Restek Searchable Chromatogram Library
Show Filters
Enter a compound, synonym, CAS #, compound class, column name, or keyword below.
Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270
Ultrashort- Through Long-Chain and Alternative PFAS on Raptor Polar X
LC_EV0569

Column: Raptor Polar X (cat.# 9311A52), Dimensions:50 mm x 2.1 mm ID, Particle Size: 2.7 µm, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
EPA Method 537.1 on Raptor C18
LC_EV0560

Column: Raptor C18 (cat.# 9304A52), Dimensions:50 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Ultra-short Chain, Legacy, and Alternative PFAS on Raptor C18 in Reagent Water
LC_EV0555

Column: Raptor C18 (cat.# 9304A1E), Dimensions:100 mm x 3 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Perfluorinated Alkyl Acids (PFBS, PFOA, PFOS, and HFPO-DA/GenX) on Raptor C18 5 μm
LC_EV0553

Column: Raptor C18 (cat.# 9304552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Perfluorinated Alkyl Acids on Raptor C18 by LC-MS/MS for EPA Method 537
LC_EV0548

Column: Raptor C18 (cat.# 9304552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Perfluorinated Compounds (PFCs) on Raptor C18 (1.8 μm)
LC_EV0540

Column: Raptor C18 (cat.# 9304252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Perfluorinated Compounds (PFCs) on Raptor C18 (1.8 μm)
LC_EV0547

Column: Raptor C18 (cat.# 9304252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.8 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Perfluorooctanoic Acid (PFOA) and Perfluorooctanesulfonic Acid (PFOS) on Raptor C18 by LC-MS/MS
LC_EV0536

Column: Raptor C18 (cat.# 9304512), Dimensions:100 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.