share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

fast GC[x]

Enter more terms to filter the results further.

16 Priority PAHs and Methylnaphthalenes on Rxi- 5Sil MS using the GC Accelerator Kit in a 208 V Oven

GC_EV1448

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-SIM

16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven

GC_EV1472

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-SIM

High Speed GC-MS of Carcinogenic Aryl Amines Resulting From Reductive Cleavage of Azo Dyes on Rxi-35Sil MS (Scan Mode)

GC_QA0096

Column: Rxi-35Sil MS, 15 m, 0.25 mm ID, 0.25 µm (cat.# 13820)
Injector: Split
Detector: MS-Scan

High Speed GC-MS-SIM of Carcinogenic Aryl Amines Resulting From Reductive Cleavage of Azo Dyes on Rxi-35Sil MS (SIM Mode)

GC_QA0098

Column: Rxi-35Sil MS, 15 m, 0.25 mm ID, 0.25 µm (cat.# 13820)
Injector: Split
Detector: MS-SIM

Patchouli Oil Fast GC/MS on Rtx-5

GC_FF00851

Column: Rtx-5, 10 m, 0.10 mm ID, 0.10 µm (cat.# 41201)
Injector: Split
Detector: MS-Scan

Bergamot Oil Fast GC/MS on Rtx-5

GC_FF00850

Column: Rtx-5, 10 m, 0.10 mm ID, 0.10 µm (cat.# 41201)
Injector: Split
Detector: MS-Scan

Hydrocarbons, C44-C100 MXT-1HT Sim Dist (fast GC)

GC_PC00531

Column: MXT-1HT SimDist, 5 m, 0.53 mm ID, 0.10 µm (cat.# 70100)
Injector: On-Column
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us