Permanent Gases and Nitrous Oxide on Rt-Alumina BOND/Na2SO4

GC_PC1344

Column: Rt-Alumina BOND/Na2SO4, 30 m, 0.53 mm ID, 10 µm (cat.# 19755)
Injector: Split
Detector: TCD

Refinery Gas on Rt-Alumina BOND/Na2SO4 (ASTM D2163-14)

GC_PC1309

Column: Rt-Alumina BOND/Na2SO4, 50 m, 0.53 mm ID, 10 µm (cat.# 19756)
Injector: Split
Detector: FID

Refinery Gas Hydrocarbons on Rt-Alumina BOND/Na2SO4

GC_PC01139

Column: Rt-Alumina BOND/Na2SO4, 30 m, 0.53 mm ID, 10 µm (cat.# 19755)
Injector: Split
Detector: FID

Propylene and C1-C5 Hydrocarbons on Rt-Alumina BOND/Na2SO4

GC_PC01142

Column: Rt-Alumina BOND/Na2SO4, 50 m, 0.53 mm ID, 10 µm (cat.# 19756)
Injector: Split
Detector: FID

Propane Camping Fuel on Rt-Alumina BOND/Na2SO4

GC_PC01084

Column: Rt-Alumina BOND/Na2SO4, 50 m, 0.53 mm ID, 10 µm (cat.# 19756)
Injector: Split
Detector: FID

Butane Lighter Fluid on Rt-Alumina BOND/Na2SO4

GC_PC01083

Column: Rt-Alumina BOND/Na2SO4, 50 m, 0.53 mm ID, 10 µm (cat.# 19756)
Injector: Split
Detector: FID

Natural Gas on Rt-Alumina BOND/Na2SO4

GC_PC01092

Column: Rt-Alumina BOND/Na2SO4, 50 m, 0.53 mm ID, 10 µm (cat.# 19756)
Injector: Split
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us