Alkaloids on DiatoSorb-WHP Packed Column

GC_PC1291

Column: SilcoSmooth tubing, 100/120 mesh on DiatoSorb-WHP, 1m, 1/8in OD, 2 mm ID
Injector: On-Column
Detector: FID

Barbiturates on DiatoSorb WHP Packed Column

GC_PC1292

Column: SilcoSmooth tubing, 100/120 mesh on DiatoSorb WHP, 1m, 1/8in OD, 2 mm ID
Injector: On-Column
Detector: FID

Steroids on DiatoSorb WHP Packed Column

GC_PC1290

Column: SilcoSmooth tubing, 100/120 mesh on DiatoSorb WHP, 1m, 1/8in OD, 2 mm ID
Injector: On-Column
Detector: FID

Solvents on DiatoSorb-WHP Packed Column

GC_PH1176

Column: SilcoSmooth tubing, 100/120 mesh on DiatoSorb-WHP, 3m, 1/8in OD, 2 mm ID
Injector: On-Column
Detector: FID

Fatty Acids (C1-C7) on DiatoSorb-WHP Packed Column

GC_PC1289

Column: SilcoSmooth tubing, 100/120 mesh on DiatoSorb-WHP, 2m, 1/8in OD, 2 mm ID
Injector: On-Column
Detector: TCD

Sulfur Compounds in Headspace Sample of Mexican Beer on Rt-XLSulfur

GC_FF00483

Column: Rt-XLSulfur, 100/120 mesh, 1m, 0.95mm OD, 0.75 mm ID (cat.# 19806)
Injector: Headspace - Loop
Detector: SCD

Sulfur Compounds in Headspace Sample of Canadian Beer on Rt-XLSulfur

GC_FF00487

Column: Rt-XLSulfur, 100/120 mesh, 1m, 0.95mm OD, 0.75 mm ID (cat.# 19806)
Injector: Headspace - Loop
Detector: SCD

Sulfur Compounds in Beverage Grade CO2 Rt-XLSulfur

GC_FF00491

Column: Rt-XLSulfur, 100/120 mesh, 1m, 0.95mm OD, 0.75 mm ID (cat.# 19806)
Injector: Headspace - Loop
Detector: SCD, attn x 1

Sulfur Compounds in Headspace Sample of U.S. Beer on Rt-XLSulfur

GC_FF00494

Column: Rt-XLSulfur, 100/120 mesh, 1m, 0.95mm OD, 0.75 mm ID (cat.# 19806)
Injector: Headspace - Loop
Detector: SCD

Rum on CarboBlack B

GC_FF00111

Column: SilcoSmooth™ Tubing, 80/120 mesh on CarboBlack B, 2m, 1/8in. OD, 2 mm ID (cat.# 80105-800)
Injector: On-Column - Packed
Detector: FID

Scotch on CarboBlack B

GC_FF00113

Column: SilcoSmooth™ Tubing, 80/120 mesh on CarboBlack B, 2m, 1/8in. OD, 2 mm ID (cat.# 80105-800)
Injector: On-Column - Packed
Detector: FID

Chlorofluorocarbons 5% Krytox on 60/80 CarboBlack B

GC_CH00323

Column: SilcoSmooth™ stainless steel tubing, 60/80 mesh on CarboBlack B, 3.05m, 1/8in. OD, 2.1 mm ID (cat.# Custom)
Injector: On-Column - Packed
Detector: FID

Solvents on HayeSep Q

GC_CH00328

Column: Siltek-treated stainless steel tubing, 100/120 mesh on HayeSep Q, 2m, 1/16in. OD, 1.00 mm ID (cat.# 19017)
Injector: Direct
Detector: FID

Aromatics (Xylene Isomers /BTEX) on 5% Rt-1200/5% Bentone 34 on 100/120 Silcoport

GC_PC00193

Column: SilcoSmooth Tubing, 100/120 mesh on Silcoport , 2m, 1/8in. OD, 2 mm ID (cat.# 80129-800)
Injector: Direct
Detector: FID

Sim Dist by ASTM D3710 on Rtx-1 SimDist 2887 (calibration)

GC_PC00229

Column: SilcoSmooth Tubing, 25 inches-1, 1/8in. OD, 2 mm ID (cat.# 80000-800)
Injector: Not On-Column - Packed
Detector: FID

Sim Dist, ASTM D3710 (Gasoline) on Rtx-1 SimDist 2887

GC_PC00230

Column: SilcoSmooth Tubing, 25 inches-1, 1/8in. OD, 2 mm ID (cat.# 80000-800)
Injector: Not On-Column - Packed
Detector: FID

Refinery Gas C1 to C5 Using n-Octane on Res-Sil C Packing

GC_PC00372

Column: SilcoSmooth Tubing, 80/100 mesh on Res-Sil C, 20ft., 1/8in. OD, 2 mm ID (cat.# 80436-800)
Injector: Not On-Column - Packed
Detector: FID

Refinery Gas Using OPN on Res-Sil C Packing

GC_PC00373

Column: SilcoSmooth tubing, 80/100 mesh on Res-Sil C packing, 12ft., 1/8in. OD, 2 mm ID (cat.# 80437-800)
Injector: On-Column - Packed
Detector: FID

Refinery Gas Calibration Standard on Refinery Gas Packed Column Set

GC_PC00374

Column: Silcosteel® tubing (cat.# 88000-875)
Injector: On-Column - Packed
Detector: FID

Sulfur Compounds and Hydrocarbons on Rt-XLSulfur

GC_PC00436

Column: Siltek, 1m, 0.95mm OD, 0.75 mm ID (cat.# 19806)
Injector: Not On-Column - Packed
Detector: SCD/FID

Natural Gas ShinCarbon ST (Micropacked)

GC_PC00672

Column: SilcoSmooth tubing, 100/120 mesh on Shincarbon ST, 1m, 1/16-1 OD, 1.0 mm ID (cat.# 19809)
Injector: On-Column - Packed
Detector: FID

Chlorofluorocarbon Gases on ShinCarbon ST (micropacked)

GC_PC00673

Column: SilcoSmooth® tubing, 100/120 mesh on ShinCarbon ST, 1 m-1, 1/16-1 OD, 1.0 mm ID (cat.# 19809)
Injector: On-Column - Packed
Detector: FID

Permanent Gases on ShinCarbon ST (micropacked)

GC_PC00666

Column: ShinCarbon ST, 100/120 mesh, 2m, 1/16in. OD, 1.0 mm ID (cat.# 19808)
Injector: On-Column - Packed
Detector: HID

Gasoline on ASTM D3606 Application Column Set

GC_PC01121

Column: D3606 Application Column (2 column set) Column 1: 6' (1.8m), 1/8" OD, 2.0mm ID, nonpolar Rtx®-1; Column 2: 16' (4.9m), 1/8" OD, 2.0mm ID, proprietary packing material (cat.# 83606-800)
Injector: Direct
Detector: TCD

Permanent Gases and C1+C2 Hydrocarbons on ShinCarbon ST (micropacked)

GC_PC00665

Column: ShinCarbon ST, 100/120 mesh, 2m, 1/16in. OD, 1.0 mm ID (cat.# 19808)
Injector: On-Column - Packed
Detector: HID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us