Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

527[x]

Enter more terms to filter the results further.

Eucalyptus Oil on Rtx-Wax

GC_FF1298

Column: Rtx-Wax, 30 m, 0.32 mm ID, 0.25 µm (cat.# 12424)
Injector: Split
Detector: FID

Cumene (Isopropylbenzene) on Rtx-1

GC_PC1350

Column: Rtx-1, 60 m, 0.32 mm ID, 1.00 µm (cat.# 10157)
Injector: Split
Detector: FID

Impurities in α-Methylstyrene on Rtx-1

GC_PC1351

Column: Rtx-1, 60 m, 0.32 mm ID, 1.00 µm (cat.# 10157)
Injector: Split
Detector: FID

16-Hr Laboratory Air Sample with radiello 165

LC_AR0508

Column: Raptor C18 (cat.# 9304A65), Dimensions:150 mm x 4.6 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: UV/Vis

PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14

GC_PC1330

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148)
Injector: Split
Detector: FID

Aromatics on Rtx-DHA-100 (ASTM D6729-14)

GC_PC1323

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148)
Injector: Split
Detector: FID

Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100

GC_PC1284

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148), using Rtx-5 DHA tuning column 2-5 m, 0.25 mm ID (cat.# 10165), with universal Press-Tight connectors (cat.# 20429)
Injector: Split
Detector: FID

GC Multiresidue Pesticide Standard #3-ONP on Rxi-5ms by GC-MS

GC_FS0602

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan

PCB Congener Mix (EPA Method 8082A) on the Rtx-PCB Column

GC_EV1398

Column: Rtx-PCB, 20 m, 0.18 mm ID, 0.18 µm (cat.# 41302)
Injector: Split
Detector: MS-scan (positive ion chemical ionization emulating EI [EI-CI source.u])

GCxGC-TOFMS Analysis of Multi-Pesticide Standard Using Rxi-5Sil MS and Rtx-200

GC_FF1241

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.3 m, 0.25 mm ID, 0.25 µm (cat.# 15124)
Injector: Splitless
Detector: MS-TOF

Reformate on Rtx-1

GC_PC00210

Column: Rtx-1, 105 m, 0.25 mm ID, 0.50 µm (cat.# 10144)
Injector: Split
Detector: FID

Gasoline Aromatics on Rtx-1

GC_PC00215

Column: Rtx-1, 60 m, 0.25 mm ID, 1.00 µm (cat.# 10156)
Injector: Split
Detector: MS-Scan

Gasoline Aromatics on Rtx-1

GC_PC00214

Column: Rtx-1, 60 m, 0.25 mm ID, 1.00 µm (cat.# 10156)
Injector: Split
Detector: MS-Scan

Explosives by EPA 8330B on Ultra C8 with Trident Direct Guard Column

LC_EV0526

Column: Ultra C8 (cat.# 9103565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 30 °C
Detector: Shimadzu Prominence SPD-M20A Diode array

16 hr Laboratory Air Sample with radiello 165

LC_GN0531

Column: Raptor C18 (cat.# 9304A65), Dimensions:150 mm x 4.6 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: UV/Vis

Organochlorine Pesticides, PCBs, and BFRs on Rxi-XLB and Rxi-17Sil MS (GCxGC-ECD)

GC_EV1243

Column: Rxi-XLB 30 m, 0.25 mm ID, 0.25 µm (cat.# 13723)Rxi-17Sil MS 1 m, 0.15 mm ID, 0.15 µm (cat.# 43820)
Injector: Splitless
Detector: Micro-ECD

PCBs and BFRs on Rxi-XLB and Rxi-17Sil MS (GCxGC)

GC_EV1237

Column: Rxi-XLB 30 m, 0.25 mm ID, 0.25 µm (cat.# 13723)Rxi-17Sil MS 1 m, 0.15 mm ID, 0.15 µm (cat.# 43820)
Injector: Splitless
Detector: Micro-ECD

Marijuana Pesticides by GCxGC on Rxi-5Sil MS and Rtx-200

GC_FF1205

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.3 m, 0.25 mm ID, 0.25 µm (cat.# 15020)
Injector: Splitless
Detector: TOFMS

Pesticides and Brominated Flame Retardants by EPA Method 527 on Rxi-5Sil MS

GC_EV1215

Column: Rxi-5Sil MS, 15 m, 0.25 mm ID, 0.25 µm (cat.# 13620), using IP Deactivated Guard Column 5 m, 0.53 mm ID (cat.# 10045), with Universal Press-Tight Connectors (cat.# 20429)
Injector: Splitless
Detector: MS-TOF

Pesticides and Brominated Flame Retardants by EPA Method 527 on Rxi-5Sil MS

GC_EV1206

Column: Rxi-5Sil MS, 15 m, 0.25 mm ID, 0.25 µm (cat.# 13620), using IP Deactivated Guard Column 5 m, 0.53 mm ID (cat.# 10045), with Universal Press-Tight Connectors (cat.# 20429)
Injector: Splitless
Detector: MS-TOF

Detailed Hydrocarbons Analysis Rtx-DHA-100

GC_PC00743

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148), using Rtx-5 DHA tuning column, 2.62m, 0.25mm ID, 1.0μm (cat.# 10165)
Injector: Split
Detector: FID

Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA

GC_PC00774

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148), using Rtx-5 DHA tuning column* 2-5 m, 0.25 mm ID,
Injector: Split
Detector: FID

Haloacetic Acids by EPA 552.2 on Rtx-5

GC_EV00025

Column: Rtx-5, 30 m, 0.25 mm ID, 1.00 µm (cat.# 10253)
Injector: Split
Detector: ECD

Haloacetic Acids by EPA 552.2 on Rtx-200

GC_EV00026

Column: Rtx-200, 30 m, 0.25 mm ID, 1.00 µm (cat.# 15053)
Injector: Split
Detector: ECD

Cresylic Acids on Stabilwax-DA

GC_CH00277

Column: Stabilwax-DA, 30 m, 0.25 mm ID, 0.50 µm (cat.# 11038)
Injector: Split
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us