Restek Searchable Chromatogram Library
Show Filters
Enter a compound, synonym, CAS #, compound class, column name, or keyword below.
Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270
EPA 8310 PAHs on Pinnacle II PAH by LC-UV
LC_EV0537

Column: Pinnacle II PAH (cat.# 921946E), Dimensions:150 mm x 3.0 mm ID, Particle Size: 4 µm, Pore Size: 110 Å, Temperature: 30 °C
Detector: Waters Acquity PDA
Detector: Waters Acquity PDA
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH (30 m x 0.25 mm ID x 0.10 µm df )
GC_EV1397

Column: Rxi-PAH, 30 m, 0.25 mm ID, 0.10 µm (cat.# 49318)
Injector: Split
Detector: MS-SIM
Injector: Split
Detector: MS-SIM
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH
GC_EV1394

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-SIM
Injector: Split
Detector: MS-SIM
Detailed Analysis of Polycyclic Aromatic Hydrocarbons (PAHs) in Creosote Oil on Rxi-PAH
GC_EV1391

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: MS-Scan
Injector: Split
Detector: MS-Scan
Polycyclic Aromatic Hydrocarbons (PAHs) in a Spring Creek Sediment Sample by GCxGC-TOFMS
GC_EV1356

Column: Rxi-PAH 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)Rxi-1HT 1 m, 0.25 mm ID, 0.10 µm (cat.# 13950)
Injector: Splitless
Detector: TOFMS
Injector: Splitless
Detector: TOFMS
Polycyclic Aromatic Hydrocarbons on Rtx-50
GC_EV00942

Column: Rtx-50, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10523)
Injector: Pulsed Splitless
Detector: MS-Scan
Injector: Pulsed Splitless
Detector: MS-Scan
Polycyclic Aromatic Hydrocarbons on Rxi-17Sil MS
GC_EV1160

Column: Rxi-17Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)
Injector: Splitless
Detector: FID
Injector: Splitless
Detector: FID
Polycyclic Aromatic Hydrocarbons on Rxi-17
GC_EV00924

Column: Rxi-17, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13523)
Injector: Pulsed Splitless
Detector: MS-Scan
Injector: Pulsed Splitless
Detector: MS-Scan
Polycyclic Aromatic Hydrocarbons on Rxi-17 column
GC_EV00925

Column: Rxi-17, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13523)
Injector: Pulsed Splitless
Detector: MS-Scan
Injector: Pulsed Splitless
Detector: MS-Scan
Polycyclic Aromatic Hydrocarbons on Rxi-17 (15m x 0.25mm x 0.25µm)
GC_EV1181

Column: Rxi-17, 15 m, 0.25 mm ID, 0.25 µm (cat.# 13520)
Injector: Split
Detector: FID
Injector: Split
Detector: FID
Polycyclic Aromatic Hydrocarbons on Rxi-17Sil MS (15m x 0.25mm x 0.25µm)
GC_EV1186

Column: Rxi-17Sil MS, 15 m, 0.25 mm ID, 0.25 µm (cat.# 14120)
Injector: Split
Detector: FID
Injector: Split
Detector: FID
Polycyclic Aromatic Hydrocarbons by EPA Method 610 on Rxi-5ms
GC_EV00824

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Splitless
Detector: MS-Scan
Injector: Splitless
Detector: MS-Scan
EPA Method 610 Polycyclic Aromatic Hydrocarbons on Pinnacle DB PAH
LC_EV0469

Column: Pinnacle DB PAH (cat.# 9470252), Dimensions:50 mm x 2.1 mm ID, Particle Size: 1.9 µm, Pore Size: 140 Å, Temperature: 30 °C
Detector: Jasco X-LC 3075UV Variable Wavelength
Detector: Jasco X-LC 3075UV Variable Wavelength
Polycyclic Aromatic Hydrocarbons Infant Formula With and Without QuEChERS dSPE Cleanup on Rxi-5Sil MS
GC_FF01122

Column: Rxi®-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-Scan
Injector: Splitless
Detector: MS-Scan
Polycyclic Aromatic Hydrocarbons Infant Formula with and without QuEChERS dSPE Clean-up on Rxi-5Sil MS
GC_FF01123

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-SIM
Injector: Splitless
Detector: MS-SIM
Polycyclic Aromatic Hydrocarbons by EPA 610 on Rxi-5ms
GC_EV00825

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Direct
Detector: MS-Scan
Injector: Direct
Detector: MS-Scan
Polycyclic Aromatic Hydrocarbons Rxi-5Sil MS
GC_EV00970

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-SIM
Injector: Pulsed Splitless
Detector: MS-SIM
Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.