Restek Searchable Chromatogram Library

Show Filters

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

TNB[x]

Enter more terms to filter the results further.

Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270

GC_EV1357

Column: Rtx-5 w/ 5 m Integra-Guard, 30 m, 0.25 mm ID, 0.50 µm (cat.# 10238-124)
Injector: Pulsed Splitless
Detector: MS-Scan

Explosives on Raptor ARC-18 by EPA Method 8330B

LC_EV0530

Column: Raptor ARC-18 (cat.# 9314A1E), Dimensions:100 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 35 °C
Detector: Shimadzu Prominence SPD-M20A Diode array

Explosives on Raptor Biphenyl by EPA Method 8330B

LC_EV0531

Column: Raptor Biphenyl (cat.# 9309A65), Dimensions:150 mm x 4.6 mm ID, Particle Size: 2.7 µm, Temperature: 35 °C
Detector: Shimadzu Prominence SPD-M20A Diode array

9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D

GC_EV1328

Column: Rxi-5ms, 10 m, 0.18 mm ID, 0.18 µm, using Rxi-5ms 2 m, 0.18 mm ID,, with 0.4 mm OD matched press-fit, BGB (cat.# 2525LD)
Injector: Split
Detector: MS-Scan

Semivolatiles With Appendix IX on Rxi-5ms by 8270D

GC_EV1304

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan

Aromatics on Raptor Biphenyl

LC_GN0546

Column: Raptor Biphenyl (cat.# 9309A55), Dimensions:50 mm x 4.6 mm ID, Particle Size: 2.7 µm, Temperature: 40 °C
Detector: Waters Acquity PDA

0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270

GC_EV1269

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan

Explosives by EPA 8330B on Ultra C8 with Trident Direct Guard Column

LC_EV0526

Column: Ultra C8 (cat.# 9103565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 30 °C
Detector: Shimadzu Prominence SPD-M20A Diode array

Explosives by EPA 8330B on Ultra Aromax with Trident Direct Guard

LC_EV0527

Column: Ultra Aromax (cat.# 9127565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 35 °C
Detector: Shimadzu Prominence SPD-M20A Diode array

Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270

GC_EV1246

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan

Explosives by U.S. EPA Method 8095 Rxi-5ms with PTV On-Column Liner

GC_EV01041

Column: Rxi-5ms, 6 m, 0.53 mm ID, 0.5 µm (cat.# 563153), using IP deactivated guard column 5 m, 0.53 mm ID (cat.# 10045)
Injector: PTV Splitless
Detector: Micro-ECD

Improve Sensitivity with Larger Injection Volumes using a PTV On-Column Liner

GC_EV01042

Column: Rtx-TNT1, 6 m, 0.53 mm ID, 0.5 µm (cat.# 562719), using IP deactivated guard column 5 m, 0.53 mm ID (cat.# 10045)
Injector: PTV Splitless
Detector: Micro-ECD

Explosives by EPA Method 8095 on Rtx-TNT

GC_EV00406

Column: Rtx-TNT, 6 m, 0.53 mm ID, 1.50 µm (cat.# 12998)
Injector: Direct
Detector: ECD

Explosives US EPA Method 8095 Rtx-TNT2

GC_EV00407

Column: Rtx-TNT2, 6 m, 0.53 mm ID, 1.50 µm (cat.# 12999)
Injector: Direct
Detector: ECD

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us