Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

APH[x]

Enter more terms to filter the results further.

Jet Fuel on Rxi-1ms by GC-VUV (ASTM D8267)

GC_PC1359

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: VUV

Determination Of Hydrocarbon Group Type in Gasoline on Rxi-1ms by GC-VUV (ASTM D8071)

GC_PC1358

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: VUV

Impurities in Commercial Cyclohexane on Rtx-DHA-100

GC_PC1356

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148)
Injector: Split
Detector: FID

Residual Pesticides in Botanicals by GC-MS/MS

GC_FS0568

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423), using Rxi guard column 5 m, 0.25 mm ID (cat.# 10029), with SilTite μ-Union connector kit (cat.# 23885)
Injector: Pulsed Splitless
Detector: Shimadzu GCMS TQ8040

4-Hr Shipping Facility Air Sample with radiello 145

GC_AR1171

Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916), with MXT low-dead-volume connector (cat.# 20536)
Injector: On-Column
Detector: MS-Scan

16-Hr Laboratory Air Sample with radiello 145

GC_AR1170

Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916), with MXT low-dead-volume connector (cat.# 20536)
Injector: On-Column
Detector: MS-Scan

PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14

GC_PC1330

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148)
Injector: Split
Detector: FID

16 Priority PAHs and Methylnaphthalenes on Rxi- 5Sil MS using the GC Accelerator Kit in a 208 V Oven

GC_EV1448

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-SIM

16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven

GC_EV1472

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-SIM

Naphthenes on Rtx-DHA-100 (ASTM D6729-14)

GC_PC1325

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148)
Injector: Split
Detector: FID

Alkylate Standard on Rtx-DHA 50 by Method D5134-13

GC_PC1319

Column: Rtx-DHA-50, 50 m, 0.20 mm ID, 0.50 µm (cat.# 10147)
Injector: Split
Detector: FID

Sulfur Compounds on Rtx-1

GC_PC1222

Column: Rtx-1, 30 m, 0.32 mm ID, 4.00 µm (cat.# 10198)
Injector: Split
Detector: Atomic emission detector (181 nm)

PAHs and PCB Congeners on Rxi-XLB

GC_EV1223

Column: Rxi-XLB, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13723)
Injector: Splitless
Detector: MS-Scan

EPA 8310 PAH Mix on Pinnacle II PAH (FLD)

LC_EV0522

Column: Pinnacle II PAH, custom (cat.# 921946E), Dimensions:150 mm x 3.0 mm ID, Particle Size: 4 µm, Pore Size: 110 Å, Temperature: 30 °C
Detector: Shimadzu RF-10AXL

Polycyclic Aromatic Hydrocarbons on Rtx-50

GC_EV00942

Column: Rtx-50, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10523)
Injector: Pulsed Splitless
Detector: MS-Scan

Polycyclic Aromatic Hydrocarbons on Rxi-17

GC_EV00924

Column: Rxi-17, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13523)
Injector: Pulsed Splitless
Detector: MS-Scan

Polycyclic Aromatic Hydrocarbons on Rxi-17 column

GC_EV00925

Column: Rxi-17, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13523)
Injector: Pulsed Splitless
Detector: MS-Scan

Mass APH on Rxi-1ms

GC_AR1145

Column: Rxi-1ms, 60 m, 0.32 mm ID, 1.00 µm (cat.# 13357)
Injector: Splitless
Detector: MS-Scan

Chlorinated Pesticide Residues in Olive Oil Rtx-CLPesticides2

GC_FF01043

Column: Rtx-CLPesticides2, 30 m, 0.25 mm ID, 0.20 µm (cat.# 11323)
Injector: Splitless
Detector: MS-SIM

Polycyclic Aromatic Hydrocarbons Rxi-5Sil MS

GC_EV00970

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-SIM

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us