Restek Searchable Chromatogram Library
Show Filters
Enter a compound, synonym, CAS #, compound class, column name, or keyword below.
Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270
GC Amenable Pesticides Regulated by California in Gummy Edibles on Rxi-5ms
GC_GN1207

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Splitless
Detector: MS/MS
Injector: Splitless
Detector: MS/MS
Comparison of Incurred Fludioxonil in Various Parts of Orange on Rxi-5ms
GC_FS0570

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Splitless
Detector: TSQ 8000
Injector: Splitless
Detector: TSQ 8000
GC Amenable Pesticides Regulated by California in Brownies on Rxi-5ms
GC_GN1206

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Splitless
Detector: MS/MS
Injector: Splitless
Detector: MS/MS
GCxGC-TOFMS Analysis of Unfortified Tobacco Extract After QuEChERS Extraction and dSPE Cleanup With 25 mg PSA and 7.5 mg GCB
GC_FF1242

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.3 m, 0.25 mm ID, 0.25 µm (cat.# 15124)
Injector: Splitless
Detector: MS-TOF
Injector: Splitless
Detector: MS-TOF
Pesticide Residue Analysis in Kale by LC-MS/MS on Ultra Aqueous C18
LC_FF0516

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å, Temperature: 50 °C
Detector: ABSCIEX MS/MS
Detector: ABSCIEX MS/MS
Incurred Pesticides in Red Bell Pepper QuEChERS Extract on Ultra Aqueous C18
LC_FF0515

Column: Ultra Aqueous C18 (cat.# 9178312), Dimensions:100 mm x 2.1 mm ID, Particle Size: 3 µm, Pore Size: 100 Å
Detector: AB SCIEX API 4000 LC/MS/MS System
Detector: AB SCIEX API 4000 LC/MS/MS System
GCxGC-TOFMS Chromatogram of QuEChERS Extract of Lemon Using Rxi-5Sil MS and Rtx-200
GC_FF1218

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.5 m, 0.18 mm ID, 0.20 µm (cat.# 45001)
Injector: Splitless
Detector: TOFMS
Injector: Splitless
Detector: TOFMS
GCxGC-TOFMS Chromatogram of QuEChERS Extract of Red Bell Pepper Showing Incurred Pesticides Using Rxi-5Sil MS and Rtx-200
GC_FF1219

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.5 m, 0.18 mm ID, 0.20 µm (cat.# 45001)
Injector: Splitless
Detector: TOFMS
Injector: Splitless
Detector: TOFMS
GCxGC-TOFMS Chromatogram of QuEChERS Extract of Red Bell Pepper Showing Incurred Pesticides Using Rxi-5Sil MS and Rtx-200
GC_FF1220

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.5 m, 0.18 mm ID, 0.20 µm (cat.# 45001)
Injector: Splitless
Detector: TOFMS
Injector: Splitless
Detector: TOFMS
GCxGC-TOFMS Chromatogram of QuEChERS Extract of Black Seedless Grapes Using Rxi-5Sil MS and Rtx-200
GC_FF1217

Column: Rxi-5Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)Rtx-200 1.5 m, 0.18 mm ID, 0.20 µm (cat.# 45001)
Injector: Splitless
Detector: TOFMS
Injector: Splitless
Detector: TOFMS
Pesticides on Sweet Potato With and Without QuEChERS dSPE Cleanup on Rxi-5Sil MS
GC_FF01125_1127

Column: Rxi-5Sil MS, 20 m, 0.18 mm ID, 0.18 µm (cat.# 43602)
Injector: Splitless
Detector: MS-TOF
Injector: Splitless
Detector: MS-TOF
QuEChERS Extract of Cannabis on Rxi-17Sil MS and Rxi-5ms by GCxGC-TOFMS (Zoomed in on cannabinoids region)
GC_FF1209

Column: Rxi-17Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)Rxi-5ms 0.9 m, 0.18 mm ID, 0.18 µm,
Injector: Split
Detector: TOFMS
Injector: Split
Detector: TOFMS
QuEChERS Extract of Cannabis on Rxi-17Sil MS and Rxi-5ms by GCxGC-TOFMS (Zoomed in on terpenes region)
GC_FF1208

Column: Rxi-17Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)Rxi-5ms 0.9 m, 0.18 mm ID, 0.18 µm,
Injector: Split
Detector: TOFMS
Injector: Split
Detector: TOFMS
QuEChERS Extract of Cannabis on Rxi-17Sil MS and Rxi-5ms by GCxGC-TOFMS
GC_FF1207

Column: Rxi-17Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)Rxi-5ms 0.9 m, 0.18 mm ID, 0.18 µm,
Injector: Split
Detector: TOFMS
Injector: Split
Detector: TOFMS
Polycyclic Aromatic Hydrocarbons Infant Formula With and Without QuEChERS dSPE Cleanup on Rxi-5Sil MS
GC_FF01122

Column: Rxi®-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-Scan
Injector: Splitless
Detector: MS-Scan
Polycyclic Aromatic Hydrocarbons Infant Formula with and without QuEChERS dSPE Clean-up on Rxi-5Sil MS
GC_FF01123

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-SIM
Injector: Splitless
Detector: MS-SIM
Comparison of Strawberry Extracts (TICs) Processed with Different QuEChERS dSPE Sorbents on Rxi-5Sil MS
GC_FF1199

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-Scan
Injector: Splitless
Detector: MS-Scan
Comparison of Spinach Extracts (TICs) Processed with Different QuEChERS dSPE Sorbents on Rxi-5Sil MS
GC_FF1200

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-Scan
Injector: Splitless
Detector: MS-Scan
Extracted Ion Chromatograms and Spectra for Incurred Pesticides in Strawberries on Rxi-5Sil MS
GC_FF1201

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-Scan
Injector: Splitless
Detector: MS-Scan
Pesticides in QuEChERS Extract of Sweet Potato on Rxi-5Sil MS
GC_FF01133

Column: Rxi®-5Sil MS, 20 m, 0.18 mm ID, 0.18 µm (cat.# 43602)
Injector: Splitless
Detector: TOFMS
Injector: Splitless
Detector: TOFMS
Pesticides in QuEChERS Extract of Sweet Potato on Rxi-5Sil MS
GC_FF1125

Column: Rxi®-5Sil MS, 20 m, 0.18 mm ID, 0.18 µm (cat.# 43602)
Injector: Splitless
Detector: TOFMS
Injector: Splitless
Detector: TOFMS
dSPE vs. cSPE Sample Cleanup of Dandelion Root Powder (Dietary Supplement) on Rxi-5Sil MS
GC_FF1171

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-Scan
Injector: Splitless
Detector: MS-Scan
Carfentrazone Ethyl in Dandelion Root Powder (Dietary Supplement) on Rxi-5Sil MS
GC_FF1172

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Splitless
Detector: MS-Scan
Injector: Splitless
Detector: MS-Scan
Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.