Restek Searchable Chromatogram Library

You've Selected:

Market Area:
Petroleum & Petrochemical
Clear All Selections

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

TOFMS[x]

Enter more terms to filter the results further.

Other PAHs in a QuEChERS Extract of Mate Tea on Rxi-PAH

GC_FF1246

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Splitless
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1329

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1330

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1331

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

PAHs in Sediment Extract on Rxi-PAH (Sampled From Spring Creek, PA)

GC_EV1332

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Split
Detector: TOFMS

Benzo[b]fluoranthene and Benzo[a]pyrene in a QuEChERS Extract of Mate Tea Separated from Potential Interfering PAHs on Rxi-PAH

GC_FF1245

Column: Rxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
Injector: Splitless
Detector: TOFMS

Riser Pipe Oil from Deepwater Horizon Oil Spill on Rxi-17Sil and Rxi-1HT (GCxGC-TOFMS)

GC_PC1252

Column: Rxi-17Sil MS 60 m, 0.25 mm ID, 0.10 µm (cat.# custom)Rxi-1HT 1 m, 0.25 mm ID, 0.10 µm (cat.# 13950)
Injector: Split
Detector: MS-TOF

Stir Bar Sorptive Extraction Cleaned Up Sample - QuEChERS Extract of NIST SRM Mussel (Rxi-17Sil MS and Rxi-1ms, m/z 178)

GC_EV1232

Column: Rxi-17Sil MS 15 m, 0.25 mm ID, 0.25 µm (cat.# 14120)Rxi-1ms 0.7 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

Dibenzothiophene (Including C1-C4 Substitution) Elution Area for a Diesel Sample on Rxi-1ms and Rtx-FLD (Surface Plot, GCxGC-TOFMS, Extracted Ions)

GC_PC1210

Column: Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326),  with Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326)Rtx-FLD 1.5 m, 0.25 mm ID, 0.10 µm,
Injector: Split
Detector: TOFMS

Dibenzothiophene (Including C1-C4 Substitution) Elution Area for a Diesel Sample on Rxi-1ms and Rtx-FLD (Surface Plot, GCxGC-TOFMS, TIC)

GC_PC1209

Column: Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326),  with Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326)Rtx-FLD 1.5 m, 0.25 mm ID, 0.10 µm,
Injector: Split
Detector: TOFMS

Diesel on Rxi-1ms and Rtx-FLD (GCxGC-TOFMS, TIC)

GC_PC1203

Column: Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326),  with Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326)Rtx-FLD 1.5 m, 0.25 mm ID, 0.10 µm,
Injector: Split
Detector: TOFMS

Dibenzothiophene (Including C1-C4 Substitution) Elution Area for a Diesel Sample on Rxi-1ms and Rtx-FLD (GCxGC-TOFMS, TIC)

GC_PC1204

Column: Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326),  with Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326)Rtx-FLD 1.5 m, 0.25 mm ID, 0.10 µm,
Injector: Split
Detector: TOFMS

Dibenzothiophene (Including C1-C4 Substitution) Elution Area for a Diesel Sample on Rxi-1ms and Rtx-FLD (GCxGC-TOFMS, Extracted Ions)

GC_PC1205

Column: Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326),  with Rxi-1ms 60 m, 0.25 mm ID, 0.25 µm (cat.# 13326)Rtx-FLD 1.5 m, 0.25 mm ID, 0.10 µm,
Injector: Split
Detector: TOFMS

Stir Bar Sorptive Extraction Cleaned Up Sample - QuEChERS Extract of NIST SRM Mussel (Rxi17Sil MS and Rxi-1ms)

GC_EV1231

Column: Rxi-17Sil MS 15 m, 0.25 mm ID, 0.25 µm (cat.# 14120)Rxi-1ms 0.7 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

GCxGC Contour Plot of Riser Pipe Oil in 2010 Gulf Oil Spill (Rxi-17Sil MS and Rxi-1ms)

GC_EV1230

Column: Rxi-17Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)Rxi-1ms 1.2 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

GCxGC Contour Plot of Riser Pipe Oil in 2010 Gulf Oil Spill (Rxi-17Sil MS and Rxi-1ms)

GC_EV1229

Column: Rxi-17Sil MS 30 m, 0.25 mm ID, 0.25 µm (cat.# 14123)Rxi-1ms 1.2 m, 0.15 mm ID, 0.15 µm (cat.# 43800)
Injector: Splitless
Detector: TOFMS

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us