share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

Triglycerides[x]

Enter more terms to filter the results further.

Glycerol and Glycerides in Biodiesel on Rtx-Biodiesel TG (10 m) by ASTM D6584

GC_PC1368

Column: Rtx-Biodiesel TG with 2 m x 0.53 mm ID retention gap, 10 m, 0.32 mm ID, 0.1 µm (cat.# 10291)
Injector: Cool On-column
Detector: FID

Impurities in Biodiesel on Rtx-Biodiesel TG by ASTM D6584

GC_PC1367

Column: Rtx-Biodiesel TG with 2 m x 0.53 mm ID retention gap, 15 m, 0.32 mm ID, 0.1 µm (cat.# 10293)
Injector: Cool On-column
Detector: FID

Sunflower Oil on Rxi-65TG (30 m x 0.32 mm x 0.1 µm)

GC_FF1344

Column: Rxi-65TG, 30 m, 0.32 mm ID, 0.10 µm (cat.# 17109)
Injector: Split
Detector: FID

Cocoa Butter on Rxi-65TG (30 m x 0.32 mm x 0.1 µm)

GC_FF1345

Column: Rxi-65TG, 30 m, 0.32 mm ID, 0.10 µm (cat.# 17109)
Injector: Split
Detector: FID

Palm Oil on Rxi-65TG (30 m x 0.32 mm x 0.1 µm)

GC_FF1342

Column: Rxi-65TG, 30 m, 0.32 mm ID, 0.10 µm (cat.# 17109)
Injector: Split
Detector: FID

Extra Virgin Olive Oil on Rxi-65TG (30 m x 0.32 mm x 0.1 µm)

GC_FF1343

Column: Rxi-65TG, 30 m, 0.32 mm ID, 0.10 µm (cat.# 17109)
Injector: Split
Detector: FID

Rxi-65TG: High-Temperature Stability Overlay

GC_FF1287

Column: Rxi-65TG, 30 m, 0.25 mm ID, 0.1 µm (cat.# 17108)
Injector: Split
Detector: FID

Analysis of Glycerol, Mono-, Di-, and Triglycerides in Soy B100 by EN 14105 (2011)

GC_PC1335

Column: MXT-Biodiesel TG with 2 m x 0.53 mm ID retention gap, 15 m, 0.32 mm ID, 0.10 µm (cat.# 70291)
Injector: Cool On-column
Detector: FID

Biodiesel (B100) on MXT-Biodiesel TG by ASTM D6584

GC_PC1293

Column: MXT-Biodiesel TG with 2 m Integra-Gap (integrated retention gap), 16 m total length, 0.53 mm ID, 0.16 µm (cat.# 70289)
Injector: Cold On-column
Detector: FID

Derivatized B100 and Internal Standards on MXT-Biodiesel TG with 2m Integra Gap

GC_PC00934

Column: MXT-Biodiesel TG 13m, 0.53mm ID, 0.16µm with built-in 2m Integra-Gap (total column length 15 m)
Injector: Cold On-column
Detector: FID

Butter Triglycerides on Rtx-65TG

GC_FF00137

Column: Rtx-65TG, 30 m, 0.25 mm ID, 0.10 µm (cat.# 17008)
Injector: Cold On-column
Detector: FID

Egg Pasta Sterols & Glycerides on Rtx-65TG

GC_FF01046

Column: Rtx-65TG, 30 m, 0.25 mm ID, 0.10 µm (cat.# 17008)
Injector: PTV Split
Detector: FID

Glycerides and Cholesterol in Extracted Egg Fats on Rtx-65TG

GC_FF01045

Column: Rtx-65TG, 30 m, 0.25 mm ID, 0.10 µm (cat.# 17008)
Injector: Split
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us