share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

permanent gases[x]

Enter more terms to filter the results further.

Permanent Gases on Rt-Msieve 5A (15 m x 0.53 mm x 50 μm)

GC_PC1347

Column: Rt-Msieve 5A, 15 m, 0.53 mm ID, 50 µm (cat.# 19721)
Injector: Split
Detector: TCD

Permanent Gases on Rt-Msieve 5A (15 m x 0.25 mm x 20 μm)

GC_PC1349

Column: Rt-Msieve 5A, 15 m, 0.25 mm ID, 20 µm (cat.# 19773)
Injector: Split
Detector: TCD

Permanent Gases on Rt-Msieve 5A (15 m x 0.32 mm x 30 μm)

GC_PC1348

Column: Rt-Msieve 5A, 15 m, 0.32 mm ID, 30 µm (cat.# 19720)
Injector: Split
Detector: TCD

Permanent Gases and Nitrous Oxide on Rt-Msieve 5A

GC_PC1346

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Split
Detector: TCD

Permanent Gases and Nitrous Oxide on ShinCarbon ST Micropacked Column

GC_PC1343

Column: ShinCarbon ST micropacked column, 100/120 mesh, 2 m, 1.00 mm ID (cat.# 19808)
Injector: Split
Detector: TCD

Permanent Gases and Nitrous Oxide on Rt-Alumina BOND/Na2SO4

GC_PC1344

Column: Rt-Alumina BOND/Na2SO4, 30 m, 0.53 mm ID, 10 µm (cat.# 19755)
Injector: Split
Detector: TCD

Permanent Gases and Nitrous Oxide on Rt-Q-BOND

GC_PC1345

Column: Rt-Q-BOND, 30 m, 0.53 mm ID, 20 µm (cat.# 19742)
Injector: Split
Detector: TCD

Permanent Gases on Capillary Rt-MSieve 5A

GC_PC1331

Column: Rt-Msieve 5A, 30 m, 0.32 mm ID, 30 µm (cat.# 19722)
Injector: Split
Detector: TCD

Permanent Gases on Molecular Sieve 5A and Molecular Sieve 13X

GC_PC00166

Column: Molesieve 5A 1 m, 2 mm ID (cat.# 80440-800), and Molesieve 13X 2 m, 2 mm ID (cat.# 80439-800)
Injector: Direct
Detector: TCD

Permanent Gases Rt-Q-BOND

GC_PC00169

Column: Rt-Q-BOND, 30 m, 0.32 mm ID, 10 µm (cat.# 19744)
Injector: Split
Detector: HP-μTCD

Permanent Gases on Rt-MSieve 5A PLOT

GC_PC00170

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Sample Valve
Detector: Valco® HID

Permanent Gases on MXT-Msieve 5A

GC_PC1182

Column: MXT-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 79723)
Injector: Split
Detector: μ-TCD

Permanent Gases on ShinCarbon ST (micropacked)

GC_PC00666

Column: ShinCarbon ST, 100/120 mesh, 2m, 1/16in. OD, 1.0 mm ID (cat.# 19808)
Injector: On-Column - Packed
Detector: HID

Permanent Gases Rt-Msieve 5A

GC_PC00898

Column: Rt-Msieve 5A, 30 m, 0.53 mm ID, 50 µm (cat.# 19723)
Injector: Sample Valve
Detector: Valco helium ionization detector

Permanent Gases and C1+C2 Hydrocarbons on ShinCarbon ST (micropacked)

GC_PC00665

Column: ShinCarbon ST, 100/120 mesh, 2m, 1/16in. OD, 1.0 mm ID (cat.# 19808)
Injector: On-Column - Packed
Detector: HID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us