Multiclass Veterinary Antibiotics on Raptor C18 by LC-MS/MS
LC_FS0506

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 35 °C
Detector: MS/MS
Detector: MS/MS
Macrolide, Lincosamide, and Streptogramin Antibiotics on Raptor C18 by LC-MS/MS
LC_FS0502

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Amphenicol and Tetracycline Antibiotics on Raptor C18 by LC-MS/MS
LC_FS0504

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Quinolone Antibiotics on Raptor C18 by LC-MS/MS
LC_FS0505

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Penicillin, Cephalosporin, and Tetracycline Antibiotics on Raptor C18 by LC-MS/MS
LC_FS0500

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Ionophore Antibiotics on Raptor Biphenyl by LC-MS/MS
LC_FS0503

Column: Raptor Biphenyl (cat.# 9309A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Sulfonamide Antibiotics on Raptor C18 by LC-MS/MS
LC_FS0501

Column: Raptor C18 (cat.# 9304A12), Dimensions:100 mm x 2.1 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Macrolide Antibiotics on Raptor C18 by LC-MS/MS
LC_CF0600

Column: Raptor C18 (cat.# 9304512), Dimensions:100 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 90 Å, Temperature: 40 °C
Detector: MS/MS
Detector: MS/MS
Sulfur Antibiotics on Raptor Biphenyl
LC_FF0530

Column: Raptor Biphenyl (cat.# 9309A5E), Dimensions:50 mm x 3.0 mm ID, Particle Size: 2.7 µm, Temperature: 20 °C
Detector: Waters Acquity PDA
Detector: Waters Acquity PDA
Sulfur Antibiotics by UHPLC on Pinnacle DB Biphenyl
LC_GN0532

Column: Pinnacle DB Biphenyl (cat.# 9409212), Dimensions:100 mm x 2.1 mm ID, Particle Size: 1.9 µm, Pore Size: 140 Å, Temperature: 25 °C
Detector: Shimadzu Prominence SPD-M20A Diode array
Detector: Shimadzu Prominence SPD-M20A Diode array
Antibiotic Cephradine on Ultra IBD (LC/MS)
LC_0125

Column: Ultra IBD (cat.# 9175552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: Ambient
Detector: PE/Sciex API 150 EX
Detector: PE/Sciex API 150 EX
Antibiotic Cephaloridine on Ultra IBD (LC/MS)
LC_0124

Column: Ultra IBD (cat.# 9175552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: Ambient
Detector: PE/Sciex API 150 EX
Detector: PE/Sciex API 150 EX
16 hr Laboratory Air Sample with radiello 165
LC_GN0531

Column: Raptor C18 (cat.# 9304A65), Dimensions:150 mm x 4.6 mm ID, Particle Size: 2.7 µm, Pore Size: 90 Å, Temperature: 30 °C
Detector: UV/Vis
Detector: UV/Vis
Antibiotic Penicillin V on Ultra IBD (LC/MS)
LC_0127

Column: Ultra IBD (cat.# 9175552), Dimensions:50 mm x 2.1 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: Ambient
Detector: PE/Sciex API 150 EX
Detector: PE/Sciex API 150 EX
Antibiotic Cephaloridine on Ultra IBD (Normal Phase)
LC_0101

Column: Ultra IBD (cat.# 9175565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 27 °C
Detector: UV/Vis
Detector: UV/Vis
Antibiotic Cephaloridine on Ultra IBD (Reversed Phase)
LC_0102

Column: Ultra IBD (cat.# 9175565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 27 °C
Detector: UV/Vis
Detector: UV/Vis
Antibiotic Penicillin V on Ultra IBD
LC_0096

Column: Ultra IBD (cat.# 9175565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 30 °C
Detector: UV/Vis
Detector: UV/Vis
Antibiotic Amoxicillin on Ultra IBD
LC_0095

Column: Ultra IBD (cat.# 9175565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 30 °C
Detector: UV/Vis
Detector: UV/Vis
Antibiotic Cephalexin on Ultra IBD
LC_0094

Column: Ultra IBD (cat.# 9175565), Dimensions:150 mm x 4.6 mm ID, Particle Size: 5 µm, Pore Size: 100 Å, Temperature: 30 °C
Detector: UV/Vis
Detector: UV/Vis
Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.