share:

Restek Searchable Chromatogram Library

You've Selected:

Market Area:
Petroleum & Petrochemical
Clear All Selections

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

BTEX[x]

Enter more terms to filter the results further.

Aromatics (Benzene/Toluene/Xylene) on Rtx-200

GC_PC00189

Column: Rtx-200, 30 m, 0.53 mm ID, 0.50 µm (cat.# 15040)
Injector: Direct
Detector: FID

Aromatics (Benzene/Toluene/Xylene) on MXT-WAX

GC_PC00188

Column: MXT-WAX, 30 m, 0.28 mm ID, 1.00 µm (cat.# 70654)
Injector: Split
Detector: FID

Aromatics (Benzene/Toluene/Xylene) on Rtx-Wax

GC_PC00191

Column: Rtx-Wax, 30 m, 0.53 mm ID, 1.00 µm (cat.# 12455)
Injector: Direct
Detector: FID

Separation of Ethanol and Aromatics from Paraffins in Gasoline with GCxGC on Rtx-DHA-150 and Stabilwax

GC_PC1227

Column: Rtx-DHA-150 150 m, 0.25 mm ID, 1.00 µm (cat.# 10149)Stabilwax 1 m, 0.18 mm ID, 0.18 µm (cat.# 15118)
Injector: Split
Detector: FID

p- and m-Xylenes in Gasoline by GCxGC on Rtx-DHA-150 and Stabilwax

GC_PC1226

Column: Rtx-DHA-150 150 m, 0.25 mm ID, 1.00 µm (cat.# 10149)Stabilwax 1 m, 0.18 mm ID, 0.18 µm (cat.# 15118)
Injector: Split
Detector: FID

Aromatics (Xylene Isomers /BTEX) on 5% Rt-1200/5% Bentone 34 on 100/120 Silcoport

GC_PC00193

Column: SilcoSmooth Tubing, 100/120 mesh on Silcoport , 2m, 1/8in. OD, 2 mm ID (cat.# 80129-800)
Injector: Direct
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us