share:

Restek Searchable Chromatogram Library

Enter a compound, synonym, CAS #, compound class, column name, or keyword below.

Examples:
1,4-dioxane
123-91-1, pyrene and chrysene
semivolatiles and rxi5silms
8270

You are currently filtering on:

CFC[x]

Enter more terms to filter the results further.

Volatile Organics US EPA Method 8260B on Rtx-VMS

GC_EV00640

Column: Rtx-VMS, 40 m, 0.18 mm ID, 1.00 µm (cat.# 49915)
Injector: Purge and Trap Split
Detector: 5973 GC/MS w/ turbomolecular pump

Chlorofluorocarbons 5% Krytox on 60/80 CarboBlack B

GC_CH00323

Column: SilcoSmooth™ stainless steel tubing, 60/80 mesh on CarboBlack B, 3.05m, 1/8in. OD, 2.1 mm ID (cat.# Custom)
Injector: On-Column - Packed
Detector: FID

Freon 12 and Ethylene Oxide on Rtx-1

GC_CH00324

Column: Rtx-1, 30 m, 0.53 mm ID, 5.00 µm (cat.# 10179)
Injector: Split
Detector: FID

Freon 12 & Ethylene Oxide on Rtx-200

GC_CH00325

Column: Rtx-200, 30 m, 0.53 mm ID, 3.00 µm (cat.# 15085)
Injector: Direct
Detector: FID

Impurity Analysis of 1,1,1,2-Tetrafluoroethane (CFC-134a) on Rt-Alumina BOND/CFC

GC_GN1155

Column: Rt-Alumina BOND/CFC, 30 m, 0.53 mm ID (cat.# 19763)
Injector: Split
Detector: FID

Stability Test: Halogenated Hydrocarbons on Rt-Alumina BOND/CFC (Before & After 16 hrs. at 200 °C)

GC_PC1192

Column: Rt-Alumina BOND/CFC, 30 m, 0.53 mm ID, 10 µm (cat.# 19763)
Injector: Split
Detector: FID

Halogenated Hydrocarbons on Rt-Alumina BOND/CFC

GC_PC1193

Column: Rt-Alumina BOND/CFC, 30 m, 0.53 mm ID, 10 µm (cat.# 19763)
Injector: Split
Detector: FID

Chlorofluorocarbons (CFCs) on Rt-Alumina BOND/CFC

GC_PC1199

Column: Rt-Alumina BOND/CFC, 30 m, 0.53 mm ID, 10 µm (cat.# 19763)
Injector: Split
Detector: FID

Restek's searchable chromatogram library is a comprehensive database of hundreds of chromatograms from applications by Restek chemists, our partners, and customers. Our unique library allows you to search for a chromatogram by compound name, synonym, CAS #, compound class, Restek or competitor column name, catalog number, or keyword. You can add more search terms to refine your results, or use the links in the sidebar of the library to quickly narrow your result set. If you have any questions regarding any of the applications shown here, please feel free to contact Restek's Technical Service Group.

Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us