Determination Of Hydrocarbon Group Type in Gasoline on Rxi-1ms by GC-VUV (ASTM D8071)

GC_PC1358

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: VUV

PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14

GC_PC1330

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148)
Injector: Split
Detector: FID

Aromatics on Rtx-DHA-100 (ASTM D6729-14)

GC_PC1323

Column: Rtx-DHA-100, 100 m, 0.25 mm ID, 0.50 µm (cat.# 10148)
Injector: Split
Detector: FID

Creosote Oil Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)

GC_EV1381

Column: Rxi-5HT, 15 m, 0.25 mm ID, 0.10 µm (cat.# 13905)
Injector: Split
Detector: FID

Riser Pipe Oil from Deepwater Horizon Oil Spill on Rxi-17Sil and Rxi-1HT (GCxGC-TOFMS)

GC_PC1252

Column: Rxi-17Sil MS 60 m, 0.25 mm ID, 0.10 µm (cat.# custom)Rxi-1HT 1 m, 0.25 mm ID, 0.10 µm (cat.# 13950)
Injector: Split
Detector: MS-TOF

Aromatics (Benzene/Toluene/Xylene) on Rtx-200

GC_PC00189

Column: Rtx-200, 30 m, 0.53 mm ID, 0.50 µm (cat.# 15040)
Injector: Direct
Detector: FID

Aromatics (Benzene/Toluene/Xylene) on MXT-WAX

GC_PC00188

Column: MXT-WAX, 30 m, 0.28 mm ID, 1.00 µm (cat.# 70654)
Injector: Split
Detector: FID

Aromatics (Benzene/Toluene/Xylene) on Rtx-502.2

GC_PC00190

Column: Rtx-502.2, 105 m, 0.53 mm ID, 3.00 µm (cat.# 10910)
Injector: Split
Detector: FID

Aromatics (Benzene/Toluene/Xylene) on Rtx-Wax

GC_PC00191

Column: Rtx-Wax, 30 m, 0.53 mm ID, 1.00 µm (cat.# 12455)
Injector: Direct
Detector: FID

Spark Ignition Fuel Aromatics D3606 Column Set

GC_PC00961

Column: nonpolar Rtx® -1 polymer 1.8 m, 2 mm ID,, and proprietary packing 4.9 m, 2 mm ID,
Injector: Direct
Detector: FID

Gasoline Aromatics on Rtx-1

GC_PC00215

Column: Rtx-1, 60 m, 0.25 mm ID, 1.00 µm (cat.# 10156)
Injector: Split
Detector: MS-Scan

Gasoline Aromatics on Rtx-1

GC_PC00214

Column: Rtx-1, 60 m, 0.25 mm ID, 1.00 µm (cat.# 10156)
Injector: Split
Detector: MS-Scan

Aromatics Stabilwax

GC_CH00309

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan

Aromatics Rtx-502.2

GC_CH00308

Column: Rtx-502.2, 105 m, 0.53 mm ID, 3.00 µm (cat.# 10910)
Injector: Split
Detector: MS-Scan

Separation of Ethanol and Aromatics from Paraffins in Gasoline with GCxGC on Rtx-DHA-150 and Stabilwax

GC_PC1227

Column: Rtx-DHA-150 150 m, 0.25 mm ID, 1.00 µm (cat.# 10149)Stabilwax 1 m, 0.18 mm ID, 0.18 µm (cat.# 15118)
Injector: Split
Detector: FID

Aromatics on Rt-TCEP

GC_PC00211

Column: Rt-TCEP, 60 m, 0.25 mm ID, 0.40 µm (cat.# 10999)
Injector: Split
Detector: FID

Aromatics, Aliphatics on 10% TCEP 100/120 Chromosorb® PAW

GC_PC00217

Column: SilcoSmooth™ Tubing, 100/120 mesh on Chromosorb® PAW, 2.5m, 1/8in. OD, 2 mm ID
Injector: On-Column - Packed
Detector: FID

Aromatics (Xylene Isomers plus Cumene) on 5% RT-1200/1.75% Bentone 34 on 100/120 Silcoport

GC_PC00192

Column: SilcoSmooth Tubing, 100/120 mesh on Silcoport W, 1.8m, 1/8in. OD, 2 mm ID (cat.# 80125-800)
Injector: Direct
Detector: FID

Aromatics (Xylene Isomers /BTEX) on 5% Rt-1200/5% Bentone 34 on 100/120 Silcoport

GC_PC00193

Column: SilcoSmooth Tubing, 100/120 mesh on Silcoport , 2m, 1/8in. OD, 2 mm ID (cat.# 80129-800)
Injector: Direct
Detector: FID

NJDEP EPH Aliphatic Fraction on Rtx-5

GC_EV1208

Column: Rtx-5, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10224)
Injector: Splitless
Detector: FID

NJDEP EPH Aromatics on Rtx-5

GC_EV1209

Column: Rtx-5, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10224)
Injector: Splitless
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us