Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Raptor C18[x]

Enter more terms to filter the results further.

EPA Method 537.1 on Raptor C18

LC_EV0560

Column: Raptor C18 (cat.# 9304A52), Dimensions:50 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Ultra-short Chain, Legacy, and Alternative PFAS on Raptor C18 in Reagent Water

LC_EV0555

Column: Raptor C18 (cat.# 9304A1E), Dimensions:100 mm x 3 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Perfluorinated Alkyl Acids (PFBS, PFOA, PFOS, and HFPO-DA/GenX) on Raptor C18 5 μm

LC_EV0553

Column: Raptor C18 (cat.# 9304552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Morpholine Fungicides on Raptor C18

LC_FS0520

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 50 °C
Detector: MS/MS

Perfluorinated Alkyl Acids on Raptor C18 by LC-MS/MS for EPA Method 537

LC_EV0548

Column: Raptor C18 (cat.# 9304552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Bile Acids with Isomer Separation in Human Plasma on Raptor C18 (1.8 μm) by LC-MS/MS

LC_CF0712

Column: Raptor C18 (cat.# 9304252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 60 °C
Detector: MS/MS

Bile Acids in Human Plasma on Raptor C18 (1.8 μm) by LC-MS/MS

LC_CF0711

Column: Raptor C18 (cat.# 9304252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 60 °C
Detector: MS/MS

Perfluorinated Compounds (PFCs) on Raptor C18 (1.8 μm)

LC_EV0540

Column: Raptor C18 (cat.# 9304252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Perfluorinated Compounds (PFCs) on Raptor C18 (1.8 μm)

LC_EV0547

Column: Raptor C18 (cat.# 9304252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Perfluorooctanoic Acid (PFOA) and Perfluorooctanesulfonic Acid (PFOS) on Raptor C18 by LC-MS/MS

LC_EV0536

Column: Raptor C18 (cat.# 9304512), Dimensions:100 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Multiclass Veterinary Antibiotics on Raptor C18 by LC-MS/MS

LC_FS0506

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C
Detector: MS/MS

Macrolide, Lincosamide, and Streptogramin Antibiotics on Raptor C18 by LC-MS/MS

LC_FS0502

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Amphenicol and Tetracycline Antibiotics on Raptor C18 by LC-MS/MS

LC_FS0504

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Quinolone Antibiotics on Raptor C18 by LC-MS/MS

LC_FS0505

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Penicillin, Cephalosporin, and Tetracycline Antibiotics on Raptor C18 by LC-MS/MS

LC_FS0500

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Sulfonamide Antibiotics on Raptor C18 by LC-MS/MS

LC_FS0501

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Barbiturate Drug Panel on Raptor C18 by LC-MS/MS

LC_CF0619

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Temperature: 50 °C
Detector: MS/MS

Flavonols on Raptor C18 by LC-MS/MS

LC_FF0557

Column: Raptor C18 (cat.# 9304552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Phenylurea Herbicides on Raptor C18

LC_EV0533

Column: Raptor C18 (cat.# 9304565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Temperature: 30 °C
Detector: PDA

Macrolide Antibiotics on Raptor C18 by LC-MS/MS

LC_CF0600

Column: Raptor C18 (cat.# 9304512), Dimensions:100 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS

Parabens on Raptor C18

LC_PH0531

Column: Raptor C18 (cat.# 9304512), Dimensions:100 mm x 2.1 mm ID, Particle Size: 5 µm, Temperature: 40 °C
Detector: PDA

Aldehyde-Ketone-DNPH TO-11A Calibration Mix on Raptor C18

LC_EV0532

Column: Raptor C18 (cat.# 9304A65), Dimensions:150 mm x 4.6 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: Waters Acquity PDA

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us