share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Aliphatic[x]

Enter more terms to filter the results further.

Aliphatic Amines on Stabilwax-DB

GC_PC1361

Column: Stabilwax-DB, 30 m, 0.53 mm ID, 1.00 µm (cat.# 10855)
Injector: Split
Detector: FID

NJ DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection

GC_EV1490

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Split
Detector: FID

MA DEP EPH Aliphatics on Rxi-5Sil MS

GC_EV1482

Column: Rxi-5Sil MS, 30 m, 0.32 mm ID, 0.25 µm (cat.# 13624)
Injector: Splitless
Detector: FID

NJ DEP EPH Aliphatics on Rxi-5Sil MS

GC_EV1485

Column: Rxi-5Sil MS, 30 m, 0.32 mm ID, 0.25 µm (cat.# 13624)
Injector: Splitless
Detector: FID

MA DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection

GC_EV1488

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Split
Detector: FID

Aromatics, Aliphatics on 10% TCEP 100/120 Chromosorb® PAW

GC_PC00217

Column: SilcoSmooth™ Tubing, 100/120 mesh on Chromosorb® PAW, 2.5m, 1/8in. OD, 2 mm ID
Injector: On-Column - Packed
Detector: FID

NJDEP EPH Aliphatic Fraction on Rtx-5

GC_EV1208

Column: Rtx-5, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10224)
Injector: Splitless
Detector: FID

NJDEP EPH Aromatics on Rtx-5

GC_EV1209

Column: Rtx-5, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10224)
Injector: Splitless
Detector: FID

Volatile Petroleum Hydrocarbons (VPH) Massachusetts Department of Environmental Protection on Rtx-502.2

GC_EV00063

Column: Rtx-502.2, 105 m, 0.53 mm ID, 3.0 µm (cat.# 10910)
Injector: Purge and Trap Split
Detector: PID and FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us