share:

Restek Searchable Chromatogram Library

You've Selected:

Market Area:
Pharmaceutical
Clear All Selections

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

USP[x]

Enter more terms to filter the results further.

USP <467> Residual Solvents Class 3 MIx A on Rxi-624Sil MS

GC_PH1178

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Loop
Detector: FID

Residual Solvents Class 2 - Mix A (2013 Rev) on Stabilwax (G16)

GC_PH1177

Column: Stabilwax, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10624)
Injector: Headspace - Loop
Detector: FID

Residual Solvents Class 2 — Mix A on Rxi-624Sil MS (G43) by USP <467>

GC_PH1175

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Loop
Detector: FID

Dynamic Headspace USP <467> solvents on Rtx-1301 (G43)

GC_PH00811

Column: Rtx-1301 (G43), 30 m, 0.53 mm ID, 3.00 µm (cat.# 16085-126)
Injector: Headspace - Syringe Split
Detector: FID

Residual Solvents (Class 1) for Water-Soluble Articles on Rxi-624Sil MS

GC_PH1144

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Loop
Detector: FID

Class 1 Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS

GC_PH1145

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Loop
Detector: FID

Residual Solvents (Class 2 - Mixture A) for Water-Soluble Articles on Rxi-624Sil MS

GC_PH1146

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Loop
Detector: FID

Class 2 - Mix A Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS

GC_PH1147

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Loop
Detector: FID

Class 2 - Mix B Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS

GC_PH1149

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Loop
Detector: FID

USP <467> Residual Solvents on Rtx-1301 (G43) by Static Headspace

GC_PH00810

Column: Rtx-1301 w/5m Integra-Guard, 30 m, 0.53 mm ID, 3.00 µm (cat.# 16085-126)
Injector: Headspace - Loop
Detector: FID

Residual Solvents Class 1 on Rtx-624

GC_PH00909

Column: Rtx-624, 30 m, 0.32 mm ID, 1.80 µm (cat.# 10970)
Injector: Headspace - Loop
Detector: FID

Residual Solvents Class 2 Mixture A on Rtx-624

GC_PH00910

Column: Rtx-624, 30 m, 0.32 mm ID, 1.80 µm (cat.# 10970)
Injector: Headspace - Loop
Detector: FID

Residual Solvents Class 2 Mixture B on Rtx-624

GC_PH00911

Column: Rtx-624, 30 m, 0.32 mm ID, 1.80 µm (cat.# 10970)
Injector: Headspace - Loop
Detector: FID

Residual Solvents (Class 1) on Stabilwax (G16)

GC_PH00951

Column: Stabilwax, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10624)
Injector: Headspace - Syringe Split
Detector: FID

Residual Solvents (Class 2 - Mixture A) on Stabilwax (G16)

GC_PH00952

Column: Stabilwax, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10624)
Injector: Headspace - Syringe Split
Detector: FID

Residual Solvents (Class 2 - Mixture B) on Stabilwax (G16)

GC_PH00953

Column: Stabilwax, 30 m, 0.32 mm ID, 0.25 µm (cat.# 10624)
Injector: Headspace - Syringe Split
Detector: FID

Residual Solvents Rxi-624Sil MS

GC_PH01115

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Syringe Split
Detector: FID

Residual Solvents Rxi-624Sil MS

GC_PH01116

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Syringe Split
Detector: FID

Residual Solvents Rxi-624Sil MS

GC_PH01117

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Syringe Split
Detector: FID

Class 1 Residual Solvents for USP <467> Water-Soluble Articles on Rxi-624Sil MS

GC_PH1160

Column: Rxi-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Loop
Detector: FID

Competitor Comparison: Class 2 - Mix A Residual Solvents for USP <467> Water-Soluble Articles

GC_PH1161

Column: Rxi®-624Sil MS, 30 m, 0.32 mm ID, 1.80 µm (cat.# 13870)
Injector: Headspace - Loop
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us