share:

Restek Searchable Chromatogram Library

Show Filters

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Potato[x]

Enter more terms to filter the results further.

Acrylamide Extracted from Potato Chips on Allure Acrylamide

LC_FS0530

Column: Allure Acrylamide (cat.# 9167552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 60 Å, Temperature: 22 °C
Detector: MS/MS

Pesticides on Sweet Potato With and Without QuEChERS dSPE Cleanup on Rxi-5Sil MS

GC_FF01125_1127

Column: Rxi-5Sil MS, 20 m, 0.18 mm ID, 0.18 µm (cat.# 43602)
Injector: Splitless
Detector: MS-TOF

Acrylamide (Potato Chip Extract) on Stabilwax

GC_FF00643

Column: Stabilwax, 15 m, 0.53 mm ID, 0.50 µm (cat.# 10637)
Injector: Splitless
Detector: FID

Pesticides in QuEChERS Extract of Sweet Potato on Rxi-5Sil MS

GC_FF01133

Column: Rxi®-5Sil MS, 20 m, 0.18 mm ID, 0.18 µm (cat.# 43602)
Injector: Splitless
Detector: TOFMS

Pesticides in QuEChERS Extract of Sweet Potato on Rxi-5Sil MS

GC_FF1125

Column: Rxi®-5Sil MS, 20 m, 0.18 mm ID, 0.18 µm (cat.# 43602)
Injector: Splitless
Detector: TOFMS

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us