Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set

GC_EV1498

Column: Rtx-CLPesticides 30 m, 0.32 mm ID, 0.32 µm (cat.# 11141-051), and Rtx-CLPesticides2 30 m, 0.32 mm ID, 0.25 µm (cat.# 11324-051), using Rxi guard column 5 m, 0.32 mm ID (cat.# 10039), with universal angled “Y” Press-Tight connector (cat.# 20403-261)
Injector: Splitless
Detector: Micro-ECD

Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set

GC_EV1496

Column: Rtx-CLPesticides 30 m, 0.25 mm ID, 0.25 µm (cat.# 11123-051), and Rtx-CLPesticides2 30 m, 0.25 mm ID, 0.20 µm (cat.# 11323-051), using Rxi guard column 5 m, 0.25 mm ID (cat.# 10029), with universal angled “Y” Press-Tight connector (cat.# 20403-261)
Injector: Splitless
Detector: Micro-ECD

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven

GC_EV1475

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-Scan

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven

GC_EV1476

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-Scan

16 Priority PAHs and Methylnaphthalenes on Rxi- 5Sil MS using the GC Accelerator Kit in a 208 V Oven

GC_EV1448

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-SIM

16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven

GC_EV1472

Column: Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816)
Injector: Split
Detector: MS-SIM

Mineral Spirits on Rxi-1ms

GC_PC01066

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: FID

99% Weathered Unleaded Gasoline on Rxi-1ms

GC_PC01070

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: FID

Unleaded Gasoline on Rxi-1ms

GC_PC01071

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: FID

50% Weathered Diesel Fuel #2 on Rxi-1ms

GC_PC00921

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.50 µm (cat.# 13338)
Injector: Split
Detector: FID

Unweathered Diesel Fuel #2 on Rxi-1ms

GC_PC00922

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.50 µm (cat.# 13338)
Injector: Split
Detector: FID

Ketones on Rt-QS-BOND

GC_PC01015

Column: Rt-QS-BOND, 30 m, 0.53 mm ID, 20 µm (cat.# 19738)
Injector: Split
Detector: FID

Refinery Gas Mix on Rt-QS-BOND

GC_PC01054

Column: Rt-QS-BOND, 30 m, 0.53 mm ID, 20 µm (cat.# 19738)
Injector: Split
Detector: FID

Unweathered Kerosene on Rxi-1ms

GC_PC01060

Column: Rxi-1ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13323)
Injector: Split
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us