Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MS, Overwrap at the Seam

GC_FF00459

Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653)
Injector: Purge and Trap Split
Detector: MS-Scan

Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MS

GC_FF00461

Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653)
Injector: Purge and Trap Split
Detector: MS-Scan

Food Packaging Volatiles by Purge & Trap GC/MS on Rtx-5MS

GC_FF00462

Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653)
Injector: Purge and Trap Split
Detector: MS-Scan

Sulfur Compounds in Headspace Sample of Canadian Beer on Rt-XLSulfur

GC_FF00487

Column: Rt-XLSulfur, 100/120 mesh, 1m, 0.95mm OD, 0.75 mm ID (cat.# 19806)
Injector: Headspace - Loop
Detector: SCD

Sulfur Compounds in Beverage Grade CO2 Rt-XLSulfur

GC_FF00491

Column: Rt-XLSulfur, 100/120 mesh, 1m, 0.95mm OD, 0.75 mm ID (cat.# 19806)
Injector: Headspace - Loop
Detector: SCD, attn x 1

Sulfur Compounds in Headspace Sample of U.S. Beer on Rt-XLSulfur

GC_FF00494

Column: Rt-XLSulfur, 100/120 mesh, 1m, 0.95mm OD, 0.75 mm ID (cat.# 19806)
Injector: Headspace - Loop
Detector: SCD

Nitrofuran Metabolites by LC-MS/MS on Ultra C18 Column

LC_0323

Column: Ultra C18 (cat.# 9174312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 30 °C
Detector: MS/MS triple quadrupole (Thermo Scientific Discovery)

Food Packaging Volatiles on Rtx-5MS

GC_FF00457

Column: Rtx-5MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 12653)
Injector: Purge and Trap Split
Detector: MS-Scan

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us