share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

alcohols[x]

Enter more terms to filter the results further.

Naltrexone and 6-β-Naltrexol in Urine on Raptor Biphenyl by LC-MS/MS

LC_CF0588

Column: Raptor Biphenyl (cat.# 9309552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: MS/MS

Sugar Alcohols (TMS derivatives) 3% Rt-101 on 100/120 Silcoport

GC_FF00130

Column: 3% Rt-101 on 100/120 Silcoport, 2m, 1/8in. OD, 2 mm ID (cat.# 80400)
Injector: Splitless
Detector: FID

Alcohols and Acetates on Stabilwax-MS

GC_FF1224

Column: Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 10673)
Injector: Split
Detector: MS-Scan

Alcohols Rtx-5

GC_CH00292

Column: Rtx-5, 60 m, 0.32 mm ID, 1.00 µm (cat.# 10257)
Injector: Split
Detector: FID

Alcohols Rtx-Volatiles

GC_CH00293

Column: Rtx-Volatiles, 60 m, 0.32 mm ID, 1.50 µm (cat.# 10904)
Injector: Split
Detector: FID

Alcohols Stabilwax

GC_CH00288A

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan

Alcohols Stabilwax

GC_CH00288B

Column: Stabilwax, 60 m, 0.53 mm ID, 1.00 µm (cat.# 10658)
Injector: Split
Detector: MS-Scan

Alcohols on Rtx-502.2

GC_CH00290

Column: Rtx-502.2, 105 m, 0.53 mm ID, 3.00 µm (cat.# 10910)
Injector: Split
Detector: MS-Scan

Alcohols on Rtx-502.2

GC_CH00291

Column: Rtx-502.2, 105 m, 0.53 mm ID, 3.00 µm (cat.# 10910)
Injector: Split
Detector: MS-Scan

Blood Alcohol Analysis on Rtx-BAC Plus 2

GC_CF1154

Column: Rtx-BAC Plus 2, 30 m, 0.32 mm ID, 0.6 µm (cat.# 18006)
Injector: Headspace - Loop
Detector: FID

Blood Alcohol Analysis on Rtx-BAC Plus 1

GC_CF1153

Column: Rtx-BAC Plus 1, 30 m, 0.32 mm ID, 1.8 µm (cat.# 18004)
Injector: Headspace - Loop
Detector: FID

Scotch on Rtx-1301

GC_FF00112

Column: Rtx-1301, 60 m, 0.25 mm ID, 1.40 µm (cat.# 16016)
Injector: Split
Detector: FID

Scotch on CarboBlack B

GC_FF00113

Column: SilcoSmooth™ Tubing, 80/120 mesh on CarboBlack B, 2m, 1/8in. OD, 2 mm ID (cat.# 80105-800)
Injector: On-Column - Packed
Detector: FID

Underivatized Alcoholic Beverage Acids and Methyl Esters on Stabilwax-DA

GC_FF00500

Column: Stabilwax-DA, 30 m, 0.18 mm ID, 0.18 µm
Injector: Splitless
Detector: FID

Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS

GC_EV00423

Column: Rtx-VMS, 60 m, 0.45 mm ID, 2.55 µm (cat.# 19909)
Injector: Purge and Trap Split
Detector: MS-Scan

Amines/Alcohols/Chlorides on Stabilwax

GC_CH00307

Column: Stabilwax, 30 m, 0.53 mm ID, 0.25 µm (cat.# 10625)
Injector: Split
Detector: FID

Water and Ethanol in Acetone on Rt-Q-BOND

GC_PC01075

Column: Rt-Q-BOND, 30 m, 0.53 mm ID, 20 µm (cat.# 19742)
Injector: Split
Detector: TCD

Solvents on MXT-Q-BOND

GC_PC1184

Column: MXT-Q-BOND, 30 m, 0.53 mm ID, 20 µm (cat.# 79716)
Injector: Split
Detector: FID

Volatile Organics by EPA 8260B on Rtx-VMS

GC_EV00427

Column: Rtx-VMS, 60 m, 0.25 mm ID, 1.40 µm (cat.# 19916)
Injector: Purge and Trap Split
Detector: MS-Scan

Blood Alcohol on Rtx-BAC1 & Rtx-BAC2 (0.53mm ID columns)

GC_PH00239

Column: Rtx-BAC1 30 m, 0.53 mm ID, 3.00 µm (cat.# 18001), and Rtx-BAC2 30 m, 0.53 mm ID, 2.00 µm (cat.# 18000)
Injector: Headspace - Syringe Split
Detector: FID

Blood Alcohol on Rtx-BAC1 & Rtx-BAC2 (0.32mm ID Columns)

GC_PH00241

Column: Rtx-BAC1 30 m, 0.32 mm ID, 1.80 µm (cat.# 18003), and Rtx-BAC2 30 m, 0.32 mm ID, 1.20 µm (cat.# 18002), using two hole ferrule
Injector: Headspace - Syringe Split
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us