share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

fatty acids[x]

Enter more terms to filter the results further.

Fatty Acids (C1-C7) on DiatoSorb-WHP Packed Column

GC_PC1289

Column: SilcoSmooth tubing, 100/120 mesh on DiatoSorb-WHP, 2m, 1/8in OD, 2 mm ID
Injector: On-Column
Detector: TCD

Organic Acids Free Fatty Acids on Stabilwax-DA

GC_CH00283

Column: Stabilwax-DA, 30 m, 0.53 mm ID, 0.25 µm (cat.# 11025)
Injector: Direct
Detector: FID

Organic Acids Free Fatty Acids Stabilwax-DA

GC_CH00284

Column: Stabilwax-DA, 30 m, 0.53 mm ID, 0.25 µm (cat.# 11025)
Injector: Direct
Detector: FID

FAMEs (Polyunsaturated Fatty Acids, Animal Source) on MXT-WAX

GC_FF00117

Column: MXT-WAX, 30 m, 0.28 mm ID, 0.25 µm (cat.# 70624)
Injector: Split
Detector: FID

FAMEs (Polyunsaturated Fatty Acids, Animal Source) on Rtx-2330

GC_FF00119

Column: Rtx-2330, 30 m, 0.32 mm ID, 0.20 µm (cat.# 10724)
Injector: Split
Detector: FID

Fatty Acids (Free) on Stabilwax-DA (30m, 0.32mm ID, 0.25µm)

GC_FF00653

Column: Stabilwax-DA, 30 m, 0.32 mm ID, 0.25 µm (cat.# 11024)
Injector: Splitless
Detector: FID

Fatty Acids (Free) on Stabilwax-DA (30m, 0.25mm ID, 0.25µm)

GC_CH00280

Column: Stabilwax-DA, 30 m, 0.25 mm ID, 0.25 µm (cat.# 11023)
Injector: Split
Detector: FID

Fatty Acids (Free) on Rtx-200

GC_CH00282

Column: Rtx-200, 30 m, 0.25 mm ID, 0.25 µm (cat.# 15023)
Injector: Split
Detector: FID

Fatty Acids (Free) on Rtx-1

GC_CH00281

Column: Rtx -1, 30 m, 0.53 mm ID, 5.00 µm (cat.# 10179)
Injector: Direct
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us