MA DEP EPH Aromatics on Rxi-5Sil MS

GC_EV1481

Column: Rxi-5Sil MS, 30 m, 0.32 mm ID, 0.25 µm (cat.# 13624)
Injector: Splitless
Detector: FID

NJ DEP EPH Aromatics on Rxi-5Sil MS

GC_EV1483

Column: Rxi-5Sil MS, 30 m, 0.32 mm ID, 0.25 µm (cat.# 13624)
Injector: Splitless
Detector: FID

MA DEP EPH Aromatics on Rxi-5Sil MS by Split Injection

GC_EV1487

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Split
Detector: FID

NJ DEP EPH Aromatics on Rxi-5Sil MS by Split Injection

GC_EV1489

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Split
Detector: FID

Common Dibenzo Pyrenes and Coronene on Rxi-PAH (60 m x 0.25 mm x 0.10)

GC_EV1425

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM

Resolution of Chrysene from Isobaric Interferences on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)

GC_EV1422

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM

Resolution of Indeno[123-cd]pyrene from Dibenz Anthracene Isomers on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)

GC_EV1424

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM

Resolution of Benzo Fluoranthene and Benzo Pyrene Isomers on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)

GC_EV1423

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM

Select PAHs on Rxi-PAH (60 m x 0.25 mm x 0.10 µm)

GC_EV1417

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM

EPA 8310 PAHs on Pinnacle II PAH by LC-UV

LC_EV0537

Column: Pinnacle II PAH (cat.# 921946E), Dimensions:150 mm x 3.0 mm ID, Particle Size: 4 µm, Pore Size: 110 Å, Temperature: 30 °C
Detector: Waters Acquity PDA

Automated Solvent Extraction of NIST SRM 1941b, Organics in Marine Sediment, on Rxi-PAH

GC_EV1395

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM

Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH

GC_EV1394

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM

Creosote Oil Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)

GC_EV1367

Column: Rxi-1HT, 15 m, 0.25 mm ID, 0.10 µm (cat.# 13950)
Injector: Split
Detector: FID

Creosote Oil Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)

GC_EV1368

Column: Rxi-1HT, 15 m, 0.25 mm ID, 0.10 µm (cat.# 13950)
Injector: Split
Detector: FID

Creosote Oil Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)

GC_EV1381

Column: Rxi-5HT, 15 m, 0.25 mm ID, 0.10 µm (cat.# 13905)
Injector: Split
Detector: FID

Explosives on Raptor ARC-18 by EPA Method 8330B

LC_EV0530

Column: Raptor ARC-18 (cat.# 9314A1E), Dimensions:100 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 35 °C
Detector: Shimadzu Prominence SPD-M20A Diode array

Explosives on Raptor Biphenyl by EPA Method 8330B

LC_EV0531

Column: Raptor Biphenyl (cat.# 9309A65), Dimensions:150 mm x 4.6 mm ID, Particle Size: 2.7 µm, Temperature: 35 °C
Detector: Shimadzu Prominence SPD-M20A Diode array

Riser Pipe Oil from Deepwater Horizon Oil Spill on Rxi-17Sil and Rxi-1HT (GCxGC-TOFMS)

GC_PC1252

Column: Rxi-17Sil MS 60 m, 0.25 mm ID, 0.10 µm (cat.# custom)Rxi-1HT 1 m, 0.25 mm ID, 0.10 µm (cat.# 13950)
Injector: Split
Detector: MS-TOF

Nitroaromatics by U.S. EPA Method 609 on Rtx-5

GC_EV00041

Column: Rtx-5, 15 m, 0.53 mm ID, 1.50 µm (cat.# 10267)
Injector: Split
Detector: FID

Explosives by EPA 8330B on Ultra C8 with Trident Direct Guard Column

LC_EV0526

Column: Ultra C8 (cat.# 9103565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 30 °C
Detector: Shimadzu Prominence SPD-M20A Diode array

Explosives by EPA 8330B on Ultra Aromax with Trident Direct Guard

LC_EV0527

Column: Ultra Aromax (cat.# 9127565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 35 °C
Detector: Shimadzu Prominence SPD-M20A Diode array

EPA 8310 PAH Mix on Pinnacle II PAH (FLD)

LC_EV0522

Column: Pinnacle II PAH, custom (cat.# 921946E), Dimensions:150 mm x 3.0 mm ID, Particle Size: 4 µm, Pore Size: 110 Å, Temperature: 30 °C
Detector: Shimadzu RF-10AXL

NJDEP EPH Aliphatic Fraction on Rtx-5

GC_EV1208

Column: Rtx-5, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10224)
Injector: Splitless
Detector: FID

NJDEP EPH Aromatics on Rtx-5

GC_EV1209

Column: Rtx-5, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10224)
Injector: Splitless
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us