtx-440, 30 m, 0.32 mm ID, 0.50 µm (cat.# 12939), using Siltek Guard Column 5 m, 0.32 mm ID (cat.# 10027), with SeCure “Y” Connector Kit (cat.# 20277)
Injector: Splitless
Detector: ECD

Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2

GC_EV00777

Column: Rtx-CLPesticides2, 30 m, 0.32 mm ID, 0.50 µm (cat.# 11325), using 5m, 0.32mm ID Siltek Guard Column 5 m, 0.32 mm ID (cat.# 10027), with SeCure “Y” Connector Kit (cat.# 20277)
Injector: Splitless
Detector: ECD

Organochlorine Pesticides by U.S. EPA Method 8081A on Rtx-CLPesticides2 (dual column w/ Rtx-440)

GC_EV00797

Column: Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.50 µm (cat.# 11325)
Injector: Splitless
Detector: ECD

Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-50

GC_EV00410

Column: Rtx-50, 30 m, 0.53 mm ID, 0.83 µm (cat.# 10569)
Injector: Direct
Detector: ECD

Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-5

GC_EV00408

Column: Rtx-5, 30 m, 0.53 mm ID, 0.50 µm (cat.# 10240)
Injector: Direct
Detector: ECD

Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-CLPesticides2

GC_EV00734

Column: Rtx-CLPesticides2, 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), using IP Deactivated Guard Column 5 m, 0.32 mm ID (cat.# 10044)
Injector: Splitless
Detector: ECD

Method 8081B Chlorinated Pesticides on Rtx-CLPesticides2

GC_EV1145

Column: Rtx-CLPesticides2, 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324)
Injector: Direct
Detector: ECD

Organochlorine Pesticides by EPA Method 8081A on Rtx-440 (dual column w/ Rtx-CLPesticides2)

GC_EV00796

Column: Rtx-440, 30 m, 0.32 mm ID, 0.50 µm (cat.# 12939)
Injector: Splitless
Detector: ECD

Organochlorine Pesticides by EPA Method 8081B on Rtx-CLPesticides/Rtx-CLPesticides2 (extended list)

GC_EV1193

Column: Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324), and Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with deactivated universal “Y” Press-Tight connector (cat.# 20405-261)
Injector: Splitless
Detector: Micro-ECD

Organochlorine Pesticides on Rtx-CLPesticides Columns (0.18 mm ID column set)

GC_EV00892

Column: Rtx-CLPesticides 20 m, 0.18 mm ID, 0.18 µm (cat.# 42102), and Rtx-CLPesticides2 20 m, 0.18 mm ID, 0.14 µm (cat.# 42302), using IP deactivated guard column 5 m, 0.53 mm ID (cat.# 10045), with SeCure “Y” connector kit with universal “Y” Press-Tight® connector (cat.# 20276)
Injector: Splitless
Detector: Micro-ECD

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us