share:

Restek Searchable Chromatogram Library

You've Selected:

Market Area:
Environmental
Clear All Selections
Show Filters

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

OVI[x]

Enter more terms to filter the results further.

Polycyclic Aromatic Hydrocarbons (PAHs) in a Spring Creek Sediment Sample by GCxGC-TOFMS

GC_EV1356

Column: Rxi-PAH 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)Rxi-1HT 1 m, 0.25 mm ID, 0.10 µm (cat.# 13950)
Injector: Splitless
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1329

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1330

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1331

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1332

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1333

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3

GC_EV1297

Column: Rtx-VMS, 30 m, 0.25 mm ID, 1.40 µm (cat.# 19915)
Injector: Purge and Trap Split
Detector: MS-Scan

Stir Bar Sorptive Extraction Cleaned Up Sample - QuEChERS Extract of NIST SRM Mussel (Rxi-17Sil MS and Rxi-1ms, m/z 178)

GC_EV1232

Column: Rxi-17Sil MS 15 m, 0.25 mm ID, 0.25 µm (cat.# 14120)Rxi-1ms 0.7 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

Stir Bar Sorptive Extraction Cleaned Up Sample - QuEChERS Extract of NIST SRM Mussel (Rxi17Sil MS and Rxi-1ms)

GC_EV1231

Column: Rxi-17Sil MS 15 m, 0.25 mm ID, 0.25 µm (cat.# 14120)Rxi-1ms 0.7 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

GCxGC Contour Plot of Riser Pipe Oil in 2010 Gulf Oil Spill (Rxi-17Sil MS and Rxi-1ms)

GC_EV1230

Column: Rxi-17Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)Rxi-1ms 1.2 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

GCxGC Contour Plot of Riser Pipe Oil in 2010 Gulf Oil Spill (Rxi-17Sil MS and Rxi-1ms)

GC_EV1229

Column: Rxi-17Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)Rxi-1ms 1.2 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

Volatile Organics by EPA 8021 on Rtx-VRX

GC_EV00001

Column: Rtx-VRX, 75 m, 0.45 mm ID, 2.55 µm (cat.# 19309)
Injector: Purge and Trap Splitless
Detector: μGold Tandem PID/HALL 2000

Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2

GC_EV00419

Column: Rtx-502.2, 75 m, 0.45 mm ID, 2.55 µm (cat.# 10986), with Universal “Y” Press-Tight Connector (cat.# 20405)
Injector: Purge and Trap Splitless
Detector: µGold Tandem PID/Hall

Volatile Organics by EPA Method 502.2 on Rtx-502.2

GC_EV00005

Column: Rtx-502.2, 75 m, 0.45 mm ID, 2.55 µm (cat.# 10986)
Injector: Purge and Trap Splitless
Detector: μGold Tandem PID/HALL 2000

Volatile Organics Confirmational Analysis by EPA Method 502.2 on Rtx-1

GC_EV00006

Column: Rtx-1, 75 m, 0.45 mm ID, 2.55 µm (cat.# 10992)
Injector: Purge and Trap Splitless
Detector: μGold Tandem PID/HALL 2000

Polycyclic Aromatic Hydrocarbons on Rxi-17Sil MS

GC_EV1160

Column: Rxi-17Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)
Injector: Splitless
Detector: FID

Pesticides on Pinnacle DB Aqueous C18

LC_FF0479A

Column: Pinnacle DB Aqueous C18 (cat.# 9418252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.9 µm, Pore Size: 140 Å, Temperature: 35 °C
Detector: Applied Biosystems 4000 QTRAP® LC-MS/MS system

Pesticides on Pinnacle DB Aqueous C18

LC_FF0479B

Column: Pinnacle DB Aqueous C18 (cat.# 9418252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.9 µm, Pore Size: 140 Å, Temperature: 35 °C
Detector: Applied Biosystems 4000 QTRAP® LC-MS/MS system

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us