share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

1301[x]

Enter more terms to filter the results further.

Rum on Rxi-1301Sil MS

GC_FF1279

Column: Rxi-1301Sil MS, 60 m, 0.25 mm ID, 1.00 µm (cat.# 16097)
Injector: Split
Detector: MS-Scan

Bourbon on Rxi-1301Sil MS

GC_FF1278

Column: Rxi-1301Sil MS, 60 m, 0.25 mm ID, 1.00 µm (cat.# 16097)
Injector: Split
Detector: MS-Scan

Scotch on Rxi-1301Sil MS

GC_FF1277

Column: Rxi-1301Sil MS, 60 m, 0.25 mm ID, 1.00 µm (cat.# 16097)
Injector: Split
Detector: MS-Scan

Glycol Ethers of Regulatory Importance on Rxi-1301Sil MS

GC_PC1280

Column: Rxi-1301Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 16094)
Injector: Split
Detector: MS-Scan

Comprehensive Glycol Ether Mix on Rxi-1301Sil MS

GC_PC1279

Column: Rxi-1301Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 16094)
Injector: Split
Detector: MS-Scan

Amino Acids (9-Fluorenylmethyl-Chloroformate Derivatives) on Raptor ARC-18

LC_FF0539

Column: Raptor ARC-18 (cat.# 9314A1E), Dimensions:100 mm x 3 mm ID, Particle Size: 2.7 µm, Temperature: 30 °C
Detector: Waters Acquity PDA

Dynamic Headspace USP <467> solvents on Rtx-1301 (G43)

GC_PH00811

Column: Rtx-1301 (G43), 30 m, 0.53 mm ID, 3.00 µm (cat.# 16085-126)
Injector: Headspace - Syringe Split
Detector: FID

Organic Volatile Impurities on Rtx-1301

GC_PH00257

Column: Rtx-1301, 30 m, 0.53 mm ID, 3.00 µm (cat.# 16085)
Injector: Split
Detector: FID

Effect of Liner Choice for Headspace Analysis Residual Solvents Class 2 Mix A on Rtx-1301 (G43)

GC_PH00912

Column: Rtx-624, 30 m, 0.32 mm ID, 1.80 µm (cat.# 10970)
Injector: Headspace - Loop
Detector: FID

Rum on Rtx-1301

GC_FF00110

Column: Rtx-1301, 60 m, 0.25 mm ID, 1.40 µm (cat.# 16016)
Injector: Split
Detector: FID

Scotch on Rtx-1301

GC_FF00112

Column: Rtx-1301, 60 m, 0.25 mm ID, 1.40 µm (cat.# 16016)
Injector: Split
Detector: FID

USP <467> Residual Solvents on Rtx-1301 (G43) by Static Headspace

GC_PH00810

Column: Rtx-1301 w/5m Integra-Guard, 30 m, 0.53 mm ID, 3.00 µm (cat.# 16085-126)
Injector: Headspace - Loop
Detector: FID

Chlorinated Disinfection Byproducts, Chlorinated Solvents, and Halogenated Pesticides by EPA 551.1 on Rtx-1301

GC_EV00758

Column: Rtx-1301, 30 m, 0.25 mm ID, 1.00 µm (cat.# 16053)
Injector: Splitless
Detector: ECD

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us