share:

Restek Searchable Chromatogram Library

Show Filters

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

appendix[x]

Enter more terms to filter the results further.

Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270

GC_EV1357

Column: Rtx-5 w/ 5 m Integra-Guard, 30 m, 0.25 mm ID, 0.50 µm (cat.# 10238-124)
Injector: Pulsed Splitless
Detector: MS-Scan

Combination Run of U.S. EPA Methods 521 and 522, Nitrosamines and 1,4-Dioxane, on Rxi-5Sil-MS by CSR-LVSI

GC_EV1334

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 1.00 µm (cat.# 13653), using Rxi guard column 10 m, 0.53 mm ID (cat.# 10073), with SGE µ-union
Injector: Splitless
Detector: MS-SIM

9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D

GC_EV1328

Column: Rxi-5ms, 10 m, 0.18 mm ID, 0.18 µm, using Rxi-5ms 2 m, 0.18 mm ID,, with 0.4 mm OD matched press-fit, BGB (cat.# 2525LD)
Injector: Split
Detector: MS-Scan

Semivolatiles With Appendix IX on Rxi-5ms by 8270D

GC_EV1304

Column: Rxi-5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423)
Injector: Split
Detector: MS-Scan

0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270

GC_EV1269

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan

Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270

GC_EV1246

Column: Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623)
Injector: Pulsed Splitless
Detector: MS-Scan

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us